MS Water Operator flashcards
MS Water Operator · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CT value
- Product of disinfectant residual concentration (mg/L) and contact time (minutes) used to determine disinfection credit; required CT increases with higher pH, lower temperature, and higher turbidity.
- Jar test purpose
- Bench-scale test that determines optimal coagulant dose and pH by simulating coagulation, flocculation, and settling; results guide full-scale chemical feed adjustments.
- Combined filter effluent turbidity
- For conventional filtration, must be 0.3 NTU or less in at least 95 percent of monthly measurements and never exceed 1 NTU; individual filter action level is 1.0 NTU.
- Alkalinity consumption by alum
- Each mg/L of alum dosed consumes about 0.45 mg/L of alkalinity; insufficient alkalinity drops pH and reduces coagulation effectiveness, requiring lime or caustic addition.
- DPD method
- Colorimetric test for free and total chlorine residual; reagent reacts with chlorine to produce a pink color measured against a standard, with total chlorine measured after adding iodide.
- Filter backwash triggers
- Backwash is initiated by headloss limit, turbidity breakthrough, or maximum run time; backwash rate should expand the media bed roughly 20 to 30 percent.
- Fluoride MCL and secondary standard
- Primary MCL for fluoride is 4.0 mg/L; secondary standard is 2.0 mg/L; optimal concentration is temperature-dependent, roughly 0.7 to 1.2 mg/L.
- Minimum distribution pressure
- Pressure must not fall below 20 psi at any point in the distribution system under normal or emergency conditions, including main breaks and fire flow.
- Hydrant flow formula
- Q equals 29.83 times C times d squared times the square root of pitot pressure, where d is nozzle diameter in inches and C is the discharge coefficient.
- New main disinfection
- Chlorinate new mains to 25 mg/L for 24 hours or 50 mg/L for 24 hours, flush, then obtain two consecutive negative bacteriological samples 24 hours apart.
- Air gap backflow protection
- Physical separation between the potable water outlet and the flood-level rim of the receiving vessel; provides the highest degree of backflow protection against backpressure and backsiphonage.
- Dead-end flushing velocity
- Flushing should achieve velocities above about 2.5 feet per second to scour biofilm and sediment from dead-end mains; frequency is set by residual and bacteriological history.
- Storage tank turnover
- Tank volume divided by average daily demand gives detention time; excessive detention degrades chlorine residual and increases disinfection byproduct formation.
- Pressure test for new mains
- Test at 1.5 times working pressure or 150 psi, whichever is greater, held at least 2 hours; allowable leakage follows the AWWA formula based on pipe length and diameter.
- Reduced-pressure zone assembly
- Backflow preventer with two check valves and a relief valve that protects against both backpressure and backsiphonage; requires annual testing by a certified tester.
- GWUDI determination
- Groundwater under the direct influence of surface water is determined by site-specific hydrogeologic and microbial investigation; such sources must meet surface water treatment rules.
- Well specific capacity
- Pumping rate divided by drawdown, expressed in gallons per minute per foot; declining specific capacity indicates clogging of the well screen or aquifer.
- Darcy's law
- Groundwater flow equals hydraulic conductivity times hydraulic gradient times cross-sectional area; describes flow through porous media under laminar conditions.
- Drawdown definition
- Difference between the static water level measured before pumping and the pumping water level measured during pumping; used to calculate specific capacity and well yield.
- Confined versus unconfined aquifer
- Confined aquifers are bounded by low-permeability layers and hold water under pressure; unconfined aquifers have a water table open to the atmosphere.
- Wellhead protection area
- Land surface around a well where contaminants could reach the well; delineated by time-of-travel zones, commonly one-year and five-year zones.
- Source water assessment
- Inventory of potential contaminant sources, susceptibility analysis, and public availability of results; states use it to support source water protection planning.
- Total coliform repeat sampling
- Each routine total coliform-positive sample requires repeat samples within 24 hours; a single positive routine sample triggers three repeat samples at that site.
- E. coli public notice
- An E. coli-positive repeat sample requires Tier 1 public notice within 24 hours; the system must also complete additional repeat sampling and corrective actions.
- TTHM and HAA5 MCLs
- Stage 2 DBPR locational running annual average MCLs are 80 micrograms per liter for total trihalomethanes and 60 micrograms per liter for five haloacetic acids.
- Lead and copper action levels
- Action level is 0.015 mg/L for lead and 1.3 mg/L for copper at the 90th percentile; exceedance triggers corrosion control treatment and public education.
- Consumer Confidence Report deadline
- Annual report must be delivered to customers by July 1 covering the prior calendar year, including source water, detected contaminants, and required health effects language.
- Public notice tiers
- Tier 1 notices within 24 hours for acute health risk; Tier 2 within 30 days; Tier 3 within one year, which the annual Consumer Confidence Report can satisfy.
- Confined space atmospheric limits
- Entry requires oxygen between 19.5 and 23.5 percent, combustible gas below 10 percent LEL, hydrogen sulfide below 10 ppm, and carbon monoxide below 35 ppm.
- Lockout tagout steps
- Isolate all energy sources, apply locks and tags by each worker, release stored energy, and verify zero energy before beginning work; only the applying worker removes the lock.
- Trench protection threshold
- Excavations 5 feet deep or greater require sloping, shoring, or a trench box; spoil piles at least 2 feet from the edge and ladders within 25 feet of workers.
- Tier 1 public notice deadline
- Notice within 24 hours for acute health risks such as E. coli or nitrate exceedance; must use methods that reach all customers and be documented.
- Risk-based asset prioritization
- Priority equals probability of failure times consequence of failure; used to sequence repair, rehabilitation, and replacement of distribution and treatment assets.