NCLE Advanced key terms
NCLE Advanced · Get comfortable with the vocabulary.
- Base curve
- Related: Sagittal depth, Peripheral curve, Fluorescein pattern
The radius of curvature of the central posterior surface of a contact lens, given in millimeters. A shorter radius makes a steeper lens that fits more tightly against the cornea.
- Diameter
- Related: Sagittal depth, Lens decentration
The overall width of a contact lens measured across its widest point in millimeters. Diameter affects corneal coverage, centration, and how the lens interacts with the eyelids.
- Sagittal depth
- Related: Base curve, Diameter, Scleral lens
The height of a lens's posterior surface measured from the plane of its edge to the center. It describes how deeply the lens vaults over the cornea and drives fit relationships.
- Optical zone
- Related: Peripheral curve, Aspheric lens
The central portion of a contact lens that carries the corrective power and sits over the pupil. Its width affects visual quality and how the lens behaves on the eye.
- Peripheral curve
- Related: Edge lift, Optical zone
A flattening curve near the edge of a rigid lens, outside the optical zone. It controls edge clearance and tear exchange and influences comfort.
- Edge lift
- Related: Peripheral curve, Fluorescein pattern
The gap between the posterior edge of a rigid lens and the cornea. Enough lift lets tears flow beneath the lens; too much causes discomfort and lens instability.
- Rigid gas permeable lens
- Related: Dk/t, Fluorescein pattern, Corneal warpage
A rigid lens made of a material that transmits oxygen. It keeps its own shape on the eye and can correct irregular astigmatism by creating a tear layer over the cornea.
- Soft toric lens
- Related: Prism ballast, Over-refraction
A soft lens with toric surfaces, plus a design feature that keeps the cylinder axis from rotating. It corrects astigmatism while retaining the comfort of a hydrogel material.
- Prism ballast
- Related: Soft toric lens
A stabilization method that adds thickness or prism to the lower part of a toric soft lens. Gravity and lid forces then hold the lens axis in the correct orientation.
- Aspheric lens
- Related: Optical zone, Base curve
A lens whose surface curvature changes steadily from center to edge instead of having a single radius. It is used to reduce spherical aberration and shape the fit.
- Reverse geometry lens
- Related: Rigid gas permeable lens, Corneal topography
A rigid lens whose second curve is steeper than its central base curve. It is used in orthokeratology to reshape the corneal epithelium and temporarily reduce myopia.
- Scleral lens
- Related: Sagittal depth, Corneal topography
A large-diameter rigid lens that lands on the sclera and vaults over the cornea, trapping a pool of tears. It is used for irregular corneas, dry eye, and high refractive errors.
- Dk/t
- Related: Hypoxia, Corneal edema
The oxygen transmissibility of a lens, found by dividing the material's oxygen permeability (Dk) by its thickness. Higher values mean more oxygen reaches the cornea.
- Keratometry
- Related: Corneal topography, Base curve
Measurement of the curvature of the central anterior cornea, reported in diopters across two principal meridians. It guides initial lens selection and reveals corneal astigmatism.
- Corneal topography
- Related: Keratometry, Scleral lens
A computer-generated map of corneal curvature and elevation over a broad area. It helps detect irregular astigmatism, choose specialty designs, and monitor change over time.
- Fluorescein pattern
- Related: Edge lift, Base curve, Corneal staining
The pattern of dye-stained tears seen beneath a rigid lens under blue light with a yellow filter. It shows areas of bearing, pooled clearance, and edge lift.
- Over-refraction
- Related: Soft toric lens, Lens decentration
A refraction done with the contact lens still on the eye. It measures leftover refractive error and tells the fitter how to adjust the lens power.
- Lens decentration
- Related: Diameter, Over-refraction, Tight lens syndrome
An off-center resting position of a contact lens. It can reduce comfort or vision and often points to a fit that is too steep, too flat, or poorly stabilized.
- Tight lens syndrome
- Related: Corneal edema, Lens decentration
A painful, red eye with an immobile lens, corneal edema, and diminished tears. It follows a lens that fits too tightly, particularly after overnight wear.
