Quick reference

Shipboard fire theory: fire triangle/tetrahedron, ignition sources, and fire chemistry

  • Fire triangle: fuel + oxygen + heat. Fire tetrahedron adds the chemical chain reaction; removal of any side extinguishes fire.

  • Flammable range: the proportion of vapour in air between the lower explosive limit (LEL) and upper explosive limit (UEL). Below LEL the mixture is too lean; above UEL it is too rich.

  • Flashpoint: the lowest temperature at which a liquid gives off sufficient vapour to form an ignitable mixture. A liquid with a flashpoint below 60°C is classified as flammable.

  • Ignition sources on board include open flames, hot surfaces, electrical arcing, static electricity, spontaneous combustion, and hot work sparks.

  • Spontaneous heating occurs when materials such as oily rags, coal, or fishmeal oxidise without adequate ventilation, generating heat faster than it can dissipate.

  • Oxygen concentration in normal air is about 21% by volume; combustion becomes sluggish below 15% and cannot be sustained below about 8%.

  • Heat transfer by conduction, convection, and radiation determines fire spread; radiation is the dominant mode across open spaces.

  • Vapour density: most hydrocarbon vapours are heavier than air and accumulate in low spaces such as bilges and holds.

Quick reference

Fire hazards and prevention: flammable liquids, gases, electrical hazards, hot work, and housekeeping

  • Flammable liquid spills must be contained and cleaned immediately; use non-sparking tools and avoid water on fuel fires.

  • Gas cylinders must be stored upright, secured, away from heat sources, and separated from oxidisers; acetylene and oxygen must never be stored together.

  • Electrical hazards: overloaded circuits, damaged insulation, and loose connections cause arcing; use certified flameproof equipment in hazardous zones.

  • Hot work permit requires gas-free certificate, fire watch, removal of combustibles within 10 m, and availability of firefighting equipment.

  • Housekeeping: keep passageways and escape routes clear, store oily rags in covered metal containers, and remove accumulated grease from galley ducts.

  • Bulkhead and deck penetrations must be sealed to maintain fire integrity; self-closing fire doors must not be wedged open.

  • Static electricity can be generated by fluid flow; bonding and grounding are required during fuel transfer operations.

  • Smoking is prohibited except in designated areas; ashtrays must not be emptied into waste bins.

Quick reference

Fire detection and alarm systems, fixed installations, and emergency communications

  • Heat detectors respond when temperature exceeds a set threshold or rises at a predetermined rate; they are slower than smoke detectors.

  • Smoke detectors: ionisation type responds to invisible combustion particles; photoelectric type responds to visible smoke. Both are suited to different fire types.

  • Flame detectors sense ultraviolet or infrared radiation from flames and respond within seconds; used in high-risk spaces such as machinery rooms.

  • Fixed CO2 system: smothers fire by reducing oxygen; must not be used in occupied spaces without evacuation and headcount.

  • Fixed foam system: blankets flammable liquid fires; used in machinery spaces and cargo tanks. Foam concentrate must be compatible with the fuel.

  • Water sprinkler system: automatic activation by heat; provides cooling and wetting. Must not be used on electrical fires unless de-energised.

  • Emergency communications: internal telephone, sound-powered telephone, and portable radios; use clear, concise messages and repeat back.

  • General emergency alarm: seven or more short blasts followed by one long blast on the ship's whistle and internal alarm.

Quick reference

Firefighting equipment: extinguisher types, hoses, nozzles, couplings, and breathing apparatus

  • Water extinguisher (Class A): cools burning material; never use on electrical or flammable liquid fires.

  • Foam extinguisher (Class B): forms a blanket to exclude oxygen; use on flammable liquids and gases.

  • CO2 extinguisher (Class B and electrical): displaces oxygen and leaves no residue; do not use in confined spaces without ventilation.

  • Dry powder extinguisher (ABC): interrupts chemical chain reaction; effective on multiple fire classes but can cause cleanup problems.

  • Fire hose: standard diameters 45 mm and 65 mm; pressure tested periodically. Nozzles: jet for reach, spray for cooling and protection.

  • Storz coupling: symmetrical, quick-connect; ensure lugs engage fully. John Morris coupling: uses a locking ring; check for damage before use.

  • SCBA: self-contained breathing apparatus provides breathable air from a cylinder; check pressure gauge (minimum 80% before use) and whistle alarm.

  • Firefighter's outfit: helmet, fire-resistant gloves, boots, and proximity suit for approach; ensure all skin is covered.

