NOCE / ABO Basic study materials
NOCE / ABO Basic study resources

NOCE / ABO Basic common mistakes

NOCE / ABO Basic · Understand the traps and how to avoid them.

Mistake 1

When given keratometry readings and a spectacle prescription, labels the steeper corneal meridian as the plus-cylinder axis or assigns the axis to the wrong meridian.

Memorizes with-the-rule/against-the-rule phrases instead of drawing the corneal cross and relating the steep meridian to the minus-cylinder axis.

What to do instead

Draw a cross for the two meridians, mark the steeper one, and apply the convention that the minus-cylinder axis lies along the flatter meridian; practice ten K-to-Rx conversions.

Mistake 2

Uses centimeters or drops signs when substituting into thin-lens or vergence formulas, or applies a vertex-distance correction in the wrong direction for plus versus minus powers.

The formula is memorized as symbols without unit and sign discipline, which high-power items expose.

What to do instead

Convert every distance to meters, write the sign convention at the top of the scratch paper, and sanity-check the result: moving a plus lens away from the eye increases its effective plus power.

Mistake 3

Transposes a prescription by changing the cylinder sign but forgets to add or subtract 90 degrees to the axis, or mistakenly adds 90 degrees to the sphere.

Under time pressure the candidate uses a shortcut without checking each of the three transposition steps.

What to do instead

Use a fixed three-step method: new sphere equals old sphere plus old cylinder; new cylinder is the same magnitude with opposite sign; new axis is old axis plus or minus 90 degrees modulo 180, then verify meridional powers are unchanged.

Mistake 4

Selects the highest-index lens for every prescription without checking Abbe value, impact resistance, density, or coating compatibility.

Equates thinness with the best optical and safety outcome, but exam items ask for trade-offs among thickness, color fringing, and impact performance.

What to do instead

Compare index, Abbe value, density, impact category, and prescription power; choose based on the stated priority and explicitly state the trade-off.

Mistake 5

Confuses A, B, DBL, and temple measurements, or treats A plus DBL as the patient's PD without accounting for frame difference and optical center placement.

Memorizes abbreviations but not what each dimension defines on the boxing rectangle.

What to do instead

Sketch the boxing rectangle: A is horizontal lens size, B is vertical lens size, DBL is bridge width, ED is effective diameter; compute frame PD as A plus DBL and compare it with the patient's distance PD.

Mistake 6

Verifies finished eyewear by reading only sphere power and skips axis, prism, optical centration, or edge and thickness checks.

Final inspection is rushed and the lensmeter is used in only one meridian.

What to do instead

Use a written verification sequence: neutralize sphere, cylinder, and axis; mark the optical center; measure PD and OC height; check prism, edge thickness, and coatings; then sign off.

Mistake 7

Bends temples or endpieces to stop a frame from sliding or tilting before checking bridge and side symmetry, and without supporting the frame.

Treats the symptom before diagnosing frame alignment and risks bending solder joints or stressing lenses.

What to do instead

Follow an adjustment sequence: inspect and align the frame flat, adjust the bridge and sides, then temples, then nosepads; support the frame at the bridge and make small incremental changes.

Mistake 8

Mixes impact-resistance categories by treating basic dress eyewear as high-impact, or confuses drop-ball and high-velocity test requirements.

Standards are memorized as labels without linking them to lens material, thickness, marking, and intended use.

What to do instead

Build a table of lens material, minimum thickness, impact test, and marking; tie each row to dress eyewear, children's eyewear, and safety eyewear.

Mistake 9

Converts a spectacle prescription directly to a contact lens power without considering vertex distance, base curve, or over-refraction.

Assumes the same power applies at the corneal plane and ignores the tear lens and fitting relationship.

What to do instead

Start from keratometry and base-curve selection, compensate vertex distance for higher powers, perform an over-refraction, and verify the fit before finalizing the contact lens power.

Mistake 10

Quotes insurance benefits or delivery dates before verifying eligibility, or fails to document patient instructions and warranty terms.

Focuses on closing the sale and treats administrative details as an afterthought.

What to do instead

Use a checklist to verify benefits and authorization, record the quote and promised dates, and document dispensing instructions and warranty terms in writing.