NIMASA STCW FPFF: Fire Detection and Alarm Systems, Fixed Installations and Emergency Communications

NIMASA STCW FPFF · Work through your exam, one topic at a time.

All guide sections

Fire Detection and Alarm Systems, Fixed Installations and Emergency Communications

Detection, fixed installations and communications are examined as one chain: the alarm must be raised, the right system released, and the right people told.

Detection

  • Optical smoke detectors respond to visible smoke; ionisation units to sub-micron particles. Neither belongs in a galley or bathroom - use heat detectors there.
  • Heat detectors are fixed-temperature (typically 57–74 °C) or rate-of-rise; flame detectors use UV or IR and react within seconds in machinery spaces.
  • Manual call points sit at exits, and the alarm must repeat on the bridge and in the engine control room.

Fixed installations

  • CO2 total flooding for machinery spaces: pre-discharge alarm, about a 20-second delay, evacuation and headcount, all openings sealed, and no re-entry until the space is ventilated and tested.
  • Foam: deck foam on tankers, high-expansion in machinery spaces, low-expansion for spill blankets.
  • Water: sprinklers in accommodation, drenchers on boundaries, water mist for machinery. A fire control plan and an international shore connection must be available.

Emergency communications

  • General emergency alarm: seven short blasts and one long blast on the whistle and alarm bells. Abandon ship is a verbal order supported by more than six short blasts and one long blast.
  • Internal: PA, sound-powered telephone, UHF portables, talkback. External: VHF Ch 16/DSC, EPIRB, 9 GHz SART, Inmarsat, IMO Standard Marine Communication Phrases.

Worked example

A smoke detector operates in a corridor at 03:00. The bridge acknowledges, notes the zone, sends a runner with a portable radio and a BA team with a charged hose. Silencing the alarm and logging 'false alarm' without an investigation is the error.

Traps

  • Confusing the general emergency alarm with the abandon-ship signal.
  • Dismissing a detector that keeps operating as 'just faulty'.
  • Re-entering a CO2-flooded space because the fire looks out.