NCCER HVACR study materials
NCCER HVACR study resources

NCCER HVACR key terms

NCCER HVACR · Get comfortable with the vocabulary.

Psychrometrics

The study of the properties of moist air, including dry-bulb temperature, wet-bulb temperature, humidity ratio, and enthalpy. Technicians use it to predict how air behaves as it is heated, cooled, humidified, or dehumidified.

Related: Dry-bulb temperature, Wet-bulb temperature, Sensible heat
Dry-bulb temperature

The temperature of air measured by an ordinary thermometer with a dry sensing element. It reflects only sensible heat and does not account for moisture content or evaporative cooling effects.

Related: Wet-bulb temperature, Psychrometrics
Wet-bulb temperature

The lowest temperature air can reach through evaporative cooling, measured with a thermometer whose bulb is kept wet and moving. It combines dry-bulb temperature and humidity and is used to check refrigerant charge.

Related: Dry-bulb temperature, Psychrometrics, Superheat
Sensible heat

Heat that changes the temperature of a substance without changing its state. In air conditioning it is the portion of the load that raises or lowers room temperature, measured in Btu per hour.

Related: Latent heat, Psychrometrics
Latent heat

Heat absorbed or released when a substance changes state at constant temperature, such as refrigerant boiling or water vapor condensing. In comfort cooling it is the energy removed when moisture condenses on a coil.

Related: Sensible heat, Enthalpy
Enthalpy

The total heat content of a substance per unit mass, combining sensible and latent energy. On a psychrometric chart it is read along slanted lines and used to calculate total coil load.

Related: Latent heat, Sensible heat, Psychrometrics
Ton of refrigeration

A cooling capacity equal to 12,000 Btu per hour, roughly the heat needed to melt one ton of ice in 24 hours. Equipment capacity and load estimates are commonly stated in tons.

Related: British thermal unit, Load calculation
British thermal unit

The amount of heat required to raise one pound of water one degree Fahrenheit. It is the basic unit for expressing heating and cooling quantities in North American HVACR work.

Related: Ton of refrigeration, Sensible heat
Load calculation

A room-by-room estimate of heat gain and heat loss used to size equipment and ducts. It accounts for insulation, windows, occupancy, appliances, infiltration, and local design temperatures.

Related: Manual J, Ton of refrigeration
Manual J

A widely recognized residential load calculation method published by the Air Conditioning Contractors of America. It produces room-by-room heating and cooling loads used to select equipment and design duct systems.

Related: Load calculation, Manual D
Manual D

A residential duct design method that sizes ducts from the equipment airflow and the pressure available after subtracting component losses. It helps ensure correct room airflow and acceptable static pressure.

Related: External static pressure, Load calculation
Lockout/tagout

A required safety procedure in which an energy-isolating device is locked and tagged so equipment cannot be energized while someone services it. Only the person who applied the lock removes it.

Related: Personal protective equipment, Arc flash
Personal protective equipment

Wearable gear that reduces injury risk, such as safety glasses, gloves, hearing protection, and arc-rated clothing. Selection depends on the hazard present at the specific task and site.

Related: Lockout/tagout, Arc flash
Arc flash

A sudden release of energy caused by an electrical fault through air, producing intense heat, light, and pressure. It can occur without contact and requires shock and flash hazard assessment before work.

Related: Lockout/tagout, Multimeter
Multimeter

A test instrument that measures voltage, resistance, and often current and continuity. Choosing the correct function and range before touching probes prevents meter damage and personal injury.

Related: Clamp meter, Continuity
Clamp meter

A meter that measures current by surrounding a single conductor with a split jaw, avoiding a series connection. It is useful for checking compressor and fan motor amp draw against nameplate ratings.

Related: Multimeter, Locked rotor amps
Manifold gauge set

A tool with two gauges and valves that connects to service ports to read system pressures and to add or remove refrigerant. Hoses and gauges must be rated for the refrigerant in use.

Related: Superheat, Subcooling, Vacuum pump
Vacuum pump

A pump used to evacuate air, nitrogen, and moisture from a sealed system before charging. A deep vacuum verified with a micron gauge confirms the system is dry and leak-free.

Related: Micron gauge, Manifold gauge set
Micron gauge

An electronic instrument that measures very low absolute pressure during evacuation. Readings in microns show whether moisture has been removed and whether the vacuum holds.

Related: Vacuum pump, Non-condensable gas
Recovery machine

Equipment that removes refrigerant from a system and stores it in a recovery cylinder for reuse, recycling, or reclamation. Venting refrigerant to the atmosphere is prohibited by federal regulation.

Related: Recovery cylinder, Section 608
Refrigeration cycle

The repeating process in which refrigerant absorbs heat at low pressure and rejects it at high pressure. Its four stages are compression, condensation, expansion, and evaporation.

Related: Compressor, Condenser, Evaporator, Metering device
Compressor

The component that raises refrigerant pressure and temperature by squeezing vapor and moving it through the circuit. Common types include reciprocating, scroll, and rotary, each with different service considerations.

Related: Refrigeration cycle, Locked rotor amps, Superheat
Condenser

The coil where high-pressure refrigerant vapor rejects heat to outdoor air or water and condenses into liquid. Dirty coils or poor airflow raise head pressure and reduce capacity.

