Picocurie per liter (pCi/L)

The unit used to report radon concentration in air, equal to one trillionth of a curie per liter. U.S. programs commonly use 4 pCi/L as an action level.

Related: Action level, Working level, Becquerel per cubic meter
Becquerel per cubic meter (Bq/m3)

The SI unit for radon activity concentration, equal to one decay per second in a cubic meter. One pCi/L equals about 37 Bq/m3.

Related: Picocurie per liter (pCi/L), Working level
Working level (WL)

A measure of the potential alpha energy from short-lived radon decay products in a liter of air, used mainly in occupational and mine settings rather than in homes.

Related: Working level month, Radon decay products
Working level month (WLM)

An exposure unit equal to breathing air at one working level for about 170 hours, used to express cumulative radon progeny exposure for workers.

Related: Working level (WL), Radon decay products
Action level

The radon concentration at which mitigation or further evaluation is recommended. In U.S. residential guidance it is 4 pCi/L, with consideration of action between 2 and 4 pCi/L.

Related: Picocurie per liter (pCi/L), Mitigation
Radon

A colorless, odorless radioactive gas produced by the decay of radium in soil and rock. It seeps into buildings and is the leading environmental cause of lung cancer among nonsmokers.

Related: Radon decay products, Radium, Soil gas
Radon decay products

Short-lived radioactive solids such as polonium, lead, and bismuth that form when radon decays. They attach to dust and can deposit in the lungs, delivering most of the dose.

Related: Radon, Working level (WL), Attachment fraction
Radium

A radioactive metal found in soil and rock that decays into radon. Its concentration in surrounding material largely determines how much radon gas can be produced.

Related: Radon, Soil gas
Half-life

The time required for half of a radioactive substance to decay. Radon-222 has a half-life of about 3.8 days, which affects how long test devices must be exposed.

Related: Radon, Radon decay products, Exposure period
Soil gas

Air present in pore spaces between soil particles. Radon-laden soil gas enters buildings through cracks, sumps, and other openings driven by pressure differences.

Related: Stack effect, Radon, Sub-slab depressurization
Stack effect

The upward flow of indoor air caused by warm air rising and leaving through upper openings, which lowers indoor pressure and draws soil gas into the building.

Related: Soil gas, Sub-slab depressurization, Pressure differential
Pressure differential

The difference in air pressure between indoor and outdoor or sub-slab environments. Even small negative indoor pressures can pull radon-containing soil gas indoors.

Related: Stack effect, Soil gas
Closed-house conditions

Test conditions requiring exterior doors and windows to remain closed, typically for at least 12 hours before and throughout the test, to measure representative radon levels.

Related: Exposure period, Short-term test, Test placement
Short-term test

A radon measurement lasting from a few days to about 90 days, often using charcoal or electret devices. It provides a quick screening result that may need confirmation.

Related: Long-term test, Closed-house conditions, Charcoal canister
Long-term test

A radon measurement lasting more than 90 days, usually with an alpha track or electret