MD Elevator Mechanic cheat sheet
MD Elevator Mechanic · Keep the key ideas within reach.
Elevator and Escalator Code Compliance
ASME A17.1/CSA B44 is the model safety code adopted by reference in Maryland; ASME A17.3 governs existing (pre-code) installations.
ASME A17.2 is the inspection code: it defines the acceptance, periodic (Category 1 and Category 5), and witnessing test procedures a mechanic performs.
Category 1 periodic test: annually or as scheduled; Category 5: every 5 years and includes full-load brake, safety (governor-tripped), and buffer tests on traction elevators.
Governor trip speed must fall in the range 115%-140% of rated car speed for the safety device to be accepted.
Car and counterweight oil buffers: verify oil level and that the buffer returns fully within 90 seconds after compression; spring buffers require no oil.
Escalator acceptance requires brake stopping distance within the code table and no more than the specified handrail/step speed differential (handrail speed within -0/+2% of step speed).
Door closing force: kinetic energy limited to 3.5 ft-lbf (approx. 4.75 J) average and 7 ft-lbf peak, measured with the closed-door force gauge per A17.1.
Top-of-car clearance and pit depth must meet the code minimums for the rated speed; refuge space above the car and below the pit floor is mandatory.
Firefighters' Emergency Operation (Phase I/II) recall and in-car operation must be tested and documented at each periodic inspection.
Mechanical and Electrical Systems
Traction machine uses a grooved sheave and counterweight; roping factor 1:1 means car speed equals rope speed, 2:1 means car speed is half rope speed.
Counterweight = car weight + approximately 40-50% of rated load; balance determines motor sizing and brake duty.
Geared traction machines use worm gears; gearless (direct-drive) machines use a large sheave on the motor shaft for high-speed/high-rise duty.
Hydraulic (in-ground or holeless) systems use a power unit, jack, and plunger; relief valve setting must be 150%-200% of full-load pressure and no higher than the jack/cylinder rating.
Variable-voltage (Ward-Leonard) and ACVV/VVVF drives control acceleration; SCR and IGBT drives require proper grounding and harmonic mitigation.
Safety chain: governor, safety blocks, and rope equal to or greater than the suspension means; safety must stop and hold the car with rated load.
Escalator drive: motor, main brake, and a second (auxiliary) brake on the drive shaft required on newer units; step chain and skirt clearance are key wear points.
Electrical: three-phase motor rotation, correct fuse/breaker sizing per nameplate FLA, and a disconnecting means within sight of the controller are required.
Safety and Maintenance Procedures
Lockout/tagout: open the mainline disconnect, verify zero energy with a meter, and apply a personal lock before entering the pit or machine room.
Never work alone on top of a car; use the car-top operating station with inspection speed (typically 150 fpm max) and the stop switch within reach.
Pit entry: place the car at the top landing, use the pit stop switch, and keep the pit light on; never enter a pit with the car above without blocking.
Before jacking a hydraulic elevator, set the car on safeties or pipe stands; never rely on the power unit valve to hold the car.
Housekeeping: keep machine room and pit free of stored combustibles; code requires machine room temperature control and no sprinkler heads without shunt trip.
Maintenance records: log oil levels, brake wear, governor seal, rope condition (broken wire count per lay), and door operator adjustments at each visit.
Escalator comb and skirt inspection: check for missing teeth, step-to-skirt clearance, and handrail speed; remove debris from the comb pan.
Emergency: use the manual lowering valve for hydraulic entrapment and the manual brake release for traction; communicate with passengers before moving the car.
Maryland Licensing Laws and Regulations
Elevator mechanics and contractors are licensed by the Maryland Department of Labor, Division of Occupational and Professional Licensing (Elevator Safety).
A licensed elevator mechanic may perform installation, alteration, maintenance, and repair; an apprentice must work under direct supervision of a licensed mechanic.
Continuing education is required for license renewal; the Division sets the credit hours and code-update content per renewal cycle.
Permits: a permit from the local jurisdiction (or the State for State-owned/State-regulated conveyances) is required before installing or altering an elevator or escalator.
Inspections: the licensed third-party inspector performs periodic inspections; the mechanic's company must correct violations and request reinspection within the time ordered.
License display and identification: the license number must be available on request; unlicensed practice is subject to civil penalties and license denial or revocation.
Reciprocity: Maryland may accept out-of-state credentials only where the Division has an approved agreement; verify before advertising services.
Reportable incidents: accidents causing injury or entrapment must be reported to the Division within the timeframe set by regulation; the conveyance may be locked out pending investigation.