- NFPA 1911
- Standard governing inspection, maintenance, testing, and retirement of in-service fire apparatus. It sets minimum daily, weekly, annual, and periodic check requirements and the records that must be kept.
- Annual pump service test
- Run 20 minutes at rated capacity, 10 minutes at 70 percent capacity with 150 psi net, and 10 minutes at 50 percent capacity with 250 psi net, recording all readings.
- Steering axle tire tread
- Tires on the steering axle of fire apparatus must be replaced when tread depth falls below 4/32 inch; tires on all other axles are replaced below 2/32 inch.
- Aerial load test interval
- An aerial device receives an annual inspection and test, plus a structural load test at least every five years. All results are documented and retained for the apparatus service life.
- Out-of-service documentation
- A defect affecting brakes, steering, tires, pump, or aerial integrity requires the apparatus be tagged out of service and the condition recorded on a work order until repaired and signed off.
- Total stopping distance
- The sum of perception distance, reaction distance, brake-lag distance, and effective braking distance. It grows with speed, and braking distance grows with the square of speed.
- Apparatus following distance rule
- Allow one second per ten feet of apparatus length plus one second, and add another second whenever speed exceeds 40 mph.
- Engine brake on slippery roads
- Exhaust and compression brakes are switched off on wet, icy, or snow-covered pavement because drive-wheel lockup can cause a sudden loss of control or jackknife.
- Tire blowout response
- Grip the steering wheel firmly, hold the apparatus straight, release the accelerator, and avoid hard braking until speed is reduced and control is regained.
- Railroad crossing procedure
- Stop the apparatus when required, open the window, look and listen in both directions, and cross only when clear. Never stop or shift on the tracks.
- Collapse zone distance
- Keep all personnel and apparatus at least a distance equal to the height of the involved building, and increase that zone for unsupported walls or heavy contents.
- Ground ladder angle
- Set the ladder base one foot from the wall for every four feet of working height, producing roughly a 75-degree angle for safe climbing and load capacity.
- Outrigger placement
- Fully extend outriggers on firm, level ground. Never place them over basements, vaults, septic tanks, or manhole covers where the ground can fail.
- Overhead line clearance
- Keep apparatus, aerials, ladders, and water streams at least 10 feet from energized overhead lines, increasing the distance as voltage increases, and treat all downed lines as energized.
- Pump discharge pressure formula
- PDP equals nozzle pressure plus total friction loss plus elevation change plus appliance loss. Add 0.5 psi per foot of rise and subtract 0.5 psi per foot of drop.
- Friction loss formula
- FL equals C times Q squared times L, where C is the hose coefficient, Q is flow in hundreds of gpm, and L is hose length in hundreds of feet.
- Hose friction loss coefficients
- With flow in hundreds of gpm, C values are 15.5 for 1 3/4-inch hose, 2 for 2 1/2-inch, 0.8 for 3-inch, 0.2 for 4-inch, and 0.08 for 5-inch.
- Rated pump capacity test
- A fire pump must deliver 100 percent of rated capacity at 150 psi, 70 percent at 200 psi, and 50 percent at 250 psi during the rated capacity test.
- Cavitation causes
- Insufficient water supply, excessive lift, a clogged strainer, or an air leak in the intake produces a rattling pump, fluctuating gauge readings, and lost capacity.
- Maximum theoretical lift
- Atmospheric pressure limits drafting lift to about 33.9 feet at sea level. Practical lift is 20 to 25 feet and decreases with altitude, hose wear, and intake restrictions.
- Forward lay
- The engine stops at the hydrant, lays supply hose from the hydrant to the fire scene, and is then supplied by that hydrant while pumping to the fire.
- Reverse lay
- The engine stops at the fire scene and a supply line is laid from the scene back to the hydrant, where another pumper takes the hydrant and pumps forward.
- Drafting strainer depth
- Keep the strainer at least 24 inches below the water surface and 12 to 24 inches off the bottom, and use a floating strainer in shallow or muddy water.
- Water shuttle flow formula
- Flow in gpm equals tank capacity in gallons multiplied by the number of tankers, divided by the round-trip cycle time in minutes.
- Aerial load chart
- The manufacturer's plate lists rated tip load and total load. Capacity decreases as the ladder extends and as the angle is lowered toward horizontal.
- Aerial electrical clearance
- Keep the aerial ladder, platform, and water stream at least 10 feet from energized lines, and increase that distance substantially for higher transmission voltages.
- Master stream nozzle pressures
- Master stream smooth-bore nozzles are designed for 80 psi nozzle pressure and fog master stream nozzles for 100 psi, per the nozzle standard.
- Aerial emergency lowering
- Auxiliary power or a manual bleed-down procedure retracts the aerial if the main hydraulic or electrical system fails. Operators must know and drill this procedure.
- Due regard
- Emergency vehicle operators may use warning lights and siren to obtain legal privileges but are never relieved of the duty to drive with due regard for others' safety.
- Move Over law
- Drivers approaching a stopped emergency or highway vehicle displaying warning lights must slow down and, when safe, change lanes to leave a buffer.
- Two-in/two-out
- At least two firefighters must be inside the structure and two outside, ready to rescue, before interior firefighting begins in an immediately dangerous to life and health atmosphere.
- High-visibility apparel
- Personnel working on or near a roadway must wear ANSI/ISEA 107 compliant high-visibility vests or garments so approaching traffic can see them.