NC Roofing Contractor · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Square (roofing unit)
A unit of roof area equal to 100 square feet. Used to order shingles, underlayment, and labor; always add waste factor for hips, valleys, and complex geometry.
ASTM D3462
Standard specification for asphalt shingles made from glass felt and surfaced with mineral granules. Defines minimum physical and performance requirements for shingle products.
Ice dam protection membrane
Self-adhering waterproof membrane installed at eaves to prevent water backup from ice dams. Required by IRC where average January temperature is 25°F or below or ice damming has occurred.
EPDM membrane
A thermoset single-ply rubber roofing membrane with excellent weathering and ozone resistance. Seams are joined with contact adhesive or splice tape, not heat welding.
TPO membrane
Thermoplastic polyolefin single-ply membrane, hot-air welded at seams. Resists UV and chemicals; weld quality is verified by probe or air-lance testing after installation.
Pitch multiplier
Factor equal to the square root of one plus the rise-over-twelve squared. Multiplies plan area to obtain actual sloped roof area for material takeoff.
Headlap
The overlap of a shingle course over the course below, measured from the top edge. Determines exposure and weathertightness; specified by the manufacturer.
Exposure
The exposed height of each shingle course, equal to shingle length minus headlap. Standard three-tab shingles use five-inch exposure; architectural shingles vary.
Step flashing
L-shaped metal flashing installed in courses interleaved with shingles at sidewalls. Prevents water intrusion where a roof plane meets a vertical wall.
Cricket
A small sloped roof structure built behind a chimney wider than 30 inches to divert water around it. Prevents water pooling and leakage at the chimney.
Drip edge
Metal flashing at eaves and rake edges that directs water away from the fascia and deck. Installed under underlayment at eaves and over it at rakes.
Net free vent area
Open area of attic vents, required at 1:150 of attic floor area, or 1:300 when intake and exhaust are balanced with a vapor retarder present.
Class A roof covering
Highest fire-resistance rating under ASTM E108, indicating severe fire exposure resistance. Commonly required for new construction in many jurisdictions.
Ponding water
Water remaining on a low-slope roof 48 hours after rain. Caused by inadequate slope, clogged drains, or deck deflection; may require structural evaluation.
Blister (roofing)
A raised area on a low-slope membrane caused by trapped moisture or air. Repair requires cutting, drying, and patching, not surface coating.
Call-back rate
Percentage of completed jobs requiring return visits for warranty or defect issues. A key business performance metric reflecting installation quality.
Change order
A written, signed amendment to the contract adjusting scope, price, or schedule. Verbal changes are a leading cause of payment disputes.
Retainage
A percentage of progress payments withheld by the owner until substantial completion. Commonly five to ten percent; affects contractor cash flow.
Claim of lien
A recorded statement asserting a contractor's right to payment secured by the property. In North Carolina, must be filed within 120 days of last furnishing.
Notice to Lien Agent
A written notice filed by a contractor to preserve lien rights on a project with a lien agent. Required under North Carolina lien law.
Statute of repose
A time limit after substantial completion within which construction defect claims must be brought. North Carolina uses six years for improvements to real property.
UDTP claim
Unfair or deceptive trade practices claim under N.C.G.S. 75-1.1. Can expose a contractor to treble damages and attorney fees.
NCLBGC
North Carolina Licensing Board for General Contractors. Issues and disciplines general contractor licenses, including roofing specialty classifications.
Qualifying individual
The person who passes the licensing exam and meets experience requirements, allowing a business entity to hold a contractor license.
Continuing education requirement
North Carolina requires eight hours of continuing education annually for license renewal, including mandatory hours on licensing laws and safety.
Fall protection threshold
OSHA requires fall protection at six feet or more above a lower level for construction work. Roofing near edges requires guardrails, nets, or personal fall arrest.
Personal fall arrest system
Harness, lanyard, and anchor assembly that stops a fall. Anchorage must be rated 5,000 pounds per worker or engineered equivalent, with prompt rescue.
Warning line system
Barrier set back at least 15 feet from a low-slope roof edge. Alone it is not fall protection unless combined with a safety monitoring system.
Ladder 4:1 rule
Extension ladders are set at a 4:1 slope, one foot out for every four feet of height, with three feet extending above the landing.
Safety Data Sheet
Document summarizing hazards, handling, and first aid for roofing adhesives, sealants, and solvents. Must be available on site under hazard communication rules.
Low-slope roof
A roof with a slope less than 2:12, typically using membrane systems such as EPDM, TPO, PVC, or built-up roofing rather than shingles.
Standing seam metal roof
Architectural metal roof with raised seams and concealed clips. Allows thermal movement; fastener and clip detailing must accommodate expansion and contraction.