CCNT study materials
CCNT study resources

CCNT cheat sheet

CCNT · Keep the key ideas within reach.

Quick reference

Neuroanatomy and Neurophysiology

  • Upper motor neuron lesions produce spasticity, hyperreflexia, and Babinski sign; lower motor neuron lesions produce flaccidity, atrophy, fasciculations, and areflexia.

  • The pyramidal (corticospinal) tract decussates in the medulla; the lateral corticospinal tract controls distal limb muscles.

  • The basal ganglia modulate movement via direct (facilitatory) and indirect (inhibitory) pathways; dopamine from substantia nigra pars compacta facilitates the direct pathway.

  • The cerebellum coordinates voluntary movement, balance, and motor learning; lesions cause ipsilateral ataxia, dysmetria, and intention tremor.

  • The thalamus is the major sensory relay to the cortex (except olfaction); the VPL relays body sensation, VPM relays face sensation.

  • The brachial plexus derives from C5–T1 roots; the lumbosacral plexus from L1–S4; nerve root compression produces radicular pain in a dermatomal pattern.

  • The autonomic nervous system: sympathetic preganglionic fibers are thoracolumbar (T1–L2), parasympathetic are craniosacral (CN III, VII, IX, X, S2–S4).

  • The circle of Willis connects anterior and posterior circulations via the anterior and posterior communicating arteries; the middle cerebral artery supplies the lateral cortex and internal capsule.

  • The blood-brain barrier is formed by tight junctions of capillary endothelial cells, astrocytes, and pericytes; it excludes many drugs and large molecules.

Quick reference

Instrumentation, Electronics, and Electrical Safety

  • Differential amplifier rejects common-mode signals; common-mode rejection ratio (CMRR) = 20 log10(differential gain / common-mode gain), ideally >100 dB.

  • Input impedance of an EEG amplifier should be at least 10 MΩ (ideally >100 MΩ) to minimize signal attenuation from high electrode impedance.

  • The Nyquist theorem: sampling rate must be at least twice the highest frequency of interest; for EEG up to 70 Hz, sample at ≥140 Hz (commonly 256–512 Hz).

  • Analog-to-digital resolution: 1 LSB = full-scale voltage / 2^n; a 16-bit ADC over ±5 V has LSB ≈ 0.15 µV.

  • High-pass filter (low-frequency filter) removes slow drift; low-pass filter (high-frequency filter) removes muscle and mains noise; notch filter removes 50/60 Hz.

  • Patient leakage current limits: <100 µA normal condition, <500 µA single-fault condition for type BF/CF applied parts (IEC 60601-1).

  • Ground electrode is not a current return path for the patient; it provides a reference for the amplifier and must be connected to earth.

  • Impedance should be balanced across active and reference electrodes; imbalance degrades CMRR and increases 60 Hz artifact.

Quick reference

Electroencephalography (EEG): Recording Techniques and Montages

  • International 10–20 system: electrodes placed at 10% or 20% of the nasion–inion and preauricular distances; odd numbers left, even numbers right, z midline.

  • Referential montage uses a common reference (e.g., Cz, linked ears, average); bipolar montage displays differences between adjacent electrodes in chains.

  • The longitudinal bipolar (double banana) montage chains: Fp1-F3-C3-P3-O1 and Fp2-F4-C4-P4-O2, plus temporal chains Fp1-F7-T3-T5-O1 and Fp2-F8-T4-T6-O2.

  • The transverse bipolar montage chains across the head: F7-F3-Fz-F4-F8, T3-C3-Cz-C4-T4, T5-P3-Pz-P4-T6.

  • Polarity convention: input 1 more negative than input 2 produces an upward deflection (negative up).

  • Electrode impedance should be <5 kΩ and balanced; check impedance before and periodically during recording.

  • The 10–20 system includes Fp1/2, F3/4, C3/4, P3/4, O1/2, F7/8, T3/4, T5/6, Fz, Cz, Pz; additional electrodes (e.g., T1/T2, Oz) may be used.

  • Activation procedures: hyperventilation (3–5 min) provokes absence seizures and slowing; photic stimulation at 1–30 Hz assesses photoparoxysmal response.

Quick reference

Normal and Abnormal EEG Patterns

  • Normal adult awake background: posterior alpha rhythm 8–13 Hz, reactive to eye opening; beta activity >13 Hz often frontal.

  • Normal sleep stages: N1 (theta, vertex sharp waves), N2 (sleep spindles 12–14 Hz, K-complexes), N3 (delta <2 Hz, >75 µV), REM (low-voltage mixed frequency, sawtooth waves).

  • Benign variants: mu rhythm (7–11 Hz, arch-shaped, central, reactive to movement), 14 and 6 Hz positive bursts, wicket spikes, rhythmic midtemporal theta of drowsiness (RMTD).

  • Epileptiform discharges: spikes (<70 ms), sharp waves (70–200 ms), spike-and-wave complexes; 3 Hz generalized spike-wave is classic for absence epilepsy.

