Galvanic series
A ranking of metals by electrochemical potential in a given electrolyte. Metals farther apart on the list corrode faster when coupled in moisture.
Sacrificial anode
The less noble metal in a galvanic couple that corrodes to protect the cathode. Zinc coatings on steel act this way at cut edges and scratches.
Copper runoff staining
Water carrying dissolved copper salts stains light masonry and accelerates corrosion of zinc and aluminum below. Route drainage away from those metals.
Bend allowance
The length of neutral axis consumed by a bend, calculated as (π/180) × angle × (inside radius + K × thickness). Subtract it when laying out flat patterns.
Ounce weight copper
Copper sheet thickness stated as weight per square foot. 16 oz copper is 0.0216 in thick; 20 oz is 0.027 in.
Reglet
A groove cut or cast into masonry or concrete to receive the turned edge of flashing. Depth is typically a minimum of 3/4 in.
Counterflashing
Metal lapping over the top of base flashing to shed water and hide the joint. It must lap at least 4 in and terminate in a reglet or sealed surface mount.
Through-wall flashing
Flashing installed within a wall cavity to divert water to the exterior. It laps shingle-style and ends with a drip beyond the wall face.
Weep hole spacing
Openings above through-wall flashing that let cavity moisture escape. Typical spacing is 24 to 32 in on center, with end dams at terminations.
Coping drip
A formed edge on parapet coping that sheds water clear of the wall face. Coping needs a drip on both faces and clips allowing thermal movement.
Base flashing height
The vertical dimension of flashing above the roof surface. Common minimum is 8 in, with at least 4 in of lap over the membrane.
Drip edge standoff
The projection of edge metal past the fascia that keeps water off the wall. A minimum 1/4 in kick-out is typical.
Gravel stop
Edge metal that retains ballast and finishes the roof perimeter. It requires a continuous cleat and sealed corner laps.
Termination bar
A clamped metal bar that secures membrane or flashing edges. Fasteners are staggered and the bar is sealed to prevent a continuous split.
Roof-to-wall cant
A triangular fillet at the base of a wall that supports the flashing and avoids a sharp bend. Flashing must not bridge a gap.
Expansion joint allowance
Thermal movement accommodated in long metal runs. Copper moves roughly 1/8 in per 10 ft of length over normal temperature swings.
Overflow scupper
A secondary drainage opening through a parapet set above the primary drain. It must be independent and discharge visibly so blockage is noticed.
Rational method
Q = C × I × A estimates peak runoff from runoff coefficient, rainfall intensity, and area. It sizes gutters, leaders, and scuppers.
Leader capacity
The roof area a downspout can drain at design rainfall. A 3 in round leader handles roughly 1,000 to 1,200 sq ft at 1 in/hr.
Gutter hanger spacing
Bracket or strap spacing along a gutter run. Typical is 24 to 36 in on center, closer in snow-load regions, with room for thermal movement.
Pitch pan
A sealant-filled pan around a penetration, used where a manufactured boot will not fit. It is a last resort requiring periodic replenishment.
Curb height minimum
The height of a skylight or equipment curb above the finished roof. Common minimum is 8 in, increased in snow country.
Step flashing
Individual pieces lapped shingle-style along a chimney or wall, each set into the masonry or siding course. It works with base and cap flashing.
Condensation gutter
A channel inside a skylight curb that collects interior condensation and routes it outside, preventing water staining below the unit.
Vent stack boot
A two-piece flashing with a base flange lapped over the membrane and a collar clamped to the pipe. The top must be sealed to the stack.
Dissimilar metal isolation
Separating unlike metals with bituminous coating, EPDM tape, plastic washers, or insulated fasteners to break the galvanic cell.
Dezincification
Selective leaching of zinc from brass in aggressive water or soil, leaving a weak porous copper structure. Specify resistant alloys in these conditions.
Neutral-cure silicone
A low-modulus sealant for moving joints that does not corrode metal. It is not a substitute for proper laps in concealed flashing.
Soldering copper
Joining copper with 50/50 or 95/5 tin-antimony solder and flux. Joints must be clean and tight-lapped, and flux residue removed to stop corrosion.
Fall protection threshold
OSHA requires guardrails, nets, or personal fall arrest at 6 ft above a lower level in construction. Roof work must comply before access.
Hot work permit
Authorization required for soldering and brazing, with a fire watch and clearance from combustibles. A heat shield protects membrane near the work.
Manufacturer instructions
Published installation requirements for fasteners, spacing, sealant, and substrate preparation. Deviating from them typically voids the material warranty.