Home Inspection Standards of Practice
A standards-of-practice document defines the minimum observed systems and components, the scope of the walk-through, and the exclusions; it is not a code-compliance or warranty document.
Core inspectable systems typically include roof, exterior, structure, plumbing, electrical, heating, cooling, insulation/ventilation, and interior; inspectors report on what is visible and readily accessible.
Inspectors are generally not required to move stored goods, dismantle equipment, enter unsafe areas, or predict remaining service life; concealed conditions are outside the standard scope.
Report language should distinguish observed deficiency from cause and from remedy; the standard requires describing the condition, not designing repairs.
Typical exclusions: cosmetic finishes, underground piping, wells and septic beyond visible components, low-voltage systems, and environmental testing (mold, radon, asbestos).
A written report must identify inspected items, deficiencies observed, and any systems or components not inspected with the reason; client signature and date of inspection are standard elements.
A pre-inspection agreement should state scope, limitations, fee, and any limitation-of-liability or arbitration clause permitted by the jurisdiction.
Inspection standards are minimums; an inspector may exceed them, but the report should state when a component was not inspected or was inspected beyond the standard.
Roofing
Asphalt shingles: typical life 15-25 years (3-tab) and 20-30 years (architectural); inspect for granule loss, curling, clawing, and exposed fasteners.
Slope rule: shingles require a minimum 2:12 slope with underlayment; below 2:12 use low-slope membranes.
Flashing points to check: valleys, step flashing at walls, counterflashing, chimney flashing, and kick-out flashing at roof-wall terminations.
Roof penetrations: boots and collars at plumbing vents, seals at skylights, and proper clearance of flue pipes above the roof surface.
Attic-side clues: water stains on sheathing, rusted fasteners, daylight through the deck, sagging rafters, and deteriorated or missing underlayment.
Drainage: gutters should slope toward downspouts; downspouts discharge away from the foundation; check for gutter separation and debris dams.
Flat/low-slope roofs: look for ponding, blisters, seam separation, and flashing height; membrane roofs need positive drainage.
Report roof by material, approximate age if known, observed condition, and any limitations (e.g., not walked due to pitch or weather).
Structure and Exterior Systems
Foundation types: slab-on-grade, crawlspace, and basement; look for differential settlement, step cracks in masonry, and horizontal cracks indicating lateral pressure.
Crack interpretation: hairline shrinkage cracks are common; wide, offset, or stair-step cracks in block walls suggest movement and warrant further evaluation.
Siding and cladding: check for proper clearance above grade (typically 6-8 inches), proper lap, and moisture intrusion at penetrations.
Decks: ledger attachment to the house, flashing above the ledger, joist hangers, diagonal bracing, and guardrail height and baluster spacing are common defect points.
Grading should slope away from the foundation; negative grade and downspout discharge near the foundation are common moisture sources.
Structural members: look for notched or bored joists, cut rafters, missing collar ties, and improper alterations that affect load path.
Exterior stairs and handrails: check attachment, tread condition, and graspable handrails; guardrails should resist a concentrated load at the top rail.
Report observed structural defects as conditions requiring evaluation by a qualified engineer or contractor; the inspector does not perform engineering analysis.
Plumbing
Water supply: check for leaks at supply lines, valves, and fixtures; note water pressure and flow at multiple fixtures.
Drainage: test fixtures for slow drains and gurgling; check traps at fixtures and proper venting; look for S-traps and missing cleanouts.
Water heater: check TPR valve and discharge pipe termination, flue draft for gas units, seismic strapping where required, and signs of tank corrosion.
Supply piping materials: copper, PEX, CPVC, galvanized steel; note polybutylene and galvanized steel as potential concerns.
Drain piping: ABS, PVC, cast iron, and galvanized; look for leaks, improper slope, and bellies in accessible sections.
Fixtures: check for active leaks, loose toilets, caulking at tubs and showers, and evidence of past leaks (staining, efflorescence).
Water heater TPR discharge should terminate within 6 inches of the floor or to the exterior; it must not be capped or reduced in size.
Report the type and location of the main water shutoff and the main fuel shutoff for the client.
Electrical and HVAC Systems
Service panel: check for double-tapped breakers, missing knockouts, improper bonding, and panel labeling; note the service amperage and main disconnect.
GFCI protection is required in bathrooms, kitchens, garages, outdoors, and near water; test with the test button and report non-functioning devices.
AFCI protection is required in bedrooms and other living areas in newer construction; note absence in older homes as an observation.
Receptacles: test for open ground, reversed polarity, and open neutral; check for proper cover plates and box fill.
HVAC: check furnace operation, filter condition, flue draft, and clearance to combustibles; check AC for cooling, condensate drainage, and refrigerant line insulation.
Heating equipment: identify fuel type, venting, and combustion air; look for rust, soot, and flame roll-out evidence.
Cooling equipment: check for ice on coils, condensate leaks, and proper disconnect; note age of equipment and any visible damage.
Report electrical and HVAC deficiencies as observations; recommend evaluation by a licensed electrician or HVAC technician for safety issues.
Interior
Interior doors and windows: check operation, latches, and glazing; note broken seals (fogging) in insulated glass units.
Stairs and handrails: check tread and riser consistency, handrail height, and guardrail spacing; report loose or missing components.
Walls and ceilings: look for cracks, water stains, and evidence of patching; note any areas not visible due to stored items or finishes.
Fireplaces: check damper operation, firebox condition, hearth clearance, and visible chimney components; recommend a Level II inspection when appropriate.
Attic access: check for proper insulation, ventilation, and evidence of moisture or pest activity; report limitations if access is restricted.
Bathrooms: check for proper ventilation (fan or window), caulking, and evidence of moisture at tubs, showers, and toilets.
Kitchen: check for proper venting of range hood, GFCI protection at counter receptacles, and condition of cabinets and countertops.
Report interior deficiencies with location and description; distinguish cosmetic items from safety or functional concerns.
Insulation, Ventilation and Inspection Business/Ethics
Attic insulation: check depth, type, and coverage; note compressed or missing insulation and proper baffles at eaves.
Ventilation: check for proper intake and exhaust; soffit and ridge vents should not be blocked; bath and kitchen exhaust should terminate outdoors.
Crawlspace: check for vapor barrier, ventilation, and evidence of moisture; report standing water or excessive debris.
Insulation R-values vary by climate zone; report the observed type and approximate depth rather than asserting code compliance.
Business: the pre-inspection agreement should define scope, limitations, fee, and payment terms; maintain records and insurance.
Ethics: avoid conflicts of interest, disclose referral relationships, and do not perform repairs on properties inspected within the jurisdiction's prohibited period.
Report writing: use clear, objective language; avoid alarming or vague statements; include photos and location descriptions where possible.
Continuing education and adherence to the standards of practice support competence and defensibility; document limitations in every report.