- Nominal CMU dimensions
- A standard concrete masonry unit is nominally 8 in. x 8 in. x 16 in. but actually measures 7-5/8 in. x 7-5/8 in. x 15-5/8 in., allowing a 3/8 in. mortar joint to reach the 8 in. module.
- ASTM C90
- The standard specification for loadbearing concrete masonry units. It sets minimum compressive strength, absorption, and dimensional tolerances for units used in structural masonry walls.
- ASTM C129
- The standard specification for nonloadbearing concrete masonry units. These units are used in partitions and veneer where structural load resistance is not required.
- ASTM C140
- The test method for sampling and testing concrete masonry units. It covers compressive strength, absorption, density, and dimensional measurements used to verify compliance with specifications.
- Type M mortar
- The highest-strength mortar type, with a minimum compressive strength of 2500 psi. It is used for below-grade and severe-exposure masonry where maximum strength and durability are needed.
- Type S mortar
- A moderate-high strength mortar with a minimum compressive strength of 1800 psi. It is commonly used at grade and in masonry where lateral strength is important.
- Type N mortar
- A general-purpose mortar with a minimum compressive strength of 750 psi. It is the typical choice for above-grade, non-severe exposure masonry walls and veneer.
- f'm
- The specified compressive strength of masonry, determined by the unit strength method or by prism testing. It is the design value used in structural masonry calculations.
- Coarse vs. fine grout
- Coarse grout uses 1/2 in. maximum aggregate and is used where grout space is at least 2 in. Fine grout uses 3/8 in. aggregate for narrower spaces.
- Grout compressive strength
- Masonry grout must achieve a minimum compressive strength of 2000 psi at 28 days. This value is specified in TMS 602 and verified by testing.
- Flashing height above grade
- Exterior masonry flashing must extend at least 8 in. vertically above finished grade. It must include a drip edge and be integrated with weep holes for drainage.
- Weep hole spacing
- Weep holes are placed at a maximum of 32 in. on center and no more than 16 in. above the flashing line. They allow water collected on the flashing to drain out.
- Control joint spacing
- Control joints in concrete masonry are spaced at 20 to 25 ft maximum, or 1-1/2 to 2-1/2 times the wall height, whichever is less. They are also placed at openings and corners.
- Face shell thickness
- Standard hollow concrete masonry units have face shells at least 1-1/4 in. thick. Grouted cells require at least 2 in. of clear space between face shells.
- Vertical reinforcement minimum
- The minimum vertical reinforcement bar size in typical reinforced concrete masonry walls is a No. 4 bar. Lap splices are commonly 40 bar diameters or per TMS 602 tables.
- Mortar joint thickness
- Standard mortar joints in concrete masonry are 3/8 in. thick. This dimension is the difference between nominal and actual unit dimensions, maintaining the module.
- Paver base depth
- Aggregate base for pavers is at least 4 in. for pedestrian use, 6 to 8 in. for vehicular use, compacted in lifts to at least 95% density.
- Bedding sand thickness
- The bedding sand layer under interlocking pavers is 1 in. after compaction, installed with a screed. It should not exceed 1-1/2 in. to avoid rutting.
- Paver thickness
- Interlocking concrete pavers are at least 2-3/8 in. (60 mm) thick for pedestrian areas, 2-3/4 in. (70 mm) for residential driveways, and 3-1/8 in. (80 mm) for commercial vehicular areas.
- Edge restraint
- A rigid edge restraint, such as a concrete curb or aluminum edge, is pinned at 8 to 12 in. on center. It prevents paver migration under vehicular loads.
- Joint sand
- Joint sand fills the 1/8 to 1/4 in. gaps between pavers. It is typically ASTM C144 or C33 sand; polymeric sand is used for stabilization and must be installed dry.
- Drainage slope
- Paved hardscape surfaces must slope at least 1% (1/8 in. per foot) away from structures, with 2% typical. Positive drainage to a defined outfall is required.
- Subgrade compaction
- Native soil subgrade must be proof-rolled and compacted to at least 95% standard Proctor density. Organic material and unstable soils must be removed before base installation.
- SRW base embedment
- Segmental retaining wall base courses are embedded at least 6 in. below grade, and 12 in. for walls over 4 ft. A leveling pad of compacted aggregate is required.
- Geogrid reinforcement
- Geogrid layers reinforce segmental retaining walls when wall height or surcharge exceeds unreinforced limits. Grid layers are placed at design spacing and embedded in compacted backfill.
- PICP base
- Permeable interlocking concrete pavement uses open-graded aggregate base and joint aggregate. A storage reservoir is sized for the design storm; dense-graded base is not used.
- Proof rolling
- Proof rolling is the process of rolling the subgrade with a loaded truck to identify soft or unstable areas. Weak spots must be removed and replaced before base installation.
- Compaction lift thickness
- Aggregate base is compacted in lifts of 2 to 4 in. Thicker lifts may not achieve the required 95% density throughout the layer.
- Leveling pad
- A compacted aggregate leveling pad is placed beneath the first course of a segmental retaining wall. It provides a stable, level base for wall construction.
- Weep holes vs. drainage
- Weep holes drain water from behind masonry veneer, while hardscape drainage relies on surface slope and subsurface drains. Both prevent water accumulation and damage.
- Permeable joint aggregate
- Open-graded aggregate in PICP joints allows water to infiltrate between pavers. It must meet the specified gradation and be free of fines that would clog the system.
- Base aggregate gradation
- Aggregate base for pavers typically meets a dense-graded specification such as ASTM D2940. Gradation affects compaction, permeability, and load distribution.