Initiating Device

A system component such as a smoke detector, heat detector, manual pull station, or waterflow switch that signals the fire alarm control unit that a fire or other emergency condition exists.

Related: Initiating Device Circuit, Notification Appliance
Notification Appliance

An audible or visible device such as a horn, speaker, strobe, or chime that alerts occupants. These devices are connected to notification appliance circuits and are controlled by the fire alarm control unit.

Related: Notification Appliance Circuit, Audible/Visible Signaling
Initiating Device Circuit

The wiring path, also called an input circuit or zone, that connects automatic and manual initiating devices to the control unit. It may be conventional or addressable and is supervised for integrity.

Related: Initiating Device, Supervision, Addressable System
Notification Appliance Circuit

The output circuit that supplies power to notification appliances. It is typically supervised for open and short conditions and may be Class A or Class B depending on wiring arrangement.

Related: Notification Appliance, Supervision, Class A Circuit
Addressable System

A system in which each initiating or output device has a unique address, allowing the control unit to identify the specific device in alarm or trouble rather than only the circuit or zone.

Related: Address, Initiating Device Circuit, Intelligent Detector
Conventional System

A system where devices are grouped on circuits or zones and the control unit reports an alarm by zone rather than by individual device. Common in smaller or older installations.

Related: Zone, Initiating Device Circuit
Address

The unique numeric identifier assigned to a device on an addressable system. Addresses let the control unit report device-specific alarm and trouble conditions to the operator and in system records.

Related: Addressable System, Intelligent Detector
Zone

A defined area or grouping of devices reported as a single unit by the control unit. Zones may correspond to building areas, floors, or specific hazards, and are used for alarm annunciation.

Related: Conventional System, Annunciator
Supervision

Continuous monitoring of circuit wiring and system components for abnormal conditions such as opens, shorts, or grounds. Supervised circuits cause a trouble signal when integrity is compromised.

Related: Trouble Signal, Class A Circuit, Class B Circuit
Class A Circuit

A circuit in which the wiring leaves the control unit and returns on a separate path, so a single open does not prevent operation of devices beyond the break. It provides a higher level of reliability.

Related: Class B Circuit, Supervision
Class B Circuit

A circuit where the wiring runs out from the control unit and terminates at the last device. A single open fault disables devices beyond the break, and the fault is reported as a trouble.

Related: Class A Circuit, Supervision
Trouble Signal

An audible and visual indication at the control unit that a fault exists, such as a circuit open, ground fault, power loss, or device failure. It is distinct from an alarm signal.

Related: Supervision, Ground Fault, Alarm Signal
Alarm Signal

The signal produced by the system when an initiating device operates, indicating a fire or emergency condition. It activates notification appliances and is annunciated at the control unit.

Related: Trouble Signal, Notification Appliance
Ground Fault

An unintended connection between a system conductor and earth ground. Ground faults can disrupt operation and are typically detected and reported as a trouble condition by the control unit.

Related: Trouble Signal, Supervision
Smoke Detector

An automatic initiating device that senses smoke particles using ionization or photoelectric technology. It responds to products of combustion and signals the control unit when threshold conditions are met.

Related: Photoelectric Detector, Ionization Detector, Initiating Device
Photoelectric Detector

A smoke detector that uses a light source and photosensor to detect light scattered by smoke particles. It is generally more responsive to visible smoke from smoldering fires.

Related: Smoke Detector, Ionization Detector
Ionization Detector

A smoke detector that uses a small radioactive source to ionize air in a chamber. Smoke entering the chamber changes the current, triggering an alarm. It often responds well to flaming fires.

Related: Smoke Detector, Photoelectric Detector
Heat Detector

An automatic device that responds to temperature rise, either fixed temperature or rate-of-rise, rather than smoke. It is used where smoke detection is unsuitable or as supplementary protection.

