NC Plumbing Contractor flashcards
NC Plumbing Contractor · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Qualifying individual
- The person who meets the experience requirement and passes the licensing exam; the contractor's license is held by the business but tied to this individual.
- P-2 plumbing license
- A limited North Carolina plumbing contractor classification restricted to residential work on one- and two-family dwellings, narrower than the unlimited P-1 license.
- Plumbing permit
- Official authorization from the local inspections department that must be obtained before plumbing work starts, triggering required rough-in and final inspections.
- State code preemption
- The NC State Building Code, including the plumbing code, is adopted statewide, so local governments enforce it but cannot adopt less stringent local plumbing rules.
- Fixture unit
- A numerical measure of the load-producing effect a fixture places on the drainage system or of the probable water demand it creates in the supply system.
- Flood level rim
- The top edge of a fixture or receptacle from which water will overflow onto the floor or surrounding area; used to set air gaps and backwater protection.
- Air gap
- The unobstructed vertical distance through free atmosphere between the lowest opening of a waste or water outlet and the flood level rim of the receiving fixture.
- Minimum drainage pipe size
- No drainage pipe, fixture drain, or branch may be installed smaller than one and one-quarter inch nominal diameter under the plumbing code.
- Drainage pipe slope
- Horizontal drainage pipe 2-1/2 inches and smaller must slope at 1/4 inch per foot; pipe 3 inches and larger must slope at 1/8 inch per foot.
- Trap seal depth
- The vertical depth of the water seal in a fixture trap, required to be at least 2 inches and not more than 4 inches.
- Trap arm length
- The developed length from the fixture outlet to the vent connection, limited by drain size: 1-1/4 in = 5 ft, 1-1/2 in = 6 ft, 2 in = 8 ft, 3 in = 12 ft, 4 in = 16 ft.
- Vent terminal height
- A vent stack must extend at least 6 inches above the roof surface and must be located away from windows, doors, and outdoor air intakes.
- Maximum static pressure
- Pressure at fixtures may not exceed 80 psi; where the supply exceeds that, a pressure-reducing valve must be installed ahead of the distribution system.
- T and P relief setting
- A water heater temperature and pressure relief valve is set to open at or below 210 degrees F or 150 psi, with a full-size gravity discharge.
- Thermal expansion control
- A closed water system created by a check valve, pressure-reducing valve, or backflow preventer requires a thermal expansion tank or approved expansion control device.
- Water service minimum size
- Building water service pipe must be at least 3/4 inch nominal, while individual fixture supply piping may be reduced to 1/2 inch minimum.
- Water closet clearances
- A water closet needs at least 15 inches from its centerline to any sidewall or partition and at least 21 inches of clear space in front of the bowl.
- Toilet flush volume limit
- Water closets installed in new or altered work may not exceed 1.6 gallons per flush, and urinals may not exceed 1.0 gallon per flush.
- Washer standpipe height
- A clothes washer standpipe must be at least 2 inches in diameter and must terminate between 18 and 30 inches above the trap weir.
- Trap primer purpose
- A trap primer adds water to a floor drain or similar trap to replace evaporation and prevent sewer gas from entering the building through a dry seal.
- Reduced pressure zone assembly
- A testable backflow preventer with two check valves and a relief valve, required for high-hazard connections and installed above grade and accessible.
- Minimum air gap size
- The air gap must be at least 1 inch or twice the effective opening of the outlet, whichever dimension is greater, measured above the flood level rim.
- Grease interceptor requirements
- A grease interceptor must be sized for the connected fixture flow, vented, accessible for cleaning, and must receive only kitchen waste, not sanitary or storm drainage.
- Hose bibb protection
- Hose bibbs and sillcocks must be protected against backflow with a vacuum breaker or an approved backflow device to prevent cross-connection.
- Isometric riser reading
- On a plumbing isometric, vertical lines represent risers and the angled lines represent horizontal runs, with 45-degree offsets showing combined horizontal and vertical change.
- Gallons per cubic foot
- One cubic foot of water contains 7.48 gallons; this factor converts a calculated pipe or tank volume into gallons for system volume and chlorination calculations.
- Psi to feet of head
- Multiply pressure in psi by 2.31 to obtain feet of head, or divide feet of head by 2.31 to obtain psi for pressure and elevation calculations.
- Trench cubic yards
- Multiply length by width by depth in feet and divide by 27 to obtain cubic yards of excavation; add allowances for bedding, backfill, and soil swell.
- Claim of lien deadline
- In North Carolina a mechanics lien claim must be filed within 120 days after the claimant last furnished labor or materials to the improved property.
- Notice to lien agent
- A subcontractor or supplier on a project with a designated lien agent must give written notice to that agent within 15 days after first furnishing labor or materials.
- Performance bond
- A surety bond guaranteeing the contractor will complete the work according to the contract; it protects the owner, while a payment bond protects subcontractors and suppliers.
- Retainage
- A percentage, commonly 5 percent, withheld from each progress payment until substantial completion or punch list closeout to protect the owner against incomplete work.