- GPU Direct Storage (GDS)
- Related: GPUDirect RDMA, NVIDIA Magnum IO, Checkpoint
A path that lets GPUs read and write storage directly, bypassing the CPU and host memory bounce buffer. It lowers latency and CPU load for data-heavy AI pipelines such as checkpoint loading and dataset streaming.
- GPUDirect RDMA
- Related: NCCL, InfiniBand, RoCEv2
A capability that lets a network adapter transfer data straight into or out of GPU memory over PCIe, skipping host memory copies. It reduces latency and CPU overhead in multi-node training communication.
- NCCL
- Related: All-Reduce, NVLink, GPUDirect RDMA
NVIDIA's collective communication library used by distributed training frameworks. It implements all-reduce, all-gather, broadcast, and similar operations, choosing rings, trees, and transport paths automatically based on detected topology.
- NVLink
- Related: NVSwitch, NCCL, PCIe Gen5
A high-bandwidth GPU-to-GPU interconnect that lets accelerators share memory traffic without going through PCIe. On multi-GPU servers it forms the fast fabric used for model-parallel and data-parallel collectives.
- NVSwitch
- Related: NVLink, Topology Awareness, NCCL
A switch chip that connects many GPUs in one server at full NVLink bandwidth, creating an all-to-all fabric. It allows any GPU pair to communicate without PCIe bottlenecks or topology-dependent detours.
- InfiniBand
- Related: Subnet Manager, RDMA, RoCEv2
A low-latency, high-throughput switched network standard widely used for AI training clusters. It offers remote direct memory access, credit-based flow control, and fabric management through a subnet manager.
- RoCEv2
- Related: PFC (Priority Flow Control), ECN (Explicit Congestion Notification), InfiniBand
RDMA over Converged Ethernet version 2, which carries RDMA traffic over routable UDP/IP Ethernet networks. It requires careful configuration of priority flow control and congestion control to avoid packet loss.
- PFC (Priority Flow Control)
- Related: RoCEv2, ECN (Explicit Congestion Notification), Lossless Fabric
An Ethernet link-level mechanism that pauses a specific traffic class instead of the whole port. It prevents RDMA packet drops on lossless RoCE fabrics but can spread congestion if misconfigured.
- ECN (Explicit Congestion Notification)
- Related: RoCEv2, PFC (Priority Flow Control), DCQCN
An IP-level signal in which switches mark packets rather than dropping them when queues build. Endpoints then slow down, which is the preferred congestion control method on RoCE networks.
- Subnet Manager
- Related: InfiniBand, Fat-Tree Topology, ibstat
The InfiniBand fabric service that discovers nodes, computes routes, and programs switch forwarding tables. Without an active subnet manager, an InfiniBand fabric cannot pass traffic between ports.
- Fat-Tree Topology
- Related: Rail-Optimized Network, Bisection Bandwidth, Subnet Manager
A hierarchical switch layout in which every host reaches every other host through the same number of hops at full bisection bandwidth. It is the standard design for large GPU training clusters.
- Rail-Optimized Network
- Related: Fat-Tree Topology, NCCL, Bisection Bandwidth
A cabling scheme where each server's Nth GPU port connects to the same leaf switch group as every other server's Nth GPU. It keeps collective traffic local to a rail and reduces cross-switch hops.
- Bisection Bandwidth
- Related: Fat-Tree Topology, All-Reduce, Rail-Optimized Network
The total network capacity available between two equal halves of a cluster. It sets the ceiling for all-reduce throughput when many nodes exchange gradients at the same time.
- All-Reduce
- Related: NCCL, Ring All-Reduce, Bisection Bandwidth
A collective operation in which every participant ends with the same reduced result, such as a summed gradient. It is the dominant communication pattern in data-parallel training and drives network sizing decisions.
- Ring All-Reduce
- Related: All-Reduce, NCCL, Gradient Accumulation
An algorithm that arranges workers in a logical ring and passes partial sums in two phases, reduce-scatter then all-gather. Its cost scales with message size and is largely independent of worker count.
- PCIe Gen5
- Related: PCIe Bifurcation, NVLink, GPU Direct Storage (GDS)
The fifth PCI Express generation, offering roughly 32 gigatransfers per second per lane. It provides the host bandwidth needed for current data-center GPUs and high-speed network adapters.
- PCIe Bifurcation
- Related: PCIe Gen5, Topology Awareness, NUMA Node
Splitting a physical PCIe slot's lanes into multiple independent links, for example x16 into two x8 links. It lets a server host more GPUs or NICs but can reduce per-device bandwidth.
- NUMA Node
- Related: CPU Affinity, PCIe Bifurcation, Topology Awareness
A group of CPU cores with locally attached memory and PCIe devices. Placing a process and its GPU on the same NUMA node avoids slower cross-socket memory access during data transfers.
- CPU Affinity
- Related: NUMA Node, Slurm, Topology Awareness
Pinning a process or thread to specific CPU cores so it runs consistently on chosen hardware. In GPU workloads it keeps data-loader threads near the memory and PCIe devices they use.
- Topology Awareness
- Related: NVLink, NUMA Node, NCCL
The ability of software to detect how GPUs, CPUs, and network adapters are physically connected and schedule communication accordingly. It avoids routing traffic across slower links when faster paths exist.