Related: Rate-of-Rise Detector, Fixed-Temperature Detector, Initiating Device
Rate-of-Rise Detector

A heat detector that operates when the temperature increases faster than a predetermined rate. It can respond quickly to rapidly developing fires without waiting for a fixed temperature threshold.

Related: Heat Detector, Fixed-Temperature Detector
Fixed-Temperature Detector

A heat detector that operates when the sensed temperature reaches a predetermined set point. It is often combined with rate-of-rise sensing in a single device.

Related: Heat Detector, Rate-of-Rise Detector
Manual Pull Station

A manually operated initiating device that lets a person activate the fire alarm by pulling a handle or lever. It is typically installed along exit paths and near exits.

Related: Initiating Device, Alarm Signal
Waterflow Switch

A device on a sprinkler system that detects sustained water flow and sends an alarm signal to the fire alarm control unit. It is usually set with a delay to avoid false alarms from surges.

Related: Initiating Device, Supervisory Signal
Supervisory Signal

A signal indicating an off-normal condition in a suppression system or other protected equipment, such as a closed valve or low pressure. It is distinct from alarm and trouble signals.

Related: Trouble Signal, Waterflow Switch
Fire Alarm Control Unit

The central panel that receives signals from initiating devices, processes them, and controls notification appliances. It also monitors circuit integrity and annunciates alarm, supervisory, and trouble conditions.

Related: Initiating Device Circuit, Notification Appliance Circuit, Annunciator
Annunciator

A remote or local display panel that indicates the status of zones or devices, such as alarm, trouble, or supervisory conditions. It helps responders locate the area of an event.

Related: Zone, Fire Alarm Control Unit
Primary Power Supply

The main source of electrical power for the fire alarm system, typically commercial AC power. Loss of primary power is monitored and reported as a trouble condition.

Related: Secondary Power Supply, Trouble Signal
Secondary Power Supply

A backup power source, such as batteries or a generator, that keeps the system operational when primary power fails. It is sized to support the system for a specified duration.

Related: Primary Power Supply, Battery Calculation
Battery Calculation

The process of determining the battery capacity needed to support the fire alarm system during a specified standby period plus alarm time, accounting for loads and aging.

Related: Secondary Power Supply, Primary Power Supply
Audible/Visible Signaling

The use of sound and light to alert occupants. Audible signals must meet required sound levels, and visible signals such as strobes are required where hearing may be impaired or noise is high.

Related: Notification Appliance, Notification Appliance Circuit
Intelligent Detector

An addressable detector that can report analog values and status to the control unit, allowing sensitivity monitoring and drift compensation. It supports more precise alarm reporting than conventional devices.

Related: Addressable System, Address
Duct Detector

A smoke detector installed in an HVAC duct to detect smoke being circulated through the building. It typically shuts down the air handler and sends an alarm signal to the control unit.

Related: Smoke Detector, Initiating Device
Interface Module

An addressable device that connects conventional initiating devices or control functions to an addressable system. It allows non-addressable equipment to be monitored or controlled by the panel.

Related: Addressable System, Relay Module
Relay Module

An addressable output device that provides dry contacts to control or switch other equipment, such as door holders, dampers, or fans, in response to system conditions.

Related: Interface Module, Addressable System
Ground Fault Detection

The system function that senses unintended connections between conductors and ground. Detection helps maintain circuit integrity and is reported as a trouble condition for service attention.

Related: Ground Fault, Trouble Signal
Alarm Verification

A feature that delays alarm processing briefly to confirm a detector signal, reducing false alarms from transient conditions. It must be used in accordance with applicable installation standards.

Related: Smoke Detector, Alarm Signal
Pre-Signal

A system feature that causes an initial alarm at the control unit or a designated location before general notification, allowing staff to investigate. General alarm follows after a delay or confirmation.

Related: Alarm Signal, Notification Appliance
Supervising Station

A facility that receives signals from a protected premises fire alarm system and takes action, such as notifying the fire department. It may be central station, proprietary, or remote.

Related: Fire Alarm Control Unit, Alarm Signal