Resilient flooring
A floor covering that recovers from indentation, including vinyl sheet and tile, linoleum, rubber, cork, and VCT.
Tufted carpet
Carpet made by punching yarn through a primary backing and locking it with a secondary backing; the most common carpet construction.
PEI wear rating
A tile wear scale from I to V, where I is no foot traffic and V is heavy commercial; used to match tile to use.
Laminate flooring
A floating composite floor with a wear layer, printed decor layer, HDF core, and backing; it is not solid wood and usually cannot be refinished.
Engineered wood flooring
A floor with a plywood core and a real wood veneer top; it has limited refinishing life compared with solid wood.
Fall protection threshold
OSHA 29 CFR 1926 Subpart M requires fall protection at 6 ft or more in construction, including open edges and shafts.
Silica dust control
Cutting concrete or tile releases carcinogenic silica; OSHA 1926.1153 requires wet cutting or dust collection and may require a written exposure plan.
SDS requirement
Safety Data Sheets must be on site for each chemical, and workers must be trained on hazards under OSHA Hazard Communication.
Knee pad use
Knee pads or kneeling boards reduce cumulative trauma from prolonged kneeling on hard substrates, an ergonomic hazard in flooring work.
Concrete flatness tolerance
Resilient flooring typically requires 1/8 in. in 10 ft flatness, checked with a 10-ft straightedge; some products allow 3/16 in.
ASTM F2170
An in-situ relative humidity test for concrete slabs; results are compared with the adhesive and flooring manufacturer's moisture limit.
ASTM F1869
A calcium chloride test that measures concrete moisture vapor emission rate, typically limited to 3 lb/1000 sq ft/24 hr.
CSP surface profile
The ICRI Concrete Surface Profile scale from 1 to 10; CSP 3-5 is typical for adhesive bonding of resilient flooring.
Wood subfloor moisture
Wood subfloor moisture content should be within 2-4% of the flooring's moisture content before installation, checked with a moisture meter.
Stretch-in carpet method
Carpet installed over tack strip and cushion and stretched with a power stretcher; required for rooms over about 30 ft.
Tack strip
Wood strip with angled pins nailed around the perimeter; carpet is stretched over it and tucked into the gully.
VCT installation
Vinyl composition tile set in pressure-sensitive or hard-set adhesive, then rolled with a 100-lb roller after adhesive flash-off.
Thin-set mortar
A cementitious adhesive applied with a notched trowel for ceramic and porcelain tile; notch size depends on tile size.
Floating floor
A floor not fastened to the subfloor, such as laminate or some wood, requiring a perimeter expansion gap and transition profiles.
3-4-5 squaring method
A layout method using a 3-ft and 4-ft leg with a 5-ft diagonal to establish a 90-degree corner; scale up for larger rooms.
Carpet waste factor
Add 10-15% to carpet quantity for waste, more for patterned carpet with a match; carpet is estimated by the square yard.
Tile waste factor
Add 10% waste for field tile and 15-20% for diagonal or mosaic layouts to account for cuts and breakage.
Adhesive coverage
The square feet per gallon stated on the product label; divide total area by coverage and round up to full containers.
Change order
A signed document recording scope, cost, and schedule changes; work should not proceed until it is signed.
Pile direction
The orientation of carpet pile; all rolls in a room should run the same direction to avoid shading differences at seams.
Adhesive open time
The period after spreading adhesive during which flooring must be laid; exceeding it causes poor bond and requires re-spreading.
Subfloor deflection limit
Ceramic tile typically requires L/360 or stiffer and stone often L/720; verify with the tile manufacturer and joist span tables.
Confined space entry
Crawl spaces and subfloor voids may require atmosphere testing and permit-required confined-space procedures when triggered.
Heat-welded seam
A seam in sheet vinyl or linoleum made by routing a groove, inserting welding rod, and trimming flush after cooling.
Carpet tile quarter-turn
A carpet tile layout where each tile is rotated 90 degrees from its neighbor, hiding seams; common in commercial installations.
Crack isolation membrane
A membrane per ANSI A118.12 that isolates substrate cracks from tile; uncoupling membranes decouple tile from substrate movement.
As-built drawings
Drawings that record actual installed conditions; they are part of project closeout along with warranties and attic stock.