- Fixture unit
- A dimensionless measure of the probable load a fixture places on a drainage or water supply system; one drainage fixture unit equals about 1 cubic foot per minute, or 7.48 gpm.
- Authority having jurisdiction
- The organization or official responsible for enforcing the plumbing code, approving alternate materials and methods, issuing permits, and performing the required inspections.
- Code as minimum standard
- Plumbing codes set minimum requirements for health and safety, so a code-compliant installation is the floor rather than the ceiling, and stricter local amendments control.
- Residual pressure
- Residual pressure is the pressure remaining at a fixture or outlet while water is flowing; adequate residual pressure ensures fixtures function without being starved by undersized piping.
- Pressure-reducing valve
- A regulating device installed downstream of the meter when static supply pressure exceeds about 80 psi, protecting fixtures and piping from excess pressure and water hammer damage.
- Static versus flow pressure
- Static pressure is measured with no water moving; flow or residual pressure is measured while water moves. The difference reflects friction loss in the meter and piping.
- Water hammer arrestor
- A prefabricated device containing a trapped air or gas cushion, installed near quick-closing valves to absorb the pressure surge created when flow stops abruptly.
- Trap seal depth
- The trap seal is the water held in a fixture trap that blocks sewer gas; codes require a seal at least 2 inches and no more than 4 inches deep.
- Drainage slope for small pipe
- Horizontal drainage pipe 2 inches and smaller is typically installed at 1/4 inch per foot, while 3-inch through 6-inch pipe uses 1/8 inch per foot.
- Vent terminal height
- A vent stack must terminate outdoors, typically at least 6 inches above the roof surface and far enough from windows, doors, and air intakes to prevent odor entry.
- Cleanout location
- Cleanouts are required at the base of each stack, at the building drain, at intervals not exceeding 100 feet of horizontal run, and at turns greater than 45 degrees.
- Wet vent
- A wet vent is a drain serving one or more fixtures that also vents a downstream fixture, permitted only within the size and length limits set by code.
- Water closet flow rate
- Federal standards limit new tank-type water closets to 1.6 gallons per flush, and many jurisdictions and the WaterSense program require 1.28 gallons per flush or less.
- Showerhead flow limit
- Showerheads are limited to 2.5 gallons per minute at 80 psi test pressure; multi-head installations must also satisfy aggregate flow and local code requirements.
- Fixture trap requirement
- Every fixture that discharges sewage or liquid waste must be trapped, except fixtures with an integral trap, and each trap must be vented unless an approved exception applies.
- TP relief valve
- The temperature-and-pressure relief valve protects a water heater from over-pressure or overheating; its discharge pipe must remain full size, drain by gravity, and terminate safely.
- Water heater drain pan
- A drain pan is required where a water heater is installed in a location where leakage could cause damage; the pan must drain or be piped to a safe disposal point.
- Thermal expansion tank
- On a closed system with a backflow preventer or check valve, an expansion tank absorbs the volume increase as water heats, preventing relief valve discharge and pressure damage.
- Copper water tube types
- Copper water tube comes in types K, L, and M, with K the thickest wall, L intermediate, and M thinnest; type M is restricted in some concealed or underground uses.
- Dielectric union
- A dielectric union separates dissimilar metals such as copper and steel with a nonmetallic insulator, preventing galvanic corrosion at the threaded connection between them.
- PEX expansion fitting
- With PEX-A tubing, an expansion tool stretches the pipe, an expanded fitting is inserted, and the pipe shrinks back over the fitting to form a permanent seal without crimp rings.
- Solvent cement joint
- A solvent-cemented plastic joint requires cleaning, applying primer where required and cement to both surfaces, assembling with a quarter turn, and holding until the joint sets.
- Sediment trap
- A sediment trap, or drip leg, is a capped vertical extension at the appliance gas inlet that catches dirt and pipe scale before it can reach the gas valve.
- Unconfined space combustion air
- An indoor space is treated as unconfined when it provides roughly 50 cubic feet of volume per 1,000 Btu/hr of appliance input and is not of tight construction.
- CSST bonding
- Corrugated stainless steel tubing must be bonded to the grounding electrode system with a listed clamp and conductor, commonly 6 AWG copper, to reduce damage from lightning arcs.
- Air gap
- An air gap is the unobstructed vertical distance between a potable water outlet and the flood level rim of the receiving fixture, typically twice the pipe diameter and at least 1 inch.
- Reduced pressure zone assembly
- An RPZ is a testable backflow assembly for high-hazard connections, using two independent check valves and a differential relief valve that discharges if flow reverses.
- Atmospheric vacuum breaker
- An atmospheric vacuum breaker must be installed downstream of the last control valve, at least 6 inches above the highest downstream outlet, and cannot be under continuous pressure.
- Developed length
- Developed length is the total measured piping length from the source to the most remote outlet, including allowances for fittings, and is used to size water and gas piping.
- Riser diagram
- A riser diagram is a single-line isometric drawing showing the arrangement, sizes, and connections of water, drain, waste, and vent piping through the building floors.
- DWV hydrostatic test
- A DWV system is commonly tested by filling it with water to a 10-foot head for 15 minutes, or by an approved air test where permitted, with all joints leak-free.
- Potable line disinfection
- New or repaired potable water piping is disinfected, commonly with a chlorine solution of about 50 ppm for 24 hours, then flushed and sampled for satisfactory bacteriological results.