  • Water column: 1 psi = 2.31 ft of water head; conversely 1 ft of head = 0.433 psi. Use to convert static pressure to elevation and back.

  • Fixture unit basis: 1 water supply fixture unit (wsfu) = 1 gpm demand, roughly matched to a 3/4-inch flushometer or 1.6 gpf tank-type water closet under the standard Hunter method.

  • Slope: 1/4 inch per foot = 2 percent; 1/8 inch per foot = 1 percent; 1/16 inch per foot = 0.5 percent. Slope in percent = (rise / run) x 100.

  • Drainage fixture units (DFU) convert fixture counts to pipe size; a 1.6 gpf water closet is 3 DFU, a floor drain 2 DFU, a lavatory 1 DFU.

  • Developed length includes fittings; fitting allowance is added as equivalent length (e.g., 90-degree elbow ~ 2-3 pipe diameters of straight pipe, depending on table used).

  • Thermal expansion of water is about 4 percent by volume from 40 F to 140 F; closed systems need an expansion tank or relief provision.

  • Pressure test for DWV: water test 10 ft head minimum (about 4.3 psi) for 15 minutes, or air test at 5 psi for 15 minutes depending on the adopted code.

  • Flow velocity: keep domestic cold water below 8 fps and hot water below 5 fps to limit erosion and noise; 4-8 fps is the common design band.

Quick reference

Plumbing Fixtures and Equipment

  • Water closet limits (federal/EPAct baseline): 1.6 gallons per flush; urinal 1.0 gpf; showerhead 2.5 gpm at 80 psi; kitchen faucet 2.2 gpm; lavatory faucet 2.2 gpm (1.5 gpm for public lavatories in many codes).

  • Water heater temperature and safety: storage tank setpoint typically 120-140 F; scald protection required above 120 F at the fixture for bathing; T&P relief valve set at 150 psi or 210 F, whichever first.

  • T&P relief discharge must terminate by gravity, full size, within 6 inches of the floor or to a safe receptor, with no thread or cap on the end.

  • Fixture trap seal: 2 to 4 inches of water seal; trap arm length limited to the developed length permitted by the code (commonly 2 times the trap arm diameter in the drainage table).

  • Air gap is the only backflow protection that is not a device; minimum air gap is twice the effective opening of the supply pipe, never less than 1 inch.

  • Floor drains: trap primer or trap seal protection required where the trap is subject to evaporation; trap seal depth 2 to 4 inches.

  • Water closet rough-in: 12-inch rough-in places the drain centerline 12 inches from the finished wall; 10-inch and 14-inch rough-ins are the common alternates.

  • Backflow prevention: RPZ for high hazard, double check for low hazard, atmospheric vacuum breaker for hose bibbs and non-continuous use only.

Quick reference

Water Supply and Drainage Systems

  • Building drain vs building sewer: the building drain ends at the building wall (or 2 ft outside), and the building sewer begins there and runs to the public sewer or private disposal.

  • Vent stack and stack vent: a stack vent is the extension of a soil or waste stack above the highest fixture; a vent stack is a separate vertical vent for the drainage stack.

  • Wet vent rules: a wet vent may serve a bathroom group on the same floor when sized per table and the water closet is downstream of the vent connection, subject to local amendment.

  • Air admittance valves (AAVs) require at least one vent through the roof in the system and must be accessible; they do not replace a required vent terminal.

  • Water service sizing: use the fixture-unit method with the longest developed length and available pressure; subtract elevation (0.433 psi/ft) and meter/fixture losses.

  • Storm drainage: roof area (sq ft) x rainfall intensity (in/hr) / 96 = gpm; leader and horizontal storm drain size from that flow.

  • Backwater valve required on fixtures below the elevation of the next upstream manhole cover, where the code so requires.

  • Drainage grade: horizontal building drains 1/4 in/ft for 3-inch and smaller, 1/8 in/ft for 4-inch and larger, where the adopted code permits.

Quick reference

Maryland Plumbing Code and Regulations

  • Maryland adopts the International Plumbing Code (IPC) as the Maryland Plumbing Code through COMAR 09.12.22 (Plumbing Code), with state amendments; local jurisdictions may adopt stricter amendments.

  • Licensing: the Maryland State Board of Plumbing administers master and journeyman plumber licenses under the Department of Labor; a master license is required to obtain a plumbing permit and to contract for plumbing work.

  • Apprenticeship: supervised apprentice hours (commonly 4 years / 7,500-8,000 hours) plus passing the journeyman exam are prerequisites for the journeyman license; the master exam follows journeyman experience.

  • Permits and inspections: a plumbing permit is required before installation; rough-in and final inspections are mandatory, and work must not be concealed before rough-in approval.

  • Continuing education: Maryland requires continuing education units for license renewal (commonly 10 hours per 2-year cycle for master/journeyman), with code-update hours specified by the Board.

  • Home improvement: plumbing contractors must hold an MHIC license in addition to the master plumber license when contracting with homeowners for home improvement work.

  • Sewage and water: on-site sewage disposal is regulated by the Maryland Department of the Environment (MDE) and the local health department; a percolation test and permit are required before installation.

  • Cross-connection control: Maryland requires backflow prevention and annual testing of testable assemblies by a certified backflow tester, with reports filed to the local water authority.