BC-HIS study materials
BC-HIS study resources

BC-HIS cheat sheet

BC-HIS · Keep the key ideas within reach.

Quick reference

Basic Sciences and Acoustics

  • Sound is a longitudinal pressure wave; frequency (Hz) determines pitch and amplitude (dB) determines loudness.

  • dB SPL = 20 log10(P/P0), with P0 = 20 micropascals; dB IL = 10 log10(I/I0), with I0 = 10^-12 W/m^2.

  • dB HL is referenced to normative human thresholds (ANSI S3.6), so 0 dB HL differs in SPL at each frequency.

  • Wavelength in meters = 343 / f (Hz); a 1000 Hz tone has a wavelength of about 0.343 m.

  • Doubling distance from a point source in free field reduces intensity by 6 dB (inverse square law).

  • Adding two equal, uncorrelated sound sources increases total level by 3 dB; two coherent sources can add up to 6 dB.

  • Resonance occurs when a system is driven at its natural frequency, amplifying output near that frequency.

  • The speech spectrum peaks near 500 Hz for vowels; consonant energy is concentrated above 2000 Hz.

  • Human audibility spans roughly 20 Hz to 20,000 Hz, with greatest sensitivity between 1000 and 4000 Hz.

Quick reference

Anatomy and Physiology of the Auditory System

  • The outer ear (pinna and ear canal) provides roughly 10-15 dB of gain in the 2000-5000 Hz region.

  • The tympanic membrane area (~55 mm^2 effective) versus stapes footplate (~3.2 mm^2) yields a pressure gain of about 17:1.

  • The ossicular lever ratio is approximately 1.3:1; combined with the area ratio, middle ear gain totals about 25-30 dB.

  • The acoustic reflex is mediated by the stapedius muscle (CN VII) and typically occurs at 70-90 dB SL, with a latency near 100 ms.

  • The cochlea is a tonotopically organized spiral; the base responds to high frequencies and the apex to low frequencies.

  • Outer hair cells provide active cochlear amplification (the cochlear amplifier), sharpening tuning and producing otoacoustic emissions.

  • Inner hair cells are the primary afferent sensory cells, synapsing with roughly 90-95% of type I auditory nerve fibers.

  • The auditory nerve (CN VIII) travels via the internal auditory meatus to the cochlear nucleus; the first brainstem synapse is ipsilateral.

  • The stria vascularis generates the endocochlear potential of about +80 mV relative to perilymph.

Quick reference

Disorders of Hearing and Audiologic Assessment

  • Conductive loss shows air-bone gaps with normal bone conduction; sensorineural loss shows air and bone thresholds within 10 dB.

  • Pure-tone average (PTA) typically averages thresholds at 500, 1000, and 2000 Hz.

  • Degree categories: normal (<=25 dB HL), mild (26-40), moderate (41-55), moderately severe (56-70), severe (71-90), profound (>90).

  • The speech banana spans roughly 250-8000 Hz at 30-60 dB HL; high-frequency loss preferentially degrades consonant perception.

  • Word recognition scores below 50% in quiet suggest poor amplification benefit and warrant counseling on expectations.

  • Otoscopy precedes testing to rule out cerumen impaction, perforation, or drainage that contraindicates ear impressions.

  • Tympanometry: Type A peak near 0 daPa, Type B flat (effusion or perforation), Type C negative peak (<-100 daPa, Eustachian dysfunction).

  • Acoustic reflexes are absent in severe-to-profound cochlear loss and elevated or absent in retrocochlear pathology.

  • Presbycusis most commonly presents as bilateral, symmetric, high-frequency sensorineural loss with reduced speech-in-noise ability.

Quick reference

Hearing Instrument Technology and Electroacoustics

  • ANSI/ASA S3.22 specifies measurement of saturation output (OSPL90), full-on gain, frequency response, and harmonic distortion.

  • OSPL90 is the maximum output with 90 dB SPL input; it must not exceed the patient's uncomfortable loudness level.

  • Gain is the difference between output and input SPL at a specified frequency and input level.

  • Peak gain typically occurs near 2500-3000 Hz for a standard behind-the-ear coupling; venting reduces low-frequency gain.

  • Harmonic distortion should be below 3% at 500 and 800 Hz and below 5% at 1600 Hz per S3.22.

  • Equivalent input noise (EIN) below 30 dB SPL is considered acceptable for hearing instruments.

  • Feedback occurs when loop gain exceeds unity; reduced by venting changes, occlusion, and phase cancellation or gain limiting.

  • Directional microphones improve the signal-to-noise ratio by roughly 3-5 dB in typical diffuse noise environments.

  • Compression knee point is the input level at which gain reduction begins; compression ratio = input change / output change above knee.

Quick reference

Hearing Instrument Fitting, Verification, and Follow-Up Care

  • Prescriptive targets (NAL-NL2, DSL v5) derive gain from audiometric thresholds, coupling, and patient-specific factors.

  • Real-ear measurement compares the aided ear canal SPL to prescriptive targets; probe-tube placement is typically 5 mm from the eardrum.

  • Real-ear aided response (REAR), real-ear occluded response (REOR), and real-ear insertion gain (REIG) are key verification measures.

  • The speech intelligibility index (SII) ranges 0-1 and estimates audibility of the speech spectrum through the aided response.

  • Aided speech recognition should be compared with unaided performance; no improvement warrants troubleshooting or adjustment.

  • The 30-day trial period is common practice; follow-up visits typically occur at 1-2 weeks, 1 month, and 3 months.

  • Hearing aid fitting in children requires DSL v5 targets and verification with real-ear-to-coupler difference (RECD).

  • Validation measures include the COSI, APHAB, and IOI-HA, which quantify self-perceived benefit and satisfaction.

  • Earmold or dome selection must balance venting and occlusion; excessive occlusion produces the occlusion effect below 500 Hz.

Quick reference

Professional, Ethical, and Regulatory Practice

  • The FDA regulates hearing aids as Class I medical devices; a medical evaluation is required before fitting adults unless the patient signs a waiver.

  • Patients under 18 years require a physician evaluation (preferably ENT) before hearing aid fitting.

  • Hearing aid dispensers must be licensed per state law; licensure requirements and scope of practice vary by state.

  • The ASHA or AAA Code of Ethics prohibits misrepresentation of credentials and requires informed consent and confidentiality.

  • HIPAA governs the privacy of protected health information; audiologic records are subject to its safeguards.

  • The FTC Hearing Aid Rule requires a user instructional brochure and a receipt with a 30-day return policy statement.

  • Binaural fitting is standard of care for bilateral loss unless contraindicated by asymmetry or medical factors.

  • Dispensing records must be retained per state and federal requirements; documentation supports continuity of care.

  • Conflict-of-interest disclosure is required when the dispenser benefits financially from a product recommendation.