NATE Gas Heating Service · Give each week a clear focus.

8 weeks · About 7 hours per week

Week 1

Combustion Theory and Gas Fundamentals

  • Define the three legs of the combustion triangle and explain what happens to flame shape and CO output when each leg is starved.

  • Calculate stoichiometric air required for natural gas and propane using their respective heating values and air-fuel ratios, and compute percent excess air from a measured CO2 or O2 reading.

  • Convert between Btu, therms, and cubic feet of gas, and compute input rate from a timed meter clocking at a given manifold pressure.

  • Distinguish complete from incomplete combustion by interpreting flame color, lift, flashback, and yellow tipping, and state the cause of each.

  • Explain dew point of flue products and why condensing versus non-condensing appliances tolerate different stack temperatures.

Your checkpoint

A one-page formula sheet plus 10 worked combustion math problems (air-fuel ratio, excess air, input rate, derated altitude input) solved with units shown, scored at 90% or better on self-check.

Week 2

Venting and Combustion Air

  • Classify venting categories I through IV by pressure and temperature and match each to appliance types and approved vent materials.

  • Size a Category I natural-draft vent connector and chimney using the appliance input, connector rise, and height, and identify when a common vent is prohibited.

  • Compute required combustion air for a confined space using the two-permanent-opening method and the known-air-infiltration method, and state when a confined space becomes unconfined.

  • Explain the difference between spillage, backdrafting, and blocked-flue conditions, and list the test steps and instruments used to detect each.

  • Identify code requirements for termination clearances, vent slope, and condensation drainage on condensing appliances.

Your checkpoint

Two fully worked venting scenarios - one confined-space combustion air calculation and one Category I vent sizing with termination clearances listed - each documented on a single annotated worksheet.

Week 3

Gas Piping, Valves, and Burner Components

  • Trace the gas path from meter to burner, naming every safety and control device in order and stating each device's function.

  • Size a gas supply line using the longest-run method and the appropriate capacity table for the fuel's specific gravity and pressure drop.

  • Explain the operation of a redundant combination gas valve, including the regulator, safety shutoff, and operator sections, and describe the manifold pressure adjustment procedure.

  • Identify burner components - orifice, manifold, spuds, primary and secondary air shutters - and describe the symptom of a mis-sized or clogged orifice.

  • Perform and document a leak test on new piping and describe the pressure and duration requirements for the test.

Your checkpoint

A labeled gas-train diagram from meter to burner with device functions, plus a pipe-sizing calculation for a three-appliance branch layout showing each segment's load and selected diameter.

Week 4

Ignition, Safety Controls, and Electrical Interface

  • Describe the ignition sequence of a hot-surface and a spark-to-pilot system, listing the safety timing windows (pre-purge, trial for ignition, flame-establishing period, post-purge) and what happens on failure at each step.

  • Explain flame rectification, including why the flame sensor needs a clean surface, why polarity and grounding matter, and how to measure microamp signal.

  • Read a ladder diagram and a manufacturer wiring schematic and trace the call for heat through the safety chain to the gas valve.

  • Test the limits of a rollout switch, high-limit, pressure switch, and flame rollout circuit, and explain how each interrupts the safety chain.

  • Demonstrate safe electrical troubleshooting practice: lockout/tagout, meter usage, and verifying 24 V control versus line voltage.

Your checkpoint

A written ignition-sequence timeline for both ignition types with expected voltage or microamp readings at each step, verified against at least three manufacturer manuals, plus a completed schematic-tracing exercise for one fault scenario.

Week 5

Airflow, Heat Exchangers, and Temperature Rise & Combustion Theory and Gas Fundamentals

  • Measure static pressure across the air handler and in the supply and return plenums, and compute total external static pressure.

  • Calculate temperature rise from supply and return temperatures and compare it to the data plate range, then determine whether airflow must be increased or decreased.

  • Interpret a blower performance table to select the correct speed tap for a target CFM at a measured static pressure.

  • Explain how a restricted heat exchanger or dirty evaporator coil changes temperature rise and what combustion symptoms accompany it.

Your checkpoint

A completed airflow diagnostic worksheet: static pressure readings, computed temperature rise, blower table selection, and a written recommendation for one simulated low-airflow case.

Week 6

Startup, Combustion Analysis, and Troubleshooting & Venting and Combustion Air

  • Perform a combustion analysis with an electronic analyzer: zero and calibrate the instrument, sample before and after the heat exchanger, and record O2, CO, CO2, stack temperature, and draft.

  • Calculate steady-state efficiency and excess air from analyzer readings, and interpret CO air-free versus as-measured values.

  • Diagnose five common faults from symptoms alone: delayed ignition, flame rollout, short cycling, pilot outage, and high CO with normal draft.

  • Verify draft in the vent connector and at the appliance outlet and determine whether a draft reading indicates spillage or an over-draft condition.

  • Write a customer-facing explanation of combustion test results that avoids jargon while remaining accurate.

Your checkpoint

A combustion analysis report for one appliance (real or simulated) with all readings, calculated efficiency, air-free CO, pass/fail judgment against manufacturer limits, and a corrective-action list.

Week 7

Gas Piping, Valves, and Burner Components & Ignition, Safety Controls, and Electrical Interface

  • Build a troubleshooting decision tree for 'no heat' that branches on thermostat call, induced-draft proving, ignition attempt, flame sensing, and gas valve operation.

  • Practice meter-based diagnosis of a pressure switch that will not close and a flame sensor reading below the manufacturer's minimum microamp threshold.

  • Verify manifold pressure and gas input on a running appliance and identify the adjustment and measurement points on a combination valve.

  • Describe the correct procedure for replacing a gas valve, including leak testing, clocking the meter afterward, and combustion re-verification.

  • List the documentation required after a repair: combustion readings, leak test, temperature rise, and any de-rating for altitude.

Your checkpoint

A one-page decision tree for 'no heat' with at least eight decision nodes and the expected meter reading at each branch, plus a written step-by-step gas valve replacement and re-verification procedure.

Week 8

Combustion Theory and Gas Fundamentals & Venting and Combustion Air & Gas Piping, Valves, and Burner Components & Ignition, Safety Controls, and Electrical Interface & Airflow, Heat Exchangers, and Temperature Rise & Startup, Combustion Analysis, and Troubleshooting

  • Complete a timed 100-question practice set weighted by domain percentage and score each domain separately to identify remaining weak areas.

  • Re-study the two lowest-scoring domains using the week 1–7 deliverables as reference notes.

  • Recite from memory the key code limits: combustion air volumes, vent termination clearances, pipe sizing pressure drop, and temperature rise tolerance.

  • Rehearse the combustion analysis and static pressure procedures end to end without notes to confirm procedural fluency.

Your checkpoint

A scored 100-question practice exam with a per-domain breakdown, a written remediation list for any domain below 75%, and a signed readiness statement listing the three procedures you can now perform unassisted.

Milestones

Week 2: Score 85% or better on a self-made 25-question quiz covering combustion math and venting/combustion air, with all calculation steps shown and no formula sheet lookup for the air-fuel and excess-air formulas.

Week 4: Trace a call for heat through a real schematic in under 5 minutes and correctly state the expected microamp range and the failure behavior at each ignition step, verified against a manufacturer manual.

Week 6: Produce a complete combustion analysis report with calculated steady-state efficiency within 2% of the analyzer's internal calculation and a correct pass/fail judgment against manufacturer CO limits.

Week 8: Achieve 80% or better overall on the timed 100-question practice exam, with no single domain below 70% and both originally weakest domains improved by at least 10 percentage points.