- Jar test
- Bench-scale test that mixes coagulant at several doses and pH values to find the dose producing the best turbidity removal and settleability.
- CT
- Product of disinfectant residual concentration in mg/L and contact time in minutes; required CT increases as pH rises and temperature falls.
- Chlorine demand
- Difference between the chlorine dose applied and the residual remaining after a specified contact time; it reflects oxidant consumed by water constituents.
- Surface overflow rate
- Clarifier flow divided by its surface area, expressed as gpm/ft² or m³/m²·d; it equals the settling velocity of the slowest particle captured.
- Langelier Saturation Index
- An index calculated from pH, temperature, calcium hardness, alkalinity, and total dissolved solids; negative values indicate corrosive water and positive values scaling water.
- Filter backwash
- Reverse flow through a filter that expands the media 20–30% and flushes captured solids to waste; the rate is typically 15–20 gpm/ft².
- Turbidity limits
- Conventional and direct filtration combined filter effluent must be ≤0.3 NTU in at least 95% of monthly samples and never exceed 1 NTU.
- Lime-soda softening
- Process that adds lime to raise pH and precipitate calcium carbonate, and more lime plus soda ash to remove magnesium as magnesium hydroxide.
- Minimum distribution pressure
- Distribution systems must maintain at least 20 psi at all points under normal and emergency conditions; typical operating pressures are 40–80 psi.
- Maximum chlorine residual
- The maximum residual disinfectant level for free chlorine is 4.0 mg/L, measured as a running annual average at each monitoring location.
- Air gap
- A physical separation between a potable water outlet and the flood level of a receiving vessel; it provides the highest level of backflow protection.
- RPZ backflow preventer
- Reduced pressure zone assembly with two check valves and a relief valve; used for high-hazard cross connections where backpressure or backsiphonage is possible.
- New main disinfection
- AWWA C651 requires a new water main to be chlorinated at 50 mg/L for 24 hours, flushed, and left with at least 25 mg/L residual.
- Hazen-Williams C factor
- Empirical roughness coefficient in the Hazen-Williams head-loss formula; lower values mean rougher pipe and greater friction loss, as with tuberculated old mains.
- Water hammer
- Pressure surge caused by a rapid change in flow velocity, such as fast valve closure or pump trip; it can rupture pipes and damage fittings.
- Distribution flushing velocity
- Flushing should achieve at least 2.5–3 ft/s in the main to scour and carry away sediment and stale water.
- Food-to-microorganism ratio
- F/M equals BOD mass applied per day divided by MLVSS mass in the aeration tank; conventional activated sludge operates near 0.2–0.5 day⁻¹.
- Mean cell residence time
- MCRT or sludge age equals solids mass in the aeration system divided by solids leaving per day in waste sludge and effluent.
- Sludge volume index
- SVI is the settled sludge volume in mL after 30 minutes per gram of MLSS; 80–150 mL/g indicates good settling and above 200 indicates bulking.
- Mixed liquor suspended solids
- MLSS is the concentration of suspended solids in the aeration tank, typically 2,000–4,000 mg/L in conventional activated sludge.
- Secondary clarifier solids loading
- Solids loading rate equals solids applied per day divided by clarifier area; typical design values are 15–30 lb/day/ft².
- Nitrification alkalinity demand
- Oxidizing ammonia to nitrate consumes about 7.14 mg of alkalinity as CaCO3 per mg of ammonia nitrogen and requires dissolved oxygen above 2 mg/L.
- Mesophilic anaerobic digestion
- Digestion at about 35°C (95°F) with a solids retention time commonly 15–30 days; it reduces volatile solids and produces methane.
- Facultative stabilization pond
- Pond with an aerobic surface zone and anaerobic bottom; algae supply oxygen to bacteria, and bacteria release nutrients and carbon dioxide to algae.
- Manning equation
- Open-channel flow formula Q = (1.486/n) A R^(2/3) S^(1/2); n is roughness, A is cross-sectional area, R is hydraulic radius, and S is slope.
- Self-cleaning sewer velocity
- A minimum velocity of about 2 ft/s at design flow keeps solids moving and prevents deposition in sanitary sewers.
- Infiltration
- Groundwater that enters a sewer through defective pipes, joints, or manholes; it raises dry-weather flow and treatment costs.
- Inflow
- Direct storm water or surface water that enters a sewer through improper connections such as roof drains, yard drains, or manhole covers.
- Trench protective system
- OSHA requires shoring, shielding, sloping, or benching for excavations 5 feet or deeper where there is no stable rock.
- Confined space oxygen level
- Acceptable entry oxygen is 19.5–23.5%; the atmosphere must be tested before entry and a permit is required for permit spaces.
- Minimum 8-inch sewer slope
- Typical minimum grade is 0.4% (0.004 ft/ft) for 8-inch pipe and 0.22% for 12-inch pipe to maintain self-cleansing velocity.
- Lift station check valve
- Valve on each pump discharge that closes when the pump stops to prevent backflow and keep the wet well from being refilled.