NIULPE 2nd Class flashcards
NIULPE 2nd Class · Build recall with a focused review session.
39 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Maximum allowable working pressure
- The highest pressure at which a boiler or pressure vessel may be operated, set by the weakest pressure-containing part and stamped on the nameplate. Safety valve settings cannot exceed it.
- Fusible plug
- A brass fitting with a low-melting alloy core installed in the crown sheet or upper firebox. It melts near 445 °F when uncovered by water, releasing steam into the furnace as a low-water warning.
- Try lever test
- A manual check that a safety valve opens freely, performed with the boiler at no less than 75 percent of set pressure. It proves freedom of movement, not the popping pressure.
- Gauge glass lowest reading
- The bottom of the visible water glass must align with the lowest permissible water level. Operating below that line risks uncovering heating surface and overheating the metal.
- Stoichiometric air
- The exact mass of air needed to burn a fuel completely with no oxygen left over. Natural gas requires about 17.2 pounds of air per pound of fuel.
- Excess air
- Air supplied beyond the stoichiometric amount, expressed as a percentage. It ensures complete combustion but raises stack loss; typical targets are 5 to 15 percent depending on fuel.
- Pre-purge
- A forced flow of air through the furnace and gas passages before ignition, measured in air changes, that clears any accumulated combustible gases before the burner is lit.
- Trial for ignition
- The limited time after the fuel valve opens during which the flame scanner must prove main flame. If no signal appears, the burner management system closes the fuel valve.
- Deaerator
- A vessel that heats feedwater to saturation to drive off dissolved oxygen and other gases. It typically holds oxygen below 7 parts per billion with a chemical scavenger.
- Economizer
- A heat exchanger that transfers heat from flue gas to incoming feedwater, raising boiler efficiency. Inlet temperature must stay above the acid dew point to prevent corrosion.
- Blowdown percentage
- The fraction of feedwater deliberately discharged to control dissolved solids, calculated as blowdown flow divided by feedwater flow times 100. It equals steam flow plus blowdown in balance.
- Steam trap
- An automatic valve that discharges condensate and non-condensable gases while retaining steam. Types include thermostatic, float-and-thermostatic, inverted bucket, and thermodynamic designs.
- Rankine cycle efficiency
- Net work output divided by heat added in the boiler, computed from steam table enthalpies. The largest loss is heat rejected in the condenser.
- Critical speed
- A rotor speed at which operating speed matches a natural frequency of the shaft assembly, producing high vibration. Turbines accelerate quickly through criticals and never dwell there.
- Overspeed trip
- A protective device that stops steam admission when rotor speed reaches about 110 percent of rated speed. It is tested before startup and after governor maintenance.
- Governor droop
- The speed decrease from no load to full load divided by full-load speed, expressed as a percentage. Isochronous governors have zero droop and hold constant speed on isolated loads.
- NPSH available
- The absolute suction head above the liquid vapor pressure at the pump inlet, after subtracting suction friction losses. It must exceed the pump's required NPSH to prevent cavitation.
- Affinity laws
- Relations for centrifugal pumps: flow varies with speed, head with speed squared, and power with speed cubed. The same relations apply when impeller diameter is changed.
- Best efficiency point
- The flow at which a pump's hydraulic efficiency peaks. Running far from it causes recirculation, vibration, or cavitation and shortens bearing and seal life.
- Compressor surge
- A flow reversal condition in a centrifugal compressor when flow drops below the surge line, causing loud pulsation and possible damage. Anti-surge valves recycle flow to protect the machine.
- Boiler horsepower
- A measure of boiler capacity equal to 33,475 Btu per hour, or about 34.5 pounds of steam per hour evaporated from and at 212 °F.
- Log mean temperature difference
- The driving temperature difference for a heat exchanger, computed as the difference of the two terminal differences divided by the natural log of their ratio.
- Latent heat of vaporization
- The heat required to change water at saturation temperature to saturated steam without a temperature change. At atmospheric pressure it is about 970 Btu per pound.
- Steady-flow energy equation
- For a control volume, heat in minus work out equals the change in enthalpy plus kinetic and potential energy. In a turbine with no heat loss, work equals the enthalpy drop.
- Motor slip
- The difference between synchronous speed and actual rotor speed, divided by synchronous speed. Slip increases with load and is a few percent for induction motors.
- Live zero signal
- A 4 to 20 milliamp instrument loop uses 4 milliamps to represent zero. A reading below 4 milliamps therefore indicates a broken wire or failed transmitter, not a true zero.
- Overload relay
- A starter device that protects a motor from sustained overcurrent by tripping on heat or current. It does not provide short-circuit protection, which the circuit breaker or fuse supplies.
- Fail-safe valve position
- The position a control valve moves to when air or power is lost. Air-to-close valves open on air failure and are chosen when an open path is the safe condition.
- Ton of refrigeration
- A cooling capacity of 12,000 Btu per hour, equivalent to melting one ton of ice per day. It is the standard unit for rating refrigeration and air conditioning equipment.
- Superheat
- The temperature of refrigerant vapor above its saturation temperature at the same pressure. Measured at the evaporator outlet, it protects the compressor from liquid slugging.
- Condenser approach
- The difference between condensing temperature and the entering cooling medium temperature. A rising approach indicates fouling, scale, or non-condensable gases in the condenser.
- Chilled water capacity
- For water, cooling capacity in Btu per hour equals 500 times flow in gallons per minute times the temperature rise in degrees Fahrenheit across the coil.
- Lockout/tagout
- A procedure that isolates every energy source, applies a personal lock for each worker, and verifies zero energy before work. Only the person who applied a lock removes it.
- Confined space atmospheric test
- Testing for oxygen, flammable gas, and toxic gas before entry and continuously during occupancy. Acceptable oxygen ranges from 19.5 to 23.5 percent by volume.
- Hot work permit
- A written authorization for welding, cutting, or grinding that requires removal of combustibles, gas testing, and a fire watch during and after the work.
- OEE
- Overall equipment effectiveness, the product of availability, performance, and quality, each measured against planned production time. It shows where losses occur in a plant.
- MTBF
- Mean time between failures, calculated as total operating time divided by the number of failures. It is a reliability measure used to set maintenance intervals and spares levels.
- Predictive maintenance
- Maintenance triggered by measured condition such as vibration, oil analysis, or thermography, rather than by calendar time. It catches faults before failure and avoids unnecessary work.
- Critical spare part
- A stocked item whose failure would cause long downtime or a safety hazard and whose lead time is long. Consequence and lead time, not price, set the stocking decision.