MA Plumber flashcards
MA Plumber · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Plumbing permit requirement
- A plumbing permit must be obtained from the local plumbing inspector before beginning installation, alteration, or replacement work; journeymen and apprentices cannot legally pull plumbing permits.
- Rough-in inspection
- The inspection of installed drainage, waste, vent, and water piping after it is complete and tested but before it is concealed by walls, floors, or ceilings.
- Final plumbing inspection
- The last inspection, occurring after all fixtures, appliances, and trim are installed and all required tests have passed, allowing the work to be approved and placed in service.
- State Plumbers and Gas Fitters Board
- Massachusetts board that licenses plumbers and gas fitters, adopts the Uniform State Plumbing Code (248 CMR 10.00), and hears appeals from decisions of local plumbing inspectors.
- Water supply fixture unit
- A value assigned to a fixture that expresses its probable demand on the water distribution system, used with code tables to size piping, branches, and meters.
- Minimum pressure, tank water closets
- A flowing pressure of at least 8 psi must remain at a tank-type water closet for proper refill; flushometer valves require roughly 15 psi.
- Flushometer valve minimum pressure
- Flushometer valves require a minimum flowing pressure of about 15 psi, and the branch serving a flushometer water closet must be at least 1 inch.
- Reduced pressure zone backflow preventer
- An assembly with two independently acting check valves and a differential relief valve, used where a cross-connection would create a health hazard to the potable supply.
- T&P relief valve
- A device on a water heater that opens at excessive temperature or pressure; its discharge pipe must end within 6 inches of the floor with an unthreaded end.
- Drainage fixture unit
- A value expressing the rate at which a fixture discharges into the drainage system, used with code tables to size fixture branches, stacks, and building drains.
- Slope of horizontal drainage pipe
- Horizontal drainage pipe of 2 1/2 inches and smaller must slope at 1/4 inch per foot; pipe 3 inches and larger may slope at 1/8 inch per foot.
- Trap seal depth
- The water seal in a plumbing trap must be at least 2 inches and not more than 4 inches deep to keep sewer gas from entering the building.
- Vent terminal above roof
- A vent stack terminates in open air at least 6 inches above the roof surface, higher where snow depth requires, and clear of windows, doors, and air intakes.
- Cleanout at base of stack
- A cleanout is required at the base of every vertical drainage stack, and horizontal building drains need cleanouts at intervals not exceeding 100 feet.
- Water closet flush volume limit
- Massachusetts limits new water closets to 1.28 gallons per flush, below the federal maximum of 1.6 gallons, reducing water use in new and replacement installations.
- Water closet sidewall clearance
- A water closet must be centered at least 15 inches from any side wall and have at least 30 inches of clear space across its front for use.
- Grease interceptor requirement
- Food service establishments must install a grease interceptor on drainage from fixtures that discharge fats, oils, and grease, with a flow-control fitting and venting.
- Indirect waste air gap
- An indirect waste must discharge through an air gap of at least twice the diameter of the receiving pipe, or at least 1 inch, to prevent backflow contamination.
- Gas piping pressure test
- Gas piping is pressure tested with air or inert gas at not less than 3 psi, or 1.5 times working pressure, and held at least 10 minutes without loss.
- Sediment trap at appliance
- A sediment trap or drip leg, full size of the appliance connector, is installed at the appliance to capture dirt and pipe scale before it reaches gas controls.
- Appliance shutoff valve location
- A manual shutoff valve must be installed ahead of each gas appliance, located in the same room and within easy reach for emergency shutdown.
- CSST bonding requirement
- Corrugated stainless steel tubing must be bonded to the building grounding electrode system to reduce the risk of damage from lightning-induced electrical arcing.
- Gas pipe through masonry wall
- Gas piping passing through masonry or concrete must be protected by a sleeve and may not run inside ducts, chimneys, elevator shafts, or concealed inaccessible spaces.
- Outdoor combustion air openings
- When outdoor combustion air is supplied through two horizontal ducts, each opening is sized at 1 square inch of free area per 2,000 Btu/hr of total appliance input.
- Type B vent clearance
- Listed Type B gas vent must maintain at least 1 inch of clearance to combustible materials and has a double wall that keeps flue gases warm.
- Vent connector slope
- A vent connector must slope upward toward the vertical vent at not less than 1/4 inch per foot of horizontal run so flue gases travel properly.
- Confined space combustion air
- A space with less than 50 cubic feet of volume per 1,000 Btu/hr of appliance input is confined and requires two permanent openings for combustion air.
- Category I appliance
- A gas appliance that operates with negative vent pressure and flue gas temperatures high enough to prevent condensation, typically vented by natural draft.
- Master plumber authority
- Only a licensed master plumber may obtain plumbing permits, contract plumbing work, and supervise journeymen and apprentices under the Massachusetts code.
- Trench protective system threshold
- OSHA requires a protective system such as sloping, shoring, or a trench box for excavations 5 feet deep or more where a cave-in hazard exists.
- Dig Safe notification
- Massachusetts requires excavators to notify Dig Safe at least 72 hours before digging so that underground utilities can be located and marked.
- GFCI on construction sites
- All 120-volt temporary receptacles on a construction site must have ground-fault circuit interrupter protection for personnel.