MOC PQA - Optician flashcards
MOC PQA - Optician · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Diopter definition
- Unit of refractive power equal to the reciprocal of focal length in meters; a 2.00 D lens has a focal length of 0.50 m.
- Prentice's rule
- Prism in diopters equals decentration in centimeters multiplied by lens power in diopters; direction follows the base toward the decentration side for plus lenses.
- Vertex distance formula
- Effective power change is calculated as F_new = F/(1 − d·F), where d is the change in vertex distance in meters; clinically significant above about four diopters.
- Abbe value meaning
- A measure of dispersion; higher Abbe values indicate less chromatic aberration, while lower values produce more color fringing, especially off-axis.
- Boxing system dimensions
- Frame size is written as lens width, bridge width, and temple length; effective diameter is the largest box dimension used to calculate minimum blank size.
- Pantoscopic tilt
- Downward tilt of the lens plane relative to the vertical, typically 8 to 12 degrees; it affects effective power and cylinder in high prescriptions.
- Face-form angle
- Horizontal wrap of the frame front, usually 5 to 8 degrees; excessive wrap induces prism and requires compensated lens design.
- Minimum blank size
- Calculated as effective diameter plus twice the decentration plus about 2 mm edge allowance; inadequate blank size forces unwanted decentration.
- Progressive corridor
- The zone of increasing plus power between distance and near; shorter corridors suit small lens heights but increase peripheral distortion.
- Polycarbonate properties
- Refractive index about 1.586, Abbe value about 30, and high impact resistance; commonly required for children's and safety eyewear.
- Anti-reflective coating
- Multilayer surface treatment that reduces reflections and increases light transmission; typically includes a hard coat and hydrophobic top layer.
- Photochromic limitation
- Lenses darken with ultraviolet exposure; windshields block UV, so they may not darken adequately while driving.
- Transposition rule
- Add cylinder power to sphere, reverse the cylinder sign, and change the axis by 90 degrees; the prescription remains optically equivalent.
- Spherical equivalent
- Sphere power plus half the cylinder power; used for contact lens conversion when cylinder is small or clinically insignificant.
- Monocular PD
- Distance from the bridge of the nose to each pupil, measured separately; the sum gives binocular PD and reduces error from head turn.
- Prism resolution
- Horizontal and vertical prism components combine as vectors; resultant prism equals the square root of the sum of squares.
- Dk and Dk/t
- Dk is oxygen permeability of a contact lens material; Dk/t is transmissibility through a given lens thickness and predicts corneal oxygen supply.
- RGP fit assessment
- Fluorescein pattern shows apical clearance, mid-peripheral bearing, and edge lift; central bearing indicates a flat fit and central pooling a steep fit.
- Peroxide care system
- Hydrogen peroxide disinfection requires a neutralizing case and full soak time; incomplete neutralization causes burning and corneal irritation.
- Acanthamoeba risk
- Exposure to non-sterile water, including tap water, swimming, and showering while wearing lenses, increases risk of this serious corneal infection.
- Corneal refractive power
- The cornea provides about two-thirds of the eye's refractive power, roughly 43 diopters; the crystalline lens contributes about 15 to 20 diopters.
- Axial length and myopia
- Each 1 mm increase in axial length corresponds to roughly 3 diopters of myopia and is associated with increased retinal detachment risk.
- Presbyopia onset
- Age-related loss of accommodative amplitude, typically noticed in the early to mid-40s; add power usually starts near +1.00 diopter.
- Anisometropia effect
- A difference in refractive error between eyes greater than about 2 diopters may cause aniseikonia and adaptation problems with spectacles.
- Lensmeter function
- Instrument that measures sphere, cylinder, axis, prism, and optical center of a lens; calibration should be verified with a known lens.
- Lens clock use
- Device that reads surface curvature in diopters; used to verify base curve and surface power by converting sagitta to power.
- Frame heater caution
- Softens acetate for adjustment; overheating causes blistering and loss of shape, so heat should be applied gradually and evenly.
- Hinge screw matching
- Replacement screws must match thread size and length; mismatched screws damage hinge threads and require tapping or hinge replacement.
- Prescription as record
- A medical document containing prescriber information, date, and expiration; release and retention must follow privacy and record-keeping rules.
- Scope of practice
- Defines which tests and fittings an optician may perform; exceeding scope is a licensing violation and may create liability.
- Informed consent
- Clear communication of risks, alternatives, and costs before a procedure or fitting; documented consent supports patient autonomy and ethical practice.
- Conflict of interest
- Ownership interests, referral arrangements, or incentives that may influence recommendations; must be disclosed and comply with anti-kickback laws.