- MIG (Multi-Instance GPU)
- Related: GPU Partitioning, Time-Slicing, GPU Operator
A mode that partitions one physical GPU into isolated instances, each with dedicated memory and compute slices. It lets multiple users or jobs share an accelerator with predictable quality of service.
- Time-Slicing
- Related: MIG (Multi-Instance GPU), GPU Operator, Kubernetes Device Plugin
A GPU sharing method in which multiple workloads take turns using the whole device. It improves utilization for light jobs but gives no memory isolation and can cause unpredictable latency.
- GPU Operator
- Related: Kubernetes Device Plugin, NVIDIA Container Toolkit, DCGM
A Kubernetes operator that deploys and manages GPU software components such as drivers, the container toolkit, device plugin, and monitoring agents. It automates lifecycle work that would otherwise be manual per node.
- NVIDIA Container Toolkit
- Related: GPU Operator, CUDA Compatibility, Container Image
Software that exposes host GPUs to containers by integrating with container runtimes. It injects the driver libraries and device nodes a container needs without installing a full driver inside the image.
- CUDA Compatibility
- Related: NVIDIA Container Toolkit, nvidia-smi, Driver Branch
The rules governing which driver versions can run which CUDA toolkit builds. Newer toolkits generally need a minimum driver, while forward compatibility packages allow newer CUDA on older data-center drivers.
- Driver Branch
- Related: CUDA Compatibility, nvidia-smi, Fabric Manager
A release line of the NVIDIA data-center driver, such as a long-lived production branch or a newer feature branch. Mixing branches across nodes in one cluster can cause inconsistent behavior.
- Fabric Manager
- Related: NVSwitch, Driver Branch, nvidia-smi
A service required on systems using NVSwitch that configures the GPU fabric and keeps it consistent. It must be started after the driver loads, and version mismatches with the driver cause startup failures.
- nvidia-smi
- Related: DCGM, XID Error, Driver Branch
A command-line utility that reports GPU inventory, utilization, memory use, temperature, and errors, and can set application clocks. It is the first diagnostic tool for most GPU node issues.
- DCGM
- Related: nvidia-smi, XID Error, GPU Operator
The Data Center GPU Manager, a toolkit that collects GPU health and performance metrics and can run diagnostic tests. It feeds cluster monitoring systems and detects issues such as thermal or memory faults.
- XID Error
- Related: nvidia-smi, DCGM, ECC (Error Correcting Code)
A numeric code reported by the NVIDIA driver when a GPU encounters a hardware or software fault. Values such as 48, 63, or 79 point to specific failure classes that guide repair or reset decisions.
- ECC (Error Correcting Code)
- Related: XID Error, Burn-In Test, DCGM
Memory protection that detects and corrects certain bit errors in GPU memory. Monitoring corrected and uncorrected counts helps distinguish a degrading module from a transient fault.
- Burn-In Test
- Related: ECC (Error Correcting Code), NCCL, Acceptance Testing
A sustained stress run that exercises GPUs, memory, and network links before a cluster enters production. It exposes marginal hardware and cabling faults that appear only under full load.
- Acceptance Testing
- Related: Burn-In Test, Bisection Bandwidth, NCCL
A structured validation performed after installation to confirm the cluster meets design requirements. It usually covers hardware inventory, link health, collective bandwidth, and storage throughput.
- Slurm
- Related: CPU Affinity, Kubernetes Device Plugin, Checkpoint
An open-source workload manager that allocates nodes and GPUs to jobs and enforces queue policies. It uses GRES or device configuration to grant exclusive or shared accelerator access.
- Kubernetes Device Plugin
- Related: GPU Operator, MIG (Multi-Instance GPU), Time-Slicing
An extension that advertises GPU resources to the Kubernetes scheduler and assigns them to pods. It works with the container toolkit so containers receive only the devices they requested.
- Checkpoint
- Related: GPU Direct Storage (GDS), Parallel File System, Slurm
A saved snapshot of model weights and optimizer state written periodically so training can resume after failure. Fast parallel checkpointing to shared storage reduces lost work on large jobs.
- Parallel File System
- Related: Checkpoint, NFS, GPU Direct Storage (GDS)
A storage system that spreads files across many servers to deliver aggregate throughput beyond one node. AI clusters rely on it to feed training data and absorb checkpoint bursts.
- NFS
- Related: Parallel File System, Checkpoint, RDMA
A network file system protocol for sharing directories across hosts. It is simple and common for home directories but generally lacks the parallel throughput and scaling needed for large training datasets.
- RDMA
- Related: InfiniBand, RoCEv2, GPUDirect RDMA
Remote Direct Memory Access lets one host read or write another host's memory without involving its CPU. It delivers the low latency and high throughput that distributed training communication depends on.
- Multi-Tenancy Isolation
- Related: MIG (Multi-Instance GPU), Role-Based Access Control, Confidential Computing
The practice of separating users, namespaces, and workloads so one tenant cannot access another's data or GPUs. It combines identity controls, network policy, and device-level partitioning.
- Confidential Computing
- Related: Multi-Tenancy Isolation, Secure Boot, Attestation
Hardware-based protection that encrypts data in use so the host operating system and administrators cannot read it. On GPUs it enables trusted execution for sensitive models and datasets.