MT Journeyman Electrician study plan
MT Journeyman Electrician · Give each week a clear focus.
8 weeks · About 7 hours per week
Wiring Methods and Materials & Boxes, Raceways, and Conductor Fill
Build a one-page cross-reference table of NEC Chapter 3 Article numbers to their wiring method (NM, MC, AC, EMT, PVC, RMC, IMC, LFMC) and the permitted/not-permitted locations for each
Work through 25 practice problems on conductor ampacity and adjustment, applying the 310.16 table, ambient temperature correction, and 310.15(C)(1) bundling factors, showing every step
Solve 15 box-fill problems covering 314.16 volume allowances for conductors, devices, clamps, and supports, including multi-gang and box-with-plaster-ring cases
Calculate 12 raceway-fill scenarios for Chapter 9 Table 1 (40 percent for 3+ conductors) and Table 4, plus 8 conduit-bending radius and support-spacing questions from 344/358
Write a 10-line cheat card listing the ampacity of common copper THHN sizes from 14 AWG through 4/0 at 60, 75, and 90 degrees C
Your checkpoint
A completed 6-page reference packet (Article-to-method table, ampacity worksheet with 25 worked problems, 15 box-fill solutions, 20 raceway-fill/bending solutions, ampacity cheat card), self-scored at 80 percent or better
Wiring Methods and Materials & Boxes, Raceways, and Conductor Fill
Classify 40 installation scenarios by wiring method and location (dry, damp, wet, corrosive, exposed, concealed) and justify the permitted method with the specific NEC section
Compute 20 conductor-fill and 10 raceway-fill answers using Annex C where applicable, then verify each against Chapter 9 calculations
Derive pull-box and junction-box sizing from 314.28 for straight pulls, angle pulls, and U pulls, working 10 problems with raceway trade sizes from 3/4 inch to 4 inch
Identify 15 support and securing requirements (intervals, within 12 inches of boxes, exceptions for flexible connections) for EMT, PVC, MC, and NM
List the ten most common rough-in inspection failures in Chapter 3 work and the code section each violates
Your checkpoint
A 40-scenario wiring-method decision log with cited sections plus a 20-question self-quiz on boxes and raceways scored at 85 percent or better
Grounding, Bonding, and Overcurrent Protection & Branch Circuits, Feeders, and Service Calculations
Diagram the service grounding and bonding system from utility transformer through service point, grounding electrode conductor, grounding electrode system, main bonding jumper, equipment grounding conductors, and load-side bonding
Size grounding electrode conductors and equipment grounding conductors for 20 given service and feeder configurations using 250.66 and 250.122, including the upsizing rule when conductors are increased for voltage drop
Perform 15 standard service calculations using Article 220 optional and standard methods, including general lighting, small appliance, laundry, range, dryer, water heater, and HVAC loads
Calculate 10 feeder and 10 branch-circuit loads with continuous-load 125 percent factors and the 210.20 and 215.3 rules
Explain the difference between the grounded conductor, grounding electrode conductor, and bonding jumper in writing, with the code section that governs each
Your checkpoint
A one-page grounding and bonding schematic plus a 15-problem service-calculation worksheet with all work shown and answers verified
Branch Circuits, Feeders, and Service Calculations & General Electrical Knowledge and Theory
Solve 20 branch-circuit problems covering 210.52 receptacle spacing, 210.8 GFCI locations, 210.12 AFCI requirements, and 210.23 permissible loads
Compute 12 multi-family and 8 single-family dwelling load calculations from start to finish, including demand factors from Table 220.42 and 220.84 where applicable
Apply Ohm's law, series-parallel resistance, and power relationships to 25 circuit problems including balanced three-phase loads and power factor correction
Calculate voltage drop for 10 feeders using the circular-mils formula and verify compliance with 210.19(A) informational limits and 215.2(A)(1)
Work 10 problems on transformer basics, including turns ratio, primary and secondary current, and 450.3 overcurrent protection
Your checkpoint
A timed 50-question practice test covering Domains 1 and 4, completed in 75 minutes, with a written review of every missed item citing the governing section
Motors, Controls, and HVAC Equipment
Size branch-circuit conductors, overload protection, and short-circuit and ground-fault protection for 15 motor circuits using Tables 430.248 through 430.250 and 430.52
Determine disconnecting means, controller ratings, and overload sizing per 430.102, 430.83, and 430.32 for 10 motor installations
Calculate feeder ampacity for 8 multi-motor installations applying 430.24 and the largest-motor 125 percent adder
Trace a 10-step control circuit for a magnetic starter with start-stop pushbuttons, holding contact, and overload relay, and identify the terminal each conductor lands on
Answer 12 HVAC questions on 440 nameplate rated-load current, minimum circuit ampacity, maximum overcurrent protection, and the 440.6 versus 430 rules distinction
Your checkpoint
A motor-calculation portfolio of 15 fully worked motor circuits plus 8 multi-motor feeders and a labeled control-ladder diagram, all cross-checked against the Code
Special Occupancies, Locations, and Equipment & Montana Electrical Statutes, Rules, and Licensing
Summarize the classification rules for Class I, II, and III locations, including division definitions and the zone system, and map 15 equipment applications to the correct location class
Identify the requirements for hazardous-location wiring methods, sealing fittings, and boundary seals in 10 scenarios
List the special requirements for health care facilities, assembly occupancies, agricultural buildings, and marinas for 12 given installations
Read the Montana electrical licensing statutes and administrative rules and outline the licensing tiers, journeyman scope of work, supervision ratios, continuing education hours, and renewal cycle
Extract the Montana permit, inspection, and penalty provisions and write the citation for each requirement you list
Your checkpoint
A two-part study sheet: a hazardous-location classification matrix with 15 mapped applications, and a Montana licensing fact sheet with at least 15 cited requirements
Montana Electrical Statutes, Rules, and Licensing & Safety, NFPA 70E, and Job-Site Practices
Answer 30 Montana-specific practice questions on statutes, rules, licensing, permits, and enforcement, and log the source for each correct answer
Build a table of NFPA 70E approach boundaries, arc-flash PPE categories, and the risk assessment procedure, then apply it to 10 field tasks
Write the lockout/tagout and verification sequence for 5 energized-work scenarios, including when energized work is permitted under 70E
List 12 job-site safety practices covering temporary power, GFCI protection on construction sites, ladder use, and confined-space entry
Describe the employer and employee responsibilities under the Montana safety statutes and the electrical worker's duty to report unsafe conditions
Your checkpoint
A 30-question Montana licensing quiz scored at 90 percent or better plus a one-page NFPA 70E boundary and PPE quick-reference card
General Electrical Knowledge and Theory & Grounding, Bonding, and Overcurrent Protection & Branch Circuits, Feeders, and Service Calculations & Motors, Controls, and HVAC Equipment & Montana Electrical Statutes, Rules, and Licensing & Safety, NFPA 70E, and Job-Site Practices
Complete three timed 80-question mixed-domain practice exams and record the score and time for each
Re-study the two lowest-scoring domains from the practice exams and rework every missed calculation from scratch
Drill 40 rapid-fire recall items on ampacity tables, conduit fill, grounding conductor sizing, and motor tables until each is answered in under 30 seconds
Review the Montana licensing fact sheet and NFPA 70E card twice, then self-test on each without notes
Assemble a final one-page formula and table index for exam-day reference practice
Your checkpoint
Three scored practice exams averaging 85 percent or better, a written remediation log for every missed item, and a completed one-page formula index