- Standard Test Conditions
- Irradiance 1000 W/m², cell temperature 25 °C, and AM 1.5 spectrum. Module nameplate power, voltage, and current are rated at STC, so real-world output is usually lower.
- NOCT
- Nominal Operating Cell Temperature measured at 800 W/m², 20 °C ambient, and 1 m/s wind. Typical framed modules reach 42-48 °C, used to estimate real cell temperature.
- Peak sun hours
- Number of hours per day at 1000 W/m² that would deliver the same daily irradiation. A 5 kW array in a 5 PSH location yields about 25 kWh/day before derating.
- Performance ratio
- Ratio of actual AC energy to the theoretical energy from STC array rating times plane-of-array irradiation. It captures temperature, soiling, wiring, and inverter losses; 0.75-0.85 is typical.
- Bypass diode function
- A diode across a module substring that provides an alternate current path when cells are shaded or damaged. It limits power loss and prevents reverse-bias heating of shaded cells.
- Temperature coefficient of power
- Percent change in module power per degree Celsius of cell temperature, typically −0.3 to −0.45 %/°C for crystalline silicon. Hot cells therefore reduce output below STC ratings.
- Fixed tilt orientation
- In the northern hemisphere, modules face true south at a tilt near site latitude. Steeper tilt boosts winter production, shallower tilt boosts summer production.
- Irradiance vs insolation
- Irradiance is instantaneous power per area in W/m². Insolation is energy per area over a period, usually kWh/m²/day, and determines daily energy yield.
- Ohm's law and power
- V = I × R and P = V × I, which also gives P = I²R and P = V²/R. These relationships underpin voltage drop, conductor sizing, and load calculations.
- Series string behavior
- Modules in series add voltages while current stays the same. String current is limited by the lowest-current module, so mismatched or shaded modules reduce total output.
- Parallel connection behavior
- Parallel-connected sources add currents while voltage stays the same. Mismatched parallel strings are limited by the lowest-voltage string and can cause circulating current.
- 1.25 continuous factor
- NEC requires multiplying PV source and output currents by 1.25 for conductor ampacity and overcurrent sizing, treating irradiance-enhanced current as a continuous load.
- DC voltage drop formula
- Vdrop = 2 × L × I × R, where L is one-way length and R is conductor resistance per unit length. The factor two accounts for the round-trip path.
- Energy unit conversions
- 1 kWh equals 1000 Wh and 3.6 MJ. One horsepower is about 0.746 kW. These conversions link utility bills, motor loads, and array sizing.
- Three-phase AC power
- P = √3 × Vline × Iline × power factor for a balanced three-phase load. Single-phase power is simply V × I × power factor.
- Fill factor
- Ratio of maximum power to the product Voc × Isc. A higher fill factor means a squarer I-V curve and a more efficient module, typically 0.7-0.8 for silicon.
- Maximum power point
- The point on the I-V curve where Vmp × Imp is greatest. MPPT electronics continuously adjust operating voltage to track this point as irradiance and temperature change.
- Cold-temperature Voc check
- At the lowest expected ambient temperature, string open-circuit voltage rises and must remain below the inverter maximum DC input voltage, or the inverter can be damaged.
- Hot-temperature Vmp check
- At the highest expected cell temperature, string maximum power voltage falls and must stay above the inverter MPPT minimum, or the inverter drops out of tracking range.
- DC/AC ratio
- Array STC power divided by inverter AC rating. Ratios of 1.1-1.3 are common; when array output exceeds the inverter rating, the inverter clips AC power.
- Depth of discharge
- Fraction of battery capacity withdrawn in a cycle. Lead-acid is typically limited to 50 % for life, while lithium can often use 80-100 % of rated capacity.
- MPPT vs PWM controller
- MPPT controllers track the array maximum power point and allow higher array voltage, gaining output in cool weather. PWM controllers clamp array voltage to battery voltage and are simpler.
- Rapid shutdown
- NEC 690.12 requirement that conductors within 1 ft of the array be limited to 30 V and 240 VA within 30 seconds of shutdown, protecting firefighters.
- Blocking diode
- A diode placed in series with a string or module to prevent reverse current from flowing into a lower-voltage or shaded string, protecting modules from overheating.
- DC arc hazard
- Unlike AC, DC arcs do not self-extinguish at a current zero crossing. Array conductors remain energized whenever illuminated, so DC circuits require rated disconnects and safe work practices.
- Fall protection threshold
- OSHA requires fall protection above 6 ft in general industry and 4 ft in construction. Roof anchors, harnesses, and lanyards are typical PV rooftop measures.
- IV curve tracing
- A commissioning and troubleshooting test that sweeps array voltage and records current. Comparing the traced curve to expected values reveals shading, mismatch, or failed modules.
- Insulation resistance test
- A megohmmeter test applying high DC voltage between conductors and ground to detect insulation degradation, moisture intrusion, or damaged cable before energizing the system.
- Thermal imaging inspection
- Infrared scanning of modules and terminations reveals hot spots, failed bypass diodes, and loose connections that show as temperature anomalies under load.
- Equipment grounding
- Bonding module frames, racking, and inverter enclosures to the grounding electrode system to clear faults and protect personnel, distinct from system conductor grounding.
- String current comparison
- Measuring each string's current under equal irradiance; a string reading about 10 % low suggests soiling, a bad connection, or a failed module substring.
- Maintenance torque check
- Periodically verifying termination torque on lugs, combiners, and module clamps prevents loose connections that cause resistance heating, voltage drop, and arc faults.