ME Water Operator flashcards
ME Water Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CT value
- Product of disinfectant residual concentration in mg/L and effective contact time in minutes. Regulatory tables convert CT into log inactivation credit based on temperature, pH, and disinfectant.
- Breakpoint chlorination
- The chlorine dose at which free chlorine residual begins to rise after destroying ammonia and chloramines. Requires roughly 7.6 mg Cl2 per mg of ammonia nitrogen.
- Jar test
- Bench-scale simulation of coagulation, flocculation, and settling used to select chemical dose and pH. Rapid mix, slow flocculation, settle, then measure turbidity.
- Turbidity limit
- Conventional filtration must produce 0.3 NTU or less in 95% of monthly samples and never exceed 1 NTU. Slow sand and DE filters use a 1 NTU limit.
- Chlorine demand
- Difference between the chlorine dose applied and the residual remaining after a specified contact time. It reflects oxidizable matter and ammonia in the water.
- Filter backwash expansion
- Backwash rate must fluidize the bed enough to release captured solids, typically 20–25% bed expansion for anthracite and sand dual media.
- TTHM MCL
- Maximum contaminant level for total trihalomethanes is 0.080 mg/L, evaluated as a locational running annual average at each monitoring site.
- Enhanced coagulation
- Treatment technique that increases coagulant dose or lowers pH to remove natural organic matter, reducing disinfection byproduct precursors before chlorine is applied.
- Minimum distribution pressure
- Distribution systems must maintain at least 20 psi at all points under normal and emergency conditions, including main breaks and fire flow events.
- Hazen-Williams equation
- Empirical head loss formula: h = 10.44 × L × Q^1.85 / (C^1.85 × d^4.87) in US customary units, where C is the pipe roughness coefficient.
- Water hammer
- Pressure surge caused by rapid velocity change when a valve closes or a pump stops. Surge pressure rise is approximately 0.07 psi per ft/s of velocity change.
- Air gap
- Physical separation between a potable water outlet and the flood level of a receiving vessel. It is the only backflow prevention method that is completely reliable.
- RPZ assembly
- Reduced-pressure zone backflow preventer required for high-hazard cross connections. It uses two check valves and a relief valve that discharges if differential pressure is lost.
- Distribution flushing velocity
- Scouring velocity of at least 2.5 to 3.0 ft/s is needed to lift and carry sediment out of mains during unidirectional flushing programs.
- Main repair disinfection
- After repair, apply 50–100 mg/L chlorine for at least 30 minutes, flush the main, then collect coliform and chlorine residual samples before restoring service.
- Storage components
- Distribution storage is sized for equalization, fire flow, and emergency reserve. These are separate design components and are not interchangeable in sizing calculations.
- Total coliform 5% rule
- Systems collecting 40 or more routine samples per month may have no more than 5% total-coliform-positive samples. Any E. coli positive is an acute violation.
- Ground Water Rule
- Requires 4-log virus inactivation or removal for groundwater systems with a significant deficiency or fecal indicator contamination, or a state-approved alternative.
- Consumer Confidence Report
- Annual report of detected contaminants and monitoring results delivered to customers by July 1, covering the previous calendar year of sampling.
- Lead action level
- Lead action level is 0.015 mg/L at the 90th percentile. Exceedance triggers corrosion control evaluation, source water treatment, and public education.
- Copper action level
- Copper action level is 1.3 mg/L at the 90th percentile. Exceedance requires corrosion control treatment evaluation and public education within set deadlines.
- Arsenic MCL
- Maximum contaminant level for arsenic is 0.010 mg/L. Treatment options include coagulation with iron, ion exchange, and adsorption media.
- Nitrate MCL
- Maximum contaminant level for nitrate is 10 mg/L as nitrogen, equivalent to 45 mg/L as nitrate. It protects against methemoglobinemia in infants.
- Public notification tiers
- Tier 1 acute violations require notice within 24 hours, Tier 2 within 30 days, and Tier 3 within one year through the Consumer Confidence Report.
- Wellhead protection area
- Land surface around a well through which contaminants could reach the well. Delineation supports source water inventory and contaminant management.
- Confined space atmosphere
- Entry requires oxygen between 19.5 and 23.5%, LEL below 10%, hydrogen sulfide below 10 ppm, and carbon monoxide below 35 ppm before and during entry.
- Chlorine gas behavior
- Chlorine gas is about 2.5 times heavier than air and collects in low areas. Escape or entry requires SCBA, not an air-purifying respirator.
- Lockout tagout
- Energy isolation procedure under 29 CFR 1910.147. Only the worker who applied the lock and tag may remove them after verifying zero energy.
- Hypochlorite storage
- Sodium hypochlorite degrades faster in heat and releases oxygen gas. Store in vented, shaded tanks away from acids to prevent chlorine gas release.
- Boil-water notice
- Public advisory to boil water for at least one minute before drinking. Rescinded only after two consecutive negative coliform samples and agency approval.
- GFCI protection
- Ground-fault circuit interrupter protection is required for portable electrical tools used in wet or damp areas such as treatment basins and pump rooms.
- Emergency response plan
- Documented procedures for contamination, pressure loss, power failure, and main breaks. It should be exercised with tabletop drills at least annually.