NFPA Firefighter II · Keep the key ideas within reach.

Quick reference

General: Safety, Health and Wellness, Incident Management

  • 29 CFR 1910.134 two-in/two-out: when two members enter an IDLH atmosphere for interior structural firefighting, two trained and equipped members must remain outside and be capable of rescuing them.

  • NFPA 1500 requires an incident management system at every incident; every member works within one command structure with a known supervisor and assignment.

  • "Mayday, Mayday, Mayday" is transmitted when a member is lost, trapped, out of air, or unconscious; all other radio traffic stops until the IC acknowledges.

  • LUNAR content for a Mayday message: Location, Unit, Name, Air remaining, Resources needed.

  • A personnel accountability report (PAR) confirms the status of every assigned member; it is taken at benchmarks, after an evacuation signal, and whenever the IC orders it.

  • NFPA 1584 rehabilitation: a member whose heart rate remains above 100 beats per minute after 20 minutes of rehab is not returned to fireground duty.

  • The SCBA low-air alarm activates at roughly 33 percent of rated capacity; NFPA 1404 air management calls for exiting before the alarm sounds, with a 50 percent turn-around point as a practical margin.

  • Emergency evacuation signal: three cycles of three seconds on and three seconds off; members exit the structure and report to their supervisors for a PAR.

Quick reference

Fire Department Communications

  • NFPA 1221 benchmarks: 95 percent of emergency calls answered within 15 seconds; 90 percent of alarms processed within 60 seconds and 99 percent within 90 seconds.

  • NIMS requires plain language (clear text) on the fireground; ten-codes and agency-specific signals are not used on multijurisdiction incidents.

  • Radio procedure: press the push-to-talk button, pause about one second, speak at a normal rate across the microphone, release, and listen.

  • CAN report = Conditions, Actions, Needs; it is the standard format for a unit progress report to the incident commander.

  • "Emergency traffic" clears the channel for a priority message; a Mayday outranks emergency traffic.

  • Benchmark reports: arrival/on scene, water on the fire, primary search complete (all clear or victims located), fire knocked down, PAR, and under control.

  • Status changes transmitted to dispatch: responding, on scene, available or in service, and returning.

  • Radios used in flammable or IDLH atmospheres must be intrinsically safe; NFPA 1802 covers two-way portable RF voice communication devices.

  • Simplex channels allow one transmission at a time on a single frequency; duplex systems use a repeater with separate transmit and receive frequencies.

Quick reference

Fireground Operations

  • NFA fire flow formula: needed flow in gpm = (length x width x number of stories involved) / 3; a 20-foot by 30-foot single-story building requires 200 gpm.

  • If the required fire flow exceeds the available water supply, the incident commander changes to a defensive strategy.

  • A 1 3/4-inch handline with a 15/16-inch smooth-bore tip flows about 185 gpm at 50 psi nozzle pressure; 2 1/2-inch lines are used when higher flows or master streams are needed.

  • Nozzle pressures: smooth bore 50 psi, combination fog 100 psi, unless the manufacturer specifies otherwise.

  • Reading smoke uses four characteristics: volume, velocity, density, and color; high-velocity, dense, dark smoke signals high heat and likely flashover.

  • Elevation loss is about 0.434 psi per foot, roughly 5 psi per story, and is added to nozzle pressure when pumping to upper floors.

  • Standpipe operations: pump into the FDC at the system's designed pressure, do not exceed the system working pressure, and check upper-floor outlets for pressure-reducing valves.

  • Overhaul opens concealed spaces and uses a thermal imager to find hidden fire; the area of origin and evidence are left undisturbed for the investigator.

  • Ventilation is coordinated with fire attack; venting before a charged line is in place can pull fire toward the opening and endanger occupants and crews.

Quick reference

Rescue Operations

  • Rescue priorities: life safety first, then incident stabilization, then property conservation.

  • Vehicle extrication order: stabilize the vehicle on all four sides, manage the glass, then disentangle the patient.

  • Cribbing stacks are limited to twice the width of the base (2:1 rule) to prevent toppling under load.

  • Permit-required confined space entry requires oxygen between 19.5 and 23.5 percent, flammable atmosphere below 10 percent LEL, and toxic gases within exposure limits; oxygen is tested first.

  • Water rescue sequence: reach, throw, row, go; water entry is a last resort for trained and equipped rescuers.

  • Structural collapse: identify void spaces where victims can survive; entry into an unshored collapse is prohibited without training and equipment.

  • NFPA 1983 life safety rope is dedicated to rescue, inspected after each use, and never used as a utility rope.

  • Ground ladder placement: 75-degree angle (1:4), tip three to five rungs above the roof for roof access, tip at the sill for window rescue.

  • The RIC/FAST stages outside the hazard zone with a charged hoseline, hand tools, thermal imager, rope, and ladders, ready to deploy on a Mayday.

Quick reference

Fire Prevention and Preparedness

  • Fire cause classifications: accidental, natural, incendiary, and undetermined; firefighters report observations and preserve evidence but do not make the official determination.

  • A V-pattern indicates fire spread upward and outward from its base; the point of the V locates the area of origin.

  • Extinguisher classes: A ordinary combustibles, B flammable liquids, C energized electrical equipment, D combustible metals, K cooking oils and fats.

  • NFPA 10 travel distances: Class A no more than 75 feet, Class B no more than 50 feet, Class D no more than 75 feet.

  • Preincident plan content: occupancy and construction, access and apparatus placement, water supply, utilities, special hazards, built-in protection, and emergency contacts.

  • NFPA 291 hydrant color code: blue 1,500 gpm or more, green 1,000 to 1,499 gpm, orange 500 to 999 gpm, red less than 500 gpm.

  • Smoke alarms are tested monthly and replaced every 10 years; ionization units respond faster to flaming fires and photoelectric units to smoldering fires.

  • Firefighter II may perform company-level inspections and preincident surveys; code violations and occupancy changes are reported to the authority having jurisdiction.