- CT value
- The product of disinfectant residual concentration in mg/L and contact time in minutes. Required CT rises as water temperature falls and, for free chlorine, as pH rises.
- Breakpoint chlorination
- The chlorine dose at which demand is satisfied and free residual begins to persist. It typically occurs near a 7โ9:1 chlorine-to-ammonia-nitrogen mass ratio.
- Jar test purpose
- A bench test that simulates coagulation, flocculation, and settling at several chemical doses to identify the dose and pH giving the best settled water quality.
- Turbidity rule limits
- Combined filter effluent must be 0.3 NTU or less in at least 95 percent of monthly samples and never above 1 NTU; individual filters must never exceed 1 NTU.
- Langelier Saturation Index
- Calculated as pH minus pHs. A negative index indicates corrosive water, a positive index indicates scale-forming water, and near zero indicates balanced water.
- Chlorine demand
- The difference between the chlorine dose applied and the residual remaining after the contact period. It reflects consumption by ammonia, organics, and other reducing substances.
- Pressure and head
- One psi equals about 2.31 feet of water head. A 100-foot elevation difference therefore produces roughly 43.3 psi of static pressure.
- Distribution residual minimum
- A detectable disinfectant residual must be maintained throughout the distribution system; many states target about 0.2 mg/L free or 0.5 mg/L total chlorine as a minimum.
- Air gap backflow protection
- A physical separation between the potable water outlet and the flood-level rim of a receiving vessel. It provides the highest level of backflow protection.
- RPZ assembly use
- A reduced-pressure-zone assembly protects against both backsiphonage and backpressure. It requires annual testing and is used on high-hazard cross-connections.
- Water hammer cause
- A pressure surge caused by rapid changes in flow velocity, such as fast valve closure or pump trip. Slow valve operation reduces the surge magnitude.
- Flow equation Q=AV
- Flow equals cross-sectional area times velocity. Doubling pipe diameter quadruples area, so flow at the same velocity increases fourfold.
- Sludge age (SRT)
- The mass of solids in the aeration basin divided by the mass of solids leaving the system each day through wasting and effluent.
- Food-to-microorganism ratio
- The daily BOD or COD load entering the aeration basin divided by the mass of mixed liquor solids in the basin. Low ratios indicate long sludge age.
- Sludge volume index
- Settled sludge volume in mL/L after 30 minutes, multiplied by 1000, divided by MLSS in mg/L. Values near 80 to 150 indicate good settling.
- Nitrification oxygen demand
- Oxidizing ammonia to nitrate consumes about 4.6 mg of oxygen per mg of ammonia nitrogen and destroys alkalinity, roughly 7.1 mg/L as CaCO3 per mg/L nitrogen.
- Filamentous bulking
- A condition where filamentous bacteria dominate the mixed liquor, producing a high sludge volume index, poor settling in the clarifier, and solids carryover in the effluent.
- Minimum sewer velocity
- Gravity sewers are typically designed for at least 2 feet per second at design flow to keep solids moving and prevent deposition, with about 10 feet per second as a maximum.
- Manning's equation
- V equals 1.486 divided by n, times hydraulic radius to the two-thirds power, times slope to the one-half power. The constant applies to US customary units.
- Infiltration versus inflow
- Infiltration is groundwater entering through pipe defects and joints. Inflow is stormwater entering through direct connections such as roof drains and storm inlets.
- Hydrogen sulfide corrosion
- H2S forms in septic sewage, oxidizes to sulfuric acid on moist concrete above the waterline, and destroys pipe and manhole walls. Ventilation and liners reduce damage.
- Confined space oxygen range
- Acceptable entry oxygen is 19.5 to 23.5 percent. Below 19.5 percent is oxygen-deficient; above 23.5 percent creates an explosion hazard.
- Chlorine gas exposure limit
- The OSHA permissible exposure limit for chlorine is 1 ppm as a ceiling, and the NIOSH immediately dangerous to life or health value is 10 ppm.
- Hydrogen sulfide IDLH
- The immediately dangerous to life or health concentration for hydrogen sulfide is 100 ppm; the OSHA ceiling is 20 ppm. H2S is heavier than air.
- Methane LEL
- The lower explosive limit of methane in air is 5 percent by volume. Entry into a space above 10 percent of the LEL requires ventilation and controls.
- Lockout tagout rule
- All energy sources must be isolated and verified at zero energy, and each worker applies a personal lock. Only the person who applied a lock may remove it.
- Total Coliform Rule
- No more than 5 percent of samples may be total-coliform-positive per month for systems collecting at least 40 samples; an E. coli positive triggers public notice.
- Stage 2 DBP limits
- Running annual averages may not exceed 80 micrograms per liter for total trihalomethanes or 60 micrograms per liter for five haloacetic acids at each monitoring location.
- Lead and Copper Rule
- The action level is 0.015 mg/L for lead and 1.3 mg/L for copper, based on the 90th percentile of first-draw samples from high-risk sites.
- Arsenic MCL
- The maximum contaminant level for arsenic is 0.010 mg/L, or 10 micrograms per liter. Systems exceeding it must install treatment or change sources.
- NPDES permit role
- A Clean Water Act permit that sets effluent limits, monitoring, and reporting requirements for point-source discharges to surface waters. Discharging without one is prohibited.
- Chemical feed formula
- Pounds per day of chemical equals flow in million gallons per day, times dose in mg/L, times 8.34. This converts concentration and volume into mass per day.
- Pump brake horsepower
- Brake horsepower equals flow in gpm times head in feet times specific gravity, divided by 3960 times pump efficiency. It estimates power delivered to the pump shaft.
- Pump cavitation cause
- Cavitation occurs when available net positive suction head falls below required net positive suction head, producing vapor bubbles, noise, vibration, and reduced flow.