Quick reference

Water Treatment Processes

  • Rapid mix disperses coagulant in roughly 10–30 seconds at high intensity (velocity gradient G ≈ 300–1000 s⁻¹); flocculation follows for 15–45 minutes at gentle G ≈ 10–75 s⁻¹.

  • Sedimentation surface overflow rate = flow ÷ basin surface area; particles with a settling velocity equal to or greater than the overflow rate are removed.

  • Conventional filter loading is typically 2–6 gpm/ft²; backwash is typically 15–20 gpm/ft², producing about 20–30% bed expansion.

  • Dual-media beds use anthracite (≈0.9–1.1 mm effective size) over sand (≈0.45–0.55 mm), giving coarse-to-fine grading that stores solids through the bed depth.

  • A jar test identifies the coagulant dose and pH that meet the turbidity goal at the lowest chemical dose; it simulates rapid mix, flocculation, and settling.

  • Lime-soda softening precipitates calcium carbonate and magnesium hydroxide; excess lime raises pH above about 10.5, so recarbonation is used to stabilize the water.

  • Iron and manganese are removed by oxidation (aeration, chlorine, or permanganate) followed by filtration; manganese greensand and catalytic media are common.

  • Filtered surface water must be ≤0.3 NTU in at least 95% of monthly samples and must never exceed 1 NTU.

Quick reference

Water Distribution Systems

  • A minimum pressure of 20 psi should be maintained at all points in the distribution system, including during fire flow, to prevent backflow and contamination.

  • A detectable disinfectant residual must persist throughout the system; a free chlorine residual of about 0.2 mg/L or greater is a common distribution minimum.

  • Design velocities are generally 2–5 ft/s: below 2 ft/s settling and stagnation occur, while above 5 ft/s head loss and pipe erosion increase sharply.

  • Hazen-Williams head loss varies with flow raised to about 1.85 and with pipe diameter raised to about 4.87, so small diameter changes greatly affect friction loss.

  • Unidirectional flushing at 2.5 ft/s or more scours sediment and biofilm; valves are sequenced so flow travels in one direction.

  • An air gap is the most reliable backflow protection; reduced-pressure-zone assemblies are used for high-hazard connections where an air gap is impractical.

  • A main break that drops pressure below 20 psi triggers a precautionary boil water notice until repairs and bacteriological sampling clear the system.

  • Storage tanks require turnover and inspection; stagnant water loses residual, stratifies, and can develop biofilm and nitrification.

Quick reference

Pumps, Motors, and Hydraulics

  • Head in feet of water = psi × 2.31; pressure in psi = feet of head × 0.433 × specific gravity.

  • Water horsepower = (gpm × total head in ft × specific gravity) ÷ 3960.

  • Brake horsepower = water horsepower ÷ pump efficiency; motor input horsepower = brake horsepower ÷ motor efficiency.

  • Affinity laws for a centrifugal pump: flow varies directly with speed, head with speed squared, and power with speed cubed.

  • Pumps in series pass the same flow and add heads; pumps in parallel operate at the same head and add flows.

  • Cavitation occurs when NPSH available is less than NPSH required; vapor pressure rises with water temperature, reducing available NPSH.

  • Three-phase electrical power in kW = (volts × amps × power factor × 1.732) ÷ 1000.

  • For a centrifugal pump, power draw generally increases as flow increases; operating far right or left of the best efficiency point reduces efficiency and stresses the pump.

Quick reference

Water Quality, Disinfection, and Sampling

  • Hypochlorous acid (HOCl) is a much stronger disinfectant than hypochlorite ion (OCl⁻); the two are roughly equal near pH 7.5, and lower pH favors HOCl.

  • Combined chlorine = total chlorine − free chlorine; combined chlorine consists mainly of chloramines, which are weaker disinfectants that cause taste and odor.

  • Chlorine demand = applied dose − residual remaining after the required contact time.

  • CT = disinfectant residual (mg/L) × contact time (min); required CT increases as water temperature decreases, pH increases, and pathogen resistance increases.

  • Breakpoint chlorination requires roughly 7.6 mg of chlorine per mg of ammonia nitrogen to oxidize ammonia; free chlorine persists beyond the breakpoint.

  • Bacteriological samples are collected in 100 mL sterile, thiosulfate-treated bottles, held near 4°C, and analyzed within 30 hours of collection.

  • Conventional filtration must produce turbidity ≤0.3 NTU in at least 95% of monthly samples and never exceed 1 NTU; membrane systems target ≤0.1 NTU.

  • Heterotrophic plate count is limited to 500 CFU/mL; any total coliform-positive routine sample requires repeat sampling and E. coli confirmation.

Quick reference

Safety, Regulations, and Recordkeeping

  • Confined space entry requires oxygen between 19.5% and 23.5%, flammable gas below 10% of the lower explosive limit, and hydrogen sulfide below 10 ppm.

  • Lockout/tagout requires isolating the energy source, applying locks and tags, and then attempting to start the equipment to verify a zero-energy state.

  • A dilute ammonia solution held near a suspected leak forms a white cloud on contact with chlorine gas; responders wear SCBA and approach from upwind.

  • In Minnesota, the Minnesota Department of Health regulates public water systems and certifies water operators; systems submit routine compliance monitoring data to the state.

  • Primary MCLs include nitrate 10 mg/L as N, arsenic 10 µg/L, lead action level 0.015 mg/L, copper action level 1.3 mg/L, TTHM 80 µg/L, and HAA5 60 µg/L.

  • Tier 1 public notices are issued within 24 hours for immediate health risks; Tier 2 within 30 days; Tier 3 is included in the annual Consumer Confidence Report.

  • Community water systems must deliver the Consumer Confidence Report to customers by July 1 each year, covering source water, detected contaminants, and health effects.

  • Sanitary surveys of public water systems are conducted roughly every 3–5 years, depending on system type and compliance history.