Related: Subcooling, Refrigeration cycle, Head pressure
Evaporator

The indoor coil where low-pressure liquid refrigerant boils and absorbs heat from the airstream. Its temperature must stay above freezing to avoid icing under normal operating conditions.

Related: Superheat, Refrigeration cycle, Latent heat
Metering device

A restriction such as a thermostatic expansion valve, fixed orifice, or capillary tube that drops refrigerant pressure between the condenser and evaporator. It also regulates the flow of liquid refrigerant.

Related: Thermostatic expansion valve, Superheat, Refrigeration cycle
Thermostatic expansion valve

A modulating metering device that controls refrigerant flow to maintain a set superheat at the evaporator outlet. It responds to bulb temperature and evaporator pressure through a diaphragm.

Related: Superheat, Metering device, Evaporator
Superheat

The temperature of refrigerant vapor above its saturation temperature at a given pressure. Measured at the evaporator outlet, it confirms the refrigerant is fully boiled before reaching the compressor.

Related: Subcooling, Thermostatic expansion valve, Saturation temperature
Subcooling

The temperature of liquid refrigerant below its saturation temperature at a given pressure. Measured at the condenser outlet, it indicates how much liquid is stacked in the condenser and helps verify charge.

Related: Superheat, Condenser, Saturation temperature
Saturation temperature

The temperature at which a refrigerant boils or condenses at a specific pressure. Technicians compare it with line temperature to find superheat and subcooling values.

Related: Superheat, Subcooling
Head pressure

The high-side pressure read at the compressor discharge or condenser. It rises with high outdoor temperature, dirty coils, or non-condensable gas and affects compressor load and efficiency.

Related: Condenser, Non-condensable gas
Non-condensable gas

Air or nitrogen trapped in a refrigerant circuit that does not condense at normal condenser temperatures. It raises head pressure, causes high subcooling readings, and must be removed by evacuation.

Related: Head pressure, Vacuum pump, Micron gauge
Section 608

The federal Clean Air Act rule governing refrigerant handling, recovery, leak repair, and technician certification. It sets requirements for ozone-depleting and substitute refrigerants in stationary equipment.

Related: Recovery machine, Recovery cylinder
Recovery cylinder

A refillable, DOT-approved vessel used to hold refrigerant removed from equipment. It must not be filled beyond the marked capacity and must be identified with the refrigerant it contains.

Related: Recovery machine, Section 608
Combustion air

The air supplied to a fuel-burning appliance for complete burning of gas or oil. Inadequate supply causes carbon monoxide production and is a common cause of unsafe operation.

Related: Carbon monoxide, Draft
Carbon monoxide

A colorless, odorless gas produced by incomplete combustion that can cause illness or death. Technicians test for it in flue gas and ambient air and check for proper venting.

Related: Combustion air, Draft
Draft

The movement of flue gases out of an appliance and up a vent or chimney. It may be produced by natural buoyancy or by a fan, and it must be verified so gases do not spill into the space.

Related: Combustion air, Carbon monoxide
Thermocouple

A pair of dissimilar metal wires that generates a small voltage when heated, used to prove a pilot flame is present. A weak signal typically prevents the gas valve from opening.

Related: Thermopile, Ignition sequence
Thermopile

A group of thermocouples connected in series that produces enough millivolts to power a gas valve. It is common on standing-pilot heating equipment and is tested under load.

Related: Thermocouple, Ignition sequence
Ignition sequence

The ordered steps a control board follows to start a burner, such as proving draft, energizing the igniter, opening the gas valve, and sensing flame. Understanding it guides diagnosis of no-heat calls.

Related: Thermocouple, Flame sensor
Flame sensor

A rod that uses flame rectification to tell the control board a burner is lit. A dirty or corroded sensor causes short cycling or lockout because the board cannot confirm flame.

Related: Ignition sequence, Lockout/tagout
Heat pump

A reversible system that moves heat into a space for heating and out of it for cooling by changing refrigerant flow direction. Its heating capacity drops as outdoor temperature falls.

Related: Reversing valve, Defrost cycle, Refrigeration cycle
Reversing valve

A four-way valve that switches refrigerant flow direction in a heat pump, swapping the roles of the indoor and outdoor coils. A failure can leave the system stuck in one mode.

Related: Heat pump, Defrost cycle
Defrost cycle

A timed or demand-initiated mode in which a heat pump temporarily reverses to melt frost from the outdoor coil. Controls terminate defrost based on temperature or pressure to avoid overheating.

Related: Heat pump, Reversing valve
External static pressure

The resistance to airflow measured across the blower and components of an air handler, expressed in inches of water column. High readings indicate restrictive filters, coils, or undersized ducts.

Related: Manual D, Airflow
Airflow

The volume of air moved through a system per unit time, usually stated in cubic feet per minute. Proper airflow is required for capacity, efficiency, and safe equipment operation.

Related: External static pressure, Manual D
Charge

The amount of refrigerant contained in a system. It is verified by weight, superheat, subcooling, or sight glass depending on the metering device and system type.

Related: Superheat, Subcooling, Manifold gauge set
Locked rotor amps

The current a motor draws when its rotor cannot turn, typically several times running current. Comparing measured amps with nameplate values helps diagnose compressor and fan failures.

Related: Clamp meter, Compressor
Continuity

A test that confirms an electrical path is complete with very low resistance. It is used to check switches, fuses, and wiring while the circuit is de-energized.

Related: Multimeter, Lockout/tagout