  • Focal slowing (delta/theta) suggests a structural lesion; generalized slowing suggests encephalopathy or metabolic disturbance.

  • Periodic patterns: PLEDs (periodic lateralized epileptiform discharges) in acute structural lesions; triphasic waves in metabolic encephalopathy (often hepatic).

  • Burst suppression: high-voltage bursts alternating with suppression, seen in deep anesthesia, hypothermia, or severe encephalopathy.

  • Electrocerebral inactivity (ECI): no activity >2 µV during a 30-minute recording at increased sensitivity; used in brain death determination.

Quick reference

Evoked Potentials (Visual, Brainstem Auditory, Somatosensory)

  • Visual evoked potential (VEP): pattern-reversal stimulation; P100 wave (positive, ~100 ms) is the most reliable; prolonged latency in optic neuritis and demyelinating disease.

  • Brainstem auditory evoked potential (BAEP): waves I–V; wave I from auditory nerve, wave III from superior olive, wave V from inferior colliculus; interpeak I–III, III–V, I–V latencies.

  • BAEP is resistant to sedation and useful in comatose patients; prolonged I–V interpeak latency suggests brainstem dysfunction.

  • Somatosensory evoked potential (SSEP): median nerve stimulation at wrist, recording over Erb's point, cervical spine (N13), and scalp (N20); prolonged N20 latency indicates central conduction delay.

  • SSEP of posterior tibial nerve records lumbar (N22), cervical, and cortical (P37) responses; useful for spinal cord monitoring.

  • For SSEP, limb temperature should be kept warm (>32°C) because hypothermia prolongs latencies.

  • Evoked potential waveforms are averaged over hundreds to thousands of trials to improve signal-to-noise ratio; artifact rejection is essential.

  • In intraoperative monitoring, SSEP and MEP changes >50% amplitude or >10% latency increase warrant alerting the surgeon.

Quick reference

Nerve Conduction Studies and Electromyography

  • Motor nerve conduction: supramaximal stimulation, record compound muscle action potential (CMAP); measure latency, amplitude, conduction velocity, and F-wave.

  • Sensory nerve conduction: record sensory nerve action potential (SNAP); amplitude reflects axonal loss, latency reflects demyelination.

  • Conduction velocity (m/s) = distance (mm) / latency difference (ms); typical median motor velocity 49–65 m/s.

  • Prolonged distal latency and slowed conduction velocity with preserved amplitude suggest demyelination; reduced amplitude with normal velocity suggests axonal loss.

  • F-wave latency reflects proximal conduction; prolonged F-wave suggests radiculopathy or proximal demyelination.

  • EMG: insertional activity, spontaneous activity (fibrillations, positive sharp waves), motor unit action potentials (MUAPs), and recruitment pattern.

  • Fibrillations and positive sharp waves indicate active denervation; large polyphasic MUAPs indicate chronic reinnervation.

  • Reduced recruitment (fewer MUAPs firing faster) suggests neuropathic loss; early recruitment of small MUAPs suggests myopathy.

  • H-reflex assesses S1 root and tibial nerve; prolonged H-reflex latency suggests S1 radiculopathy.

Quick reference

Patient Care, Safety, and Infection Control

  • Hand hygiene is the single most effective infection control measure; use alcohol-based rub or soap and water before and after patient contact.

  • Standard precautions apply to all patients: gloves for contact with blood/body fluids, gowns for splashes, masks/eye protection as needed.

  • Needlestick injury: wash with soap and water, report immediately, and follow post-exposure prophylaxis protocol; HIV PEP should start within hours.

  • Electrode application sites should be cleaned with alcohol and dried; abraded skin increases infection risk and should be avoided unless necessary.

  • Patients with implanted cardiac pacemakers or defibrillators require careful electrode placement and monitoring; avoid current paths through the chest.

  • Seizure during EEG: note time, duration, and semiology; do not restrain the patient; protect from injury; suction and oxygen available.

  • Fall precautions: assist patients with mobility issues; ensure bed rails and call bell within reach.

  • Documentation of patient care includes vital signs, medications, allergies, and any adverse events during the procedure.

Quick reference

Professional Standards, Ethics, and Documentation

  • Informed consent must be obtained before invasive or non-routine procedures; document the discussion and patient understanding.

  • Patient confidentiality is protected by HIPAA; disclose information only on a need-to-know basis and secure records.

  • Scope of practice: technologists perform tests and report findings but do not independently diagnose or prescribe treatment.

  • Documentation must be accurate, timely, and legible; include date, time, procedure, patient response, and any deviations from protocol.

  • Avoid altering records; corrections should be dated, signed, and explained, with the original entry still visible.

  • Report unsafe practices or equipment malfunctions through the chain of command and incident reporting systems.

  • Professional boundaries: do not accept gifts that could influence judgment; avoid dual relationships with patients.

  • Continuing education and certification maintenance (e.g., ABRET) are required to ensure competence and uphold professional standards.