Ruptured Hose with Crews in the Platform

NFPA 1002 Driver/Operator - Aerial · Put your knowledge to work in context.

All case studies

Ruptured Hose with Crews in the Platform

At 14:40 your 75-ft elevating platform is at 60 ft with two firefighters in the bucket, 520 lb total, preparing to take a sixth-floor window. The operator hears a sharp pop at the turntable and sees a mist of hydraulic fluid. The platform stops responding: no boom, no rotation, no bucket leveling. The ground master panel has power but no function operates. The intercom is dead. The boom has drifted down about 2 ft in six minutes and is still creeping. The bucket is 8 ft out from the wall and just below the parapet. Outside temperature is 28 F, wind 12 mph, and the second aerial is 12 minutes out. The IC asks whether a firefighter should climb the ladder to reach them.

1. Give your prioritized actions for the first five minutes and the reasoning behind each.

Read the worked answer

Order matters because several actions protect people who are not yet in danger.

  1. Stop and secure: confirm both platform and ground controls are in neutral and the emergency stop is engaged so nothing moves unexpectedly if power returns.
  2. Exclusion zone: clear the area under the boom and platform to at least the working length of the boom. The dominant risk in the first minutes is a sudden descent onto people on the ground, not the occupants, who are restrained in a bucket.
  3. Occupants: confirm harnesses and lanyards are anchored to the manufacturer's anchor points, tell them to stay in the bucket and stay off the controls, and keep voice contact by radio or a relay since the intercom is out.
  4. Diagnose before you improvise: check PTO engagement, pump pressure, master switch, and any circuit breaker or fuse at the turntable. A no-function condition with panel power often means a control circuit or interlock fault, and ground controls may still work if selected correctly.
  5. Escalate: confirm the second aerial, notify the IC and safety officer, and start the manufacturer's emergency lowering procedure per the manual, hand pump or metering valve, only after the drop zone is clear. Do not send anyone up the boom or the ladder to reach a platform bucket.

2. The boom keeps drifting down. What does that tell you and how does it change the plan?

Read the worked answer

Drift with unresponsive controls means a load-holding path is leaking: a ruptured hose or fitting on the lift circuit, a failed holding valve or check valve, or an internal leak past a cylinder seal. The pop and the mist point to a hose or fitting, which means system pressure is being dumped rather than held.

The practical consequences:

  • Drift can accelerate. As fluid escapes and the valve seat or hose damage worsens, the rate of descent is not predictable. Keep everyone out from under, and do not let well-meaning crews stand beneath the bucket to catch it.
  • Controlled lowering may still be possible through the emergency system if the descent circuit itself is intact; try it, but be ready for it not to hold.
  • If drift is slow and the bucket is near the wall, the better outcome may be to let it land or to bring it against the building face to arrest the descent, provided that can be done without shock loading and the wall can take the contact. That decision belongs to the operator with the manual in hand, not to the IC.
  • If the drift accelerates, clear the zone, let it come down, and treat it as a recovery rather than a rescue.

3. After everyone is on the ground, what happens to the apparatus and the paperwork?

Read the worked answer

The aerial is out of service immediately. It gets a red tag or out-of-service placard, is removed from response, and does not return to service until the failed hose or fitting is replaced, the system is flushed and filtered, pressure tested, and function tested through the full range of motion by a qualified technician. Because the event involved a loss of load holding and a possible shock load, expect an inspection of the structural and hydraulic components, including nondestructive examination where the manufacturer or your inspection standard calls for it, before any lifting of personnel.

The documentation is part of the repair, not an afterthought: a work order describing the failure mode and the repair; the daily and post-incident inspection entries; a near-miss or injury report if anyone was exposed; notification to the chief and the safety officer; and confirmation that the aerial's inspection and load test records are current before it goes back in service. If the descent was arrested against the building, note that contact and have the affected sections inspected. Notify dispatch of the coverage gap and arrange a move-up.