- Spaulding classification
- System that categorizes medical devices as critical, semicritical, or noncritical based on infection risk, determining required disinfection or sterilization level.
- Standard precautions
- Infection control practices applied to all patients regardless of diagnosis, including hand hygiene, PPE, and safe injection practices.
- Airborne precautions
- Precautions for pathogens transmitted via small droplets that remain suspended in air, requiring N95 respirator and negative-pressure room.
- Hand hygiene moments
- WHO's five indications for hand hygiene: before patient contact, before aseptic procedure, after body fluid exposure, after patient contact, after touching surroundings.
- Sterile field
- Area around a sterile drape where only sterile items may contact; 1-inch border is considered nonsterile.
- Steam sterilization parameters
- Gravity displacement: 121–123°C for 15–30 min; pre-vacuum: 132–134°C for 3–4 min with 20–30 min dry time.
- Ethylene oxide sterilization
- Low-temperature sterilization using EO gas at 37–63°C, 40–80% humidity, 450–1200 mg/L for 1–6 hours, followed by aeration.
- Biological indicators
- Test organisms used to verify sterilization efficacy: Geobacillus stearothermophilus for steam and hydrogen peroxide; Bacillus atrophaeus for EO and dry heat.
- Bowie-Dick test
- Daily test for pre-vacuum steam sterilizers run at 132–134°C for 3.5–4 min in an empty chamber to verify air removal and steam penetration.
- High-level disinfection
- Process that kills all microorganisms except high numbers of bacterial spores, used for semicritical items like endoscopes.
- Immediate-use steam sterilization
- Sterilization of urgently needed items at point of use, not intended as routine reprocessing; requires covered transport and prompt use.
- Instrument inspection
- Visual and functional check of instruments for cleanliness, damage, alignment, and sharpness before packaging and sterilization.
- Scissor sharpness test
- Cut a single layer of test material along full blade length; sharp scissors cut cleanly to the tip without tearing.
- Lumen patency
- Verification that hollow instruments are clear of debris and obstruction, using appropriate-diameter brushes, flush, and borescope inspection.
- Flexible endoscope leak test
- Test performed before and after each procedure to detect damage to the endoscope's outer sheath and internal channels.
- Powered equipment inspection
- Check cords for fraying, test insulation, verify battery function, and follow manufacturer's preventive maintenance schedule.
- Loaner instrument processing
- Inspect, verify function, obtain IFU, and validate cleaning efficacy before processing loaner instruments.
- AAMI ST79
- Comprehensive guidance for steam sterilization in healthcare facilities, covering reprocessing, packaging, and quality assurance.
- OSHA Bloodborne Pathogens Standard
- 29 CFR 1910.1030 requires exposure control plan, hepatitis B vaccination offer, PPE, and post-exposure evaluation.
- Joint Commission infection control
- Accreditation standards requiring written infection prevention plan, surveillance, and annual evaluation.
- FDA sterilant regulation
- Sterilants and high-level disinfectants are regulated as medical devices, requiring premarket notification or approval.
- Record retention
- Sterilization records kept per facility policy and accreditation requirements, often at least 3 years or longer for implantables.
- Glutaraldehyde exposure limit
- NIOSH ceiling limit of 0.05 ppm; use closed containers, local exhaust ventilation, and PPE.
- Ethylene oxide hazard
- Carcinogen and reproductive hazard; requires exposure monitoring and separate ventilated aeration area.
- RACE fire response
- Rescue, Alarm, Confine, Extinguish/Evacuate-standard fire response sequence in healthcare facilities.
- PASS fire extinguisher
- Pull, Aim, Squeeze, Sweep-technique for using a fire extinguisher.
- Biohazardous waste
- Waste contaminated with blood or body fluids; disposed in red bags and sharps containers per regulations.
- Biological indicator failure
- Positive BI requires recall of all items from that load, notification of users, and documentation of corrective actions.
- Load record contents
- Cycle parameters, biological and chemical indicator results, operator ID, and load contents documented for each sterilization cycle.
- Documentation correction
- Use single line, initial, and date; no erasures or white-out; maintain legibility and traceability.
- SBAR communication
- Situation, Background, Assessment, Recommendation-structured hand-off tool for clear communication.
- Just culture
- Patient safety culture encouraging error reporting without blame, while maintaining accountability for reckless behavior.