NORMI CMA: Indoor Air Quality (IAQ) and Allergens

NORMI CMA · Work through your exam, one topic at a time.

All guide sections

Indoor Air Quality (IAQ) and Allergens

What this domain tests

IAQ and allergens tests whether you can identify sources, evaluate ventilation and filtration, and recommend controls in the right order: source control, ventilation, then air cleaning.

Core rules

  • Common indoor allergens include dust mites, pet dander, cockroach allergen, pollen, and mold. Dust mites and mold need moisture control; pets and pests need source and cleaning controls.
  • ASHRAE 62.1-style ventilation supplies outdoor air for occupants. CO2 is a ventilation indicator, not a direct toxin measure. High CO2 suggests inadequate outdoor air if occupancy and calibration are known.
  • Filtration uses MERV ratings; higher MERV captures more particles but must match fan capacity and pressure drop.
  • Keep indoor RH roughly 30-50% where possible. Excess humidity supports mites and mold; over-drying causes discomfort.
  • Combustion appliances need venting and CO alarms. VOCs and formaldehyde come from furnishings, cleaners, and building materials.
  • Investigate occupant complaints with interviews, walkthroughs, moisture and CO/CO2 measurements, and HVAC inspection.

Worked example

A classroom reports stuffiness; CO2 reads 1,800 ppm with 30 students. Reasoning: this is a ventilation indicator. Check outdoor-air damper, fan operation, and occupancy schedule before blaming a pollutant. Increasing outdoor air and verifying airflow is the first control; a portable purifier is supplemental.

Traps

  • Treating an air purifier as a substitute for ventilation or source control.
  • Interpreting a single CO2 reading without occupancy or calibration data.
  • Ignoring combustion safety and CO.
  • Recommending humidity below 30% or above 50% without justification.
  • Assuming all odors are mold.