MA Elevator Mechanic cheat sheet
MA Elevator Mechanic · Keep the key ideas within reach.
Scope of Board of Elevator Regulations: Construction, Installation, Alteration, Operation
Massachusetts elevator law is administered under M.G.L. c. 143, §§ 62-71B, with the Board of Elevator Regulations issuing the administrative code (524 CMR) that governs construction, installation, alteration, and operation.
Covered equipment generally includes passenger and freight elevators, dumbwaiters, escalators, moving walks, wheelchair lifts, and other hoisting/lifting mechanisms; the code text defines the exact enumerated list and exclusions.
New installation, alteration, and major repair require a permit before work begins; routine maintenance does not, but maintenance must be performed by licensed personnel under the code.
An elevator inspector license is required to perform inspections and issue certificates; mechanics performing installation, alteration, maintenance, or repair must hold the appropriate mechanic license class.
A certificate of inspection is issued after a satisfactory inspection and must be posted in the elevator or machine space as the code directs; operation without a valid certificate is prohibited.
Periodic inspection intervals and the certificate term are set by the Board's regulations; the owner or lessee is responsible for arranging inspection before expiration.
The Board may suspend or revoke a license or certificate, or order equipment taken out of service, for code violations or unsafe conditions; an unsafe elevator must be shut down until corrected and reinspected.
Accident reporting: serious accidents and fatalities involving covered equipment must be reported to the state elevator authority within the time and in the manner the regulations specify.
Local building permits and zoning approvals do not substitute for elevator permits; state elevator approval is a separate, additional requirement.
Code Editions, Variances, and Administrative Rules
524 CMR incorporates by reference national consensus standards (ASME A17.1 for elevators/escalators, A17.3 for existing installations, A18.1 for platform lifts); the adopted edition governs, not the newest published edition.
A17.3 governs existing elevators not required to be upgraded to A17.1; alteration work triggers the newer standard only to the extent the code specifies.
Variances from code requirements must be requested from the Board in writing and are granted only on a showing of equivalent safety; a variance is equipment- and site-specific.
Plans and specifications for new installations and alterations are submitted to the state for review before a permit is issued; work may not start on unapproved plans.
The licensed contractor and licensed mechanic are jointly responsible for code compliance of installed work; the owner bears responsibility for operation and maintenance compliance.
Inspection fees, permit fees, and license fees are set by regulation; work performed without a required permit is subject to stop-work orders and penalties.
Records of inspections, tests, and maintenance must be retained and made available to the inspector on request.
Where the code and a referenced standard conflict, the regulation text controls; where the regulation is silent, the referenced standard applies.
Licensing, Permits, and Inspection Workflow
Workflow sequence: plans reviewed and permit issued → installation or alteration performed by licensed mechanic → acceptance test witnessed → certificate of inspection issued → periodic inspections thereafter.
Acceptance testing for new and altered equipment includes the safety tests specified in the referenced standard (e.g., governor and safety, buffer, door interlock, terminal stopping, emergency braking for escalators).
Periodic inspection categories (annual, biennial, etc.) depend on equipment type and use; the certificate lists the required interval and expiration date.
A mechanic license class limits the work an individual may perform; supervision requirements apply to apprentices and helpers working under a licensed mechanic.
Contractor (elevator company) licensing is separate from individual mechanic licensing; both are required for legal installation and alteration work.
When equipment is altered, the existing certificate is void until the alteration is inspected and a new certificate is issued.
Out-of-service tagging: equipment removed from service for safety must be tagged and secured, and may not be returned to service until repaired and inspected as required.
Insurance and continuing-education requirements attach to license renewal; lapsed licenses prohibit performing regulated work.
Operation, Maintenance, and Owner Duties
Owner duties: keep the elevator in safe operating condition, ensure required maintenance and testing, post the certificate, and arrange inspections before expiration.
Maintenance must be performed at the frequency needed to keep equipment in compliance; the code sets minimum maintenance and testing tasks for safety devices.
Safety devices requiring periodic testing include door interlocks and restrictors, emergency terminal stopping, governors and safeties, buffers, and standby power operation.
Machine rooms and spaces must be kept locked, free of storage, adequately lit, and accessible only to authorized personnel.
Passenger entrapment: the owner must provide means for emergency communication or alarm as the code requires, and a documented rescue procedure must exist.
Escalator and moving walk operation requires posted safety signage, functioning comb plates and skirt guards, and stopping devices at both landings.
Any change in use, capacity, speed, or travel that affects code compliance is an alteration requiring approval, not routine maintenance.
Firefighters' service and emergency operation features must be maintained and tested; deactivation without approval is a violation.
Enforcement, Violations, and Accident Reporting
An inspector may issue a violation notice and order corrections within a stated time; failure to correct can result in suspension of the certificate and an order to stop operation.
The Board may impose fines, suspend or revoke licenses, and seek injunctive relief for unlicensed work or continued noncompliance.
Unlicensed installation or alteration is grounds for a stop-work order and may require removal or rework of the noncompliant installation at the responsible party's expense.
Serious injury or fatality incidents must be reported promptly to the state authority; the equipment is typically secured pending investigation and may not be altered before inspection.
Appeal of a Board or inspector order follows the regulation's administrative process; operating during an appeal of a shutdown order is not permitted absent a stay.
Reinspection after correction is required before the certificate is restored; the reinspection fee may apply.
Records of accidents, repairs, and tests are subject to inspection by the authority and may be used in enforcement proceedings.
Municipal fire and building officials may also inspect for fire-safety features, but elevator code enforcement rests with the state elevator authority.