NBEO Part III flashcards
NBEO Part III · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Pinhole test purpose
- Determines whether reduced visual acuity is due to refractive error; improvement suggests refractive cause, no improvement suggests ocular media or retinal/neural cause.
- Snellen 20/20 definition
- A letter subtending 5 arc minutes at 6 meters (20 feet); each detail subtends 1 arc minute; represents normal central visual acuity.
- Jackson cross-cylinder technique
- Uses a ±0.25 D cross-cylinder to refine astigmatism; axis checked with JCC at 45° to correcting axis; power checked with JCC aligned to axis.
- Duochrome test principle
- Red and green targets compared; in emmetropia they appear equally clear; red clearer indicates myopia (add minus); green clearer indicates hyperopia (add plus).
- Cycloplegic refraction indication
- Used in children, accommodative esotropia, and patients with unreliable manifest refraction; cyclopentolate 1% or atropine 1% paralyzes accommodation.
- Keratometry measurement
- Measures anterior corneal curvature over central 3 mm; average K ~43.00 D; astigmatism calculated as difference between steep and flat meridians.
- Cover test interpretation
- Cover one eye and observe uncovered eye; movement indicates deviation; recovery movement after uncover distinguishes phoria from tropia.
- Near point of convergence
- Target moved toward nose until patient reports diplopia or one eye deviates; normal break <5 cm and recovery <7 cm; receded NPC suggests convergence insufficiency.
- Worth 4-dot test
- Red-green glasses with 4 dots; 4 dots indicates fusion; 2 red indicates left suppression; 3 green indicates right suppression; 5 dots indicates diplopia.
- Hirschberg test
- Corneal light reflex displacement from pupil center estimates strabismus; 1 mm displacement ≈ 7° or ~15 prism diopters deviation.
- Stereopsis normal value
- Randot or Titmus test; normal stereoacuity is 40-60 seconds of arc; absence suggests monocular vision, suppression, or strabismus.
- Van Herick technique
- Slit lamp grading of peripheral anterior chamber depth; grade 0-4; grade ≤2 indicates shallow AC and risk of angle closure glaucoma.
- Seidel test
- Fluorescein applied to suspected corneal wound; streaming aqueous humor indicates full-thickness laceration; positive test requires urgent referral.
- Sclerotic scatter illumination
- Broad beam at limbus; light scattered through cornea reveals subtle opacities, edema, and epithelial defects.
- Retroillumination technique
- Light reflected from iris or fundus; highlights corneal endothelial guttata, pigment deposits, and lens opacities.
- Indirect ophthalmoscopy image
- Condensing lens (20 D or 28 D) with headset; produces inverted, reversed, real image; wide field for peripheral retina evaluation.
- Cup-to-disc ratio
- Ratio of optic cup diameter to disc diameter; normal ≤0.5; asymmetry >0.2 between eyes or CDR ≥0.6 warrants glaucoma evaluation.
- ISNT rule
- Neuroretinal rim thickness order: Inferior > Superior > Nasal > Temporal; violation suggests glaucomatous damage.
- Amsler grid purpose
- 10 cm grid at 33 cm; detects central 10° metamorphopsia and scotomas; used in macular degeneration monitoring.
- Goldmann applanation tonometry
- Measures IOP by flattening corneal area of 3.06 mm diameter; normal 10-21 mmHg; affected by central corneal thickness.
- Central corneal thickness effect
- Thin CCT (<500 µm) underestimates true IOP; thick CCT (>600 µm) overestimates; pachymetry needed for accurate interpretation.
- Shaffer gonioscopy grading
- Grades angle width from 0 (closed) to 4 (wide open); grade ≤2 indicates narrow angle and risk of closure.
- Glaucomatous visual field defect
- Nasal step, arcuate scotoma, paracentral scotoma, or altitudinal defect; respects horizontal midline; confirmed with repeat testing.
- Humphrey reliability indices
- Fixation losses, false positives, and false negatives should be <33%; higher values indicate unreliable field test requiring repeat.
- Soft contact lens fit
- Centration, full corneal coverage, 0.5-1.0 mm movement with blink, no limbal compression; push-up test assesses tightness.
- RGP fluorescein pattern
- Apical clearance or alignment, edge lift 0.1-0.2 mm, and centration; pattern guides base curve adjustment.
- Tear film breakup time
- Normal >10 seconds; <5 seconds indicates dry eye; may contraindicate contact lens wear and warrants tear supplementation.
- Vertex distance formula
- Effective power change = (F × d)/(1 - dF); compensate when refractive error exceeds ±4.00 D or when switching between spectacles and contact lenses.
- Prentice rule
- Prism diopters = decentration in cm × lens power in diopters; used to calculate induced prism from lens decentration.
- Spherical equivalent
- Sphere power + half cylinder power; used for rough estimation and contact lens conversion.
- Cyclopentolate 1% properties
- Anticholinergic cycloplegic; onset 30-60 minutes; duration 6-24 hours; used for cycloplegic refraction in children.
- Punctal occlusion technique
- After instilling drops, press on lacrimal sac for 1-2 minutes; increases ocular absorption and reduces systemic side effects.