LARE Section 2 study materials
LARE Section 2 study resources

LARE Section 2 cheat sheet

LARE Section 2 · Keep the key ideas within reach.

Quick reference

Inventory and Data Collection

  • Slope percent = (rise ÷ run) × 100; a 3-ft rise over 60 ft of run is a 5% slope.

  • Contour interval rule: 1–2 ft on slopes under 2%, 5 ft on rolling terrain, 10 ft on steep sites; smaller intervals on flat land reveal drainage patterns.

  • Scale selection: 1"=10' or 1"=20' for design details, 1"=40' to 1"=100' for site plans, and 1:24,000 for USGS base mapping.

  • DBH is measured 4.5 ft above grade on the uphill side; critical root zone radius is commonly estimated at 1 ft per inch of DBH (some specifications use 1.5 ft).

  • Web Soil Survey (SSURGO) reports drainage class, depth to seasonal high water table, hydric soil rating, and shrink-swell potential for preliminary planning.

  • Call 811 or the local one-call service before subsurface work; utility locations belong on the base map with horizontal and vertical datum notes.

  • NAVD88 is the current vertical datum; NGVD29 survey data must be converted before combining it with new survey information.

  • Summer solstice noon sun altitude = 90° − latitude + 23.5°; winter solstice altitude = 90° − latitude − 23.5°.

Quick reference

Site Analysis and Synthesis

  • Slope classes: 0–3% flat with drainage limitations, 3–10% ideal for most development, 10–15% steep with grading cost limits, 15–25% severe, and over 25% generally unbuildable.

  • Rational method: Q = CiA, where C is the runoff coefficient (about 0.9 for pavement, 0.2 for lawn), i is rainfall intensity, and A is drainage area.

  • Aspect rule for the northern hemisphere: south- and west-facing slopes are warmer and drier; north- and east-facing slopes are cooler and moister; valleys collect cold air as frost pockets.

  • Suitability analysis: map each factor, assign weights, overlay the scores, then field-check the result before committing to a land-use plan.

  • Delineate watersheds by drawing lines perpendicular to contours along ridges and following flow paths to low points and outlets.

  • Stream and wetland buffers are set by local ordinance, commonly 25–100 ft of vegetated buffer; verify the jurisdiction rather than applying a default.

  • Viewshed check: sightline from eye height of 5–6 ft to the object; topographic screening works when an intervening ridge rises above that line.

  • Build an opportunities-and-constraints composite that separates developable ground from protectable resources before testing program fit.

Quick reference

Program Development and Site Planning

  • Program sequence: needs assessment → space list with square footages → adjacency matrix → bubble diagram → blocking and stacking → scaled test fit.

  • Parking module: 9' × 18' standard stall; 8' accessible stall with a 5' access aisle; 11' van-accessible stall with a 5' aisle; typically 24' for a two-way aisle and 12–14' for one-way.

  • ADA: accessible route running slope maximum 5%; ramp maximum 8.33% with landings every 30 inches of rise; 60-inch turning space; 36-inch minimum clear width.

  • Fire apparatus access is commonly 20 ft clear width, 13 ft 6 in vertical clearance, and a 25–50 ft inside turning radius; confirm with the local fire marshal.

  • Grading minima: 1% in swales and paved areas with positive flow, 2% for turf, and 5% maximum on accessible routes.

  • FAR = gross floor area ÷ lot area; impervious coverage = impervious area ÷ lot area × 100.

  • Guardrails are required at drops over 30 inches; retaining walls over 4 ft typically need engineered design and permits.

  • Setbacks, height limits, and lot coverage come from zoning; confirm them before layout because they often define the buildable envelope.

Quick reference

Design and Planning Communication

  • Construction set order: cover sheet, general notes, layout and demolition, grading, drainage and utilities, planting, details, and specifications.

  • Line weight hierarchy: heaviest for cut or section elements, medium for visible edges, light for background, thinnest for dimensions and notes.

  • Every plan sheet carries a title block, north arrow, graphic scale, and revision block; the graphic scale survives reproduction while a written ratio does not.

  • Spot elevations are shown to 0.01 ft at grade breaks, inlets, corners, and finished floor; contours alone are insufficient for construction.

  • Planting plan legend content: botanical name, common name, size (caliper, height, spread), root type, spacing, and quantity.

  • Section cut lines on the plan must match section-drawing labels such as A-A and B-B and must show the viewing direction.

  • Scale conventions: 1"=10' to 1"=20' for details, 1"=20' to 1"=40' for site plans, 1"=100' for planning exhibits.

  • Bubble diagrams communicate adjacency before scale; test-fit plans then verify dimensions against code and program requirements.