Quick reference

Firefighting tactics and procedures: containment, boundary cooling, ventilation control, and extinguishing methods

  • Boundary cooling: apply water spray to adjacent bulkheads and decks to prevent fire spread; monitor temperature with thermal imaging camera.

  • Ventilation control: close all openings to limit oxygen supply; use smoke extraction only after fire is controlled.

  • Containment: close fire doors and shutters; isolate fuel sources by shutting off valves and pumps.

  • Extinguishing methods: cooling (water), smothering (foam, CO2), starvation (removing fuel), and chemical inhibition (dry powder).

  • Indirect attack: use fog or spray from a protected position to cool hot gases and reduce flashover risk before entry.

  • Direct attack: apply extinguishing agent directly onto the burning material once located and safe to approach.

  • Team entry: always enter in pairs with a charged hose line; maintain communication and monitor air supply.

  • Post-fire: continue boundary cooling, ventilate to remove smoke, and check for re-ignition before declaring fire out.

Quick reference

Classification of fires and selection of appropriate extinguishing media

  • Class A: solid combustibles (wood, paper, textiles). Extinguish with water, foam, or dry powder.

  • Class B: flammable liquids (oil, petrol, paint). Extinguish with foam, CO2, or dry powder; never use water jet.

  • Class C: flammable gases (LPG, methane). Extinguish with dry powder or CO2; shut off gas supply first if possible.

  • Class D: combustible metals (magnesium, sodium). Extinguish with special dry powder; never use water, foam, or CO2.

  • Class E (electrical): fires involving live electrical equipment. Extinguish with CO2 or dry powder; de-energise before using water.

  • Class F (cooking oils): fires involving cooking fats. Extinguish with wet chemical extinguisher; never use water.

  • Selection rule: match the extinguishing agent to the fire class; using the wrong agent can spread the fire or cause explosion.

  • Water must never be used on live electrical fires or on burning metals such as sodium.

Quick reference

Shipboard fire organization: muster stations, fire teams, command structure, and drills

  • Muster station: designated safe assembly area; all crew must report there on hearing the general emergency alarm.

  • Fire team organization: typically includes attack team, backup team, boundary cooling team, and ventilation control team.

  • Command structure: Master has overall command; On-Scene Leader (usually Chief Officer or Chief Engineer) directs firefighting operations.

  • Communication: use standard phrases; report status regularly; maintain radio discipline.

  • Drills: must be conducted at regular intervals; include scenarios such as machinery space fire and accommodation fire.

  • Muster list: posted at strategic locations; shows each crew member's duty and station.

  • Headcount: must be taken at muster station to account for all personnel; report missing persons immediately.

  • Fire control plan: provides ship layout and firefighting equipment locations; must be available at bridge and outside accommodation.

Quick reference

Personal safety: firefighter PPE, SCBA use, entry control, and casualty rescue

  • PPE: fire-resistant clothing, helmet, gloves, boots, and eye protection. Ensure all skin is covered to prevent burns.

  • SCBA pre-use checks: cylinder pressure (minimum 80%), face mask seal, harness, and whistle alarm.

  • Entry control: establish a control point; record name, time of entry, and air supply duration; maintain communication.

  • Air supply duration: typically 30 minutes; plan exit with reserve. Use buddy system and stay in contact.

  • Casualty rescue: remove casualty to safe area; use drag or carry techniques; do not remove SCBA until safe.

  • Decontamination: after firefighting, clean PPE and equipment; report any damage or exposure.

  • Heat stress: monitor firefighters for fatigue; rotate teams and ensure hydration.

  • Emergency escape: know alternate routes; if SCBA fails, use escape hood or follow hose line out.

Quick reference

Fire investigation, reporting, and post-fire safety precautions

  • Preserve evidence: do not disturb the fire scene until investigation is complete; photograph and document.

  • Fire report: include time, location, cause (if known), extinguishing methods used, and damage assessment.

  • Investigation: determine origin and cause; interview witnesses; check for electrical faults, hot work, or arson.

  • Post-fire safety: check for structural damage, toxic gases, and re-ignition; ventilate spaces before entry.

  • Reporting to authorities: follow flag state and port state requirements; submit reports within required timeframes.

  • Insurance and class: notify relevant parties; keep records for claims and inspections.

  • Lessons learned: review fire drills and procedures; update muster list and training as needed.

  • Environmental: contain firefighting water runoff to prevent pollution; use absorbents and report spills.