Michigan Low Voltage Practice key terms
Michigan Low Voltage Practice · Get comfortable with the vocabulary.
- Low Voltage
- Related: Class 2 Circuit, Class 3 Circuit, Remote-Control Circuit
In Michigan practice, circuits operating at 50 volts or less, such as communications, signaling, and control wiring, which fall under Article 725 and related articles rather than power wiring rules.
- Class 1 Circuit
- Related: Class 2 Circuit, Class 3 Circuit
A circuit whose power source and wiring are not limited to Class 2 or 3 energy levels, so it must follow the stricter wiring methods of Part II of Article 725.
- Class 2 Circuit
- Related: Class 3 Circuit, Power-Limited Circuit, Class 2 Power Source
A circuit supplied by a listed Class 2 power source that limits energy to levels considered safe for fire and shock, allowing lighter wiring methods and fewer physical protections.
- Class 3 Circuit
- Related: Class 2 Circuit, Class 2 Power Source
A circuit supplied by a listed Class 3 power source, with energy limits above Class 2 but still below Class 1, permitting reduced wiring methods while requiring more protection than Class 2.
- Class 2 Power Source
- Related: Class 2 Circuit, Class 3 Circuit
A listed transformer, power supply, or battery arrangement whose output is tested and marked to stay within Class 2 voltage and current limits under any load condition.
- Remote-Control Circuit
- Related: Class 1 Circuit, Signaling Circuit
A circuit that carries signals to operate equipment such as motors, contactors, or valves from a distance, governed by Article 725 when it operates at limited energy.
- Signaling Circuit
- Related: Fire Alarm Circuit, Notification Appliance Circuit
A circuit that activates an indicator, alarm, or annunciator in response to a condition, including fire alarm and security signaling covered by Article 760.
- Fire Alarm Circuit
- Related: Initiating Device Circuit, Notification Appliance Circuit, Signaling Circuit
Wiring that connects initiating devices, control equipment, and notification appliances in a fire detection or alarm system, installed under Article 760 requirements.
- Initiating Device Circuit
- Related: Fire Alarm Circuit, Notification Appliance Circuit
The path connecting automatic detectors and manual pull stations back to the fire alarm control unit so the panel can register an alarm or supervisory condition.
- Notification Appliance Circuit
- Related: Fire Alarm Circuit, Signaling Circuit
The wiring that supplies horns, strobes, speakers, and similar devices so occupants are warned when the fire alarm system operates.
- Communication Circuit
- Related: Class 2 Circuit, Cable Tray
Premises wiring for telephone, data, and similar signals, covered by Article 800, which permits cable types and installation methods suited to low-energy communications.
- Plenum
- Related: Riser, NM Cable, Raceway
A space used for air handling, such as above a suspended ceiling that serves as a return-air path, where cable jackets must meet low smoke and flame-spread requirements.
- Riser
- Related: Plenum, Raceway
A vertical shaft or run between floors that carries cabling, requiring cable listings rated for vertical flame propagation when installed in that space.
- Raceway
- Related: Conduit Fill, Plenum
An enclosed channel such as conduit, tubing, or wireway designed to hold and protect conductors and cables along a defined route.
- Conduit Fill
- Related: Raceway, Support and Securing
The percentage of a raceway's cross-sectional area occupied by conductors, kept within code limits so cables can be pulled without damage and heat can dissipate.
- Support and Securing
- Related: Raceway, Box Fill
The required fastening of cable and raceway at intervals and within specified distances of boxes, so wiring stays in place and strain is not transferred to terminations.
- Box Fill
- Related: Support and Securing, Junction Box
The calculation that limits how many conductors, devices, and fittings may occupy a box, based on conductor size and the volume marked on the enclosure.
- Junction Box
- Related: Box Fill, Raceway
An enclosure where conductors are spliced or where circuits branch, required to be accessible and sized so splices and devices fit without crowding.
- NM Cable
- Related: Raceway, Plenum
A factory assembly of insulated conductors with an overall nonmetallic sheath, commonly called Romex, permitted only in specific locations under Michigan's adopted code.
- Grounding
- Related: Bonding, Equipment Grounding Conductor, Grounding Electrode
Connecting electrical equipment and systems to the earth so fault current has a defined path and voltage on exposed metal parts is limited.
- Bonding
- Related: Grounding, Equipment Grounding Conductor, Bonding Jumper
Joining metal parts together electrically so they remain at the same potential, preventing dangerous voltage differences between enclosures, raceways, and piping.
- Equipment Grounding Conductor
- Related: Grounding, Bonding, Grounding Electrode
The conductor that connects the metal frames and enclosures of equipment to the grounding system, providing a low-impedance path for fault current.
- Grounding Electrode
- Related: Grounding Electrode Conductor, Grounding
A conductive object in direct contact with the earth, such as a ground rod or metal water pipe, that ties the grounding system to earth.
- Grounding Electrode Conductor
- Related: Grounding Electrode, Grounding
The conductor that links the grounding electrode to the service or system grounded conductor and equipment grounding conductors at the service point.
- Bonding Jumper
- Related: Bonding, Equipment Grounding Conductor
A conductor sized to carry fault current that ensures metal parts, such as a raceway and a box, are electrically joined so no voltage difference develops.
- Ground-Fault Circuit Interrupter
- Related: Grounding, Arc-Fault Circuit Interrupter
A device that trips when current leaks from the intended circuit path to ground, protecting people from shock in wet or otherwise hazardous locations.
- Arc-Fault Circuit Interrupter
- Related: Ground-Fault Circuit Interrupter
A device that detects the signature of arcing in wiring and opens the circuit, reducing the chance that a damaged conductor starts a fire.
- Working Clearance
- Related: Lockout/Tagout
The clear space required in front of electrical equipment so a person can safely work on it without contacting live parts or obstructions.
- Lockout/Tagout
- Related: Working Clearance, Grounding
A procedure that de-energizes equipment and applies locks and tags so power cannot be restored while someone is servicing the circuit.
- Permit
- Related: Plan Review, Rough-In Inspection, Final Inspection
Written authorization from the local enforcing agency allowing regulated electrical work to begin, based on an application describing the scope and location.
- Plan Review
- Related: Permit, Rough-In Inspection
The agency's examination of submitted drawings and specifications before construction, confirming the proposed work will meet code before installation starts.
- Rough-In Inspection
- Related: Final Inspection, Permit
The inspection performed after framing and wiring are installed but before concealment, when boxes, cables, and grounding can still be examined and corrected.
- Final Inspection
- Related: Rough-In Inspection, Certificate of Occupancy
The last inspection, done after devices, fixtures, and finishes are complete, confirming the finished installation is safe and matches the permitted scope.
- Certificate of Occupancy
- Related: Final Inspection, Permit
A document issued by the building authority confirming a structure may be used for its intended purpose, typically after electrical final approval.
- Electrical Contractor License
- Related: Journeyman Electrician, Master Electrician, Apprentice
A Michigan credential authorizing a business to contract for electrical work, held by the qualifying master or journeyman who supervises the work.
- Journeyman Electrician
- Related: Master Electrician, Electrical Contractor License, Apprentice
A Michigan licensee who has completed required experience and examination and may perform electrical work under a master's or contractor's supervision.
- Master Electrician
- Related: Journeyman Electrician, Electrical Contractor License
A Michigan licensee qualified by experience and examination to supervise electrical work and to serve as the qualifying person for a contracting business.
- Apprentice
- Related: Journeyman Electrician, Master Electrician
A person registered in a supervised training program who may perform electrical work only under the direct oversight of a licensed electrician.