- Corneal neovascularization
- Related: Hypoxia, Dk/t
Growth of new blood vessels into the clear cornea, which is normally vessel-free. It usually results from chronic low oxygen or mechanical rubbing from lens wear.
- Corneal edema
- Related: Hypoxia, Tight lens syndrome
Fluid buildup that swells the cornea, commonly from reduced oxygen or poor tear exchange under a lens. It causes haze, halos, and blurred vision.
- Giant papillary conjunctivitis
- Related: Protein deposit, Replacement schedule
An inflammatory reaction of the upper inner eyelid with enlarged papillae. It is linked to lens deposits, rough edges, and mechanical irritation, and causes itching and lens intolerance.
- Microbial keratitis
- Related: Wear schedule, Rub-and-rinse
A corneal infection that can threaten sight. It is associated with extended wear and poor hygiene and shows up as pain, redness, discharge, and a corneal infiltrate.
- Corneal staining
- Related: Fluorescein pattern, Multi-purpose solution
Uptake of fluorescein dye by damaged corneal surface cells from lens wear. Grading its size, depth, and pattern helps separate mechanical, hypoxic, and solution-related causes.
- Corneal warpage
- Related: Rigid gas permeable lens, Keratometry
A reversible change in corneal shape caused by long-term rigid lens wear. It produces spectacle blur and distorted keratometry and topography readings.
- Hypoxia
- Related: Dk/t, Corneal edema, Corneal neovascularization
A shortfall in the oxygen reaching the cornea. With lenses it comes from low oxygen transmissibility or thick designs and can lead to edema and new blood vessels.
- Protein deposit
- Related: Rub-and-rinse, Enzymatic cleaner
A layer of tear-derived protein clinging to a lens surface. Left in place, it causes discomfort, blurred vision, and inflammatory reactions.
- Enzymatic cleaner
- Related: Protein deposit, Replacement schedule
A tablet or solution that breaks down protein that routine daily cleaners leave behind. It is used at set intervals, such as weekly, on soft lenses as directed.
- Multi-purpose solution
- Related: Rub-and-rinse, Hydrogen peroxide system
One product that cleans, rinses, disinfects, and stores soft lenses. It depends on surfactants and preservatives and works best when lenses are rubbed and rinsed first.
- Hydrogen peroxide system
- Related: Multi-purpose solution, Corneal staining
A care system that uses hydrogen peroxide to disinfect lenses. The peroxide must be completely neutralized, usually by a coated disc or tablet, before the lens goes on the eye.
- Rub-and-rinse
- Related: Multi-purpose solution, Protein deposit
The manual cleaning step in which solution and friction are applied to a lens before storage. It lifts deposits and organisms that soaking alone leaves behind.
- Replacement schedule
- Related: Wear schedule, Protein deposit
The recommended interval for throwing away and replacing lenses, such as daily, every two weeks, or monthly. Following it limits deposit buildup and reduces complications.
- Wear schedule
- Related: Replacement schedule, Microbial keratitis
The prescribed pattern of lens use, including daily wear time and whether lenses stay in overnight. It shapes oxygen exposure and the risk of complications.
- Informed consent
- Related: Record retention
Explaining the risks, benefits, and alternatives of contact lens wear and confirming the patient agrees before fitting begins. The discussion is documented in the record.
- Prescription release
- Related: Parameters verification, Record retention
The rule that a patient must receive their contact lens prescription after a fitting so they can buy lenses from any source. It supports patient choice.
- Record retention
- Related: Informed consent, Parameters verification
The length of time patient records, including lens parameters and follow-up findings, must be kept. It is set by state law and professional guidelines.
- Bloodborne pathogens standard
- Related: Informed consent
OSHA rules for infection control in health care settings, covering gloves, hand hygiene, and safe disposal of contaminated items. It protects staff and patients from bloodborne disease.
- Parameters verification
- Related: Prescription release, Base curve
Confirming a delivered lens matches the ordered power, base curve, diameter, and material before it is dispensed. It prevents dispensing errors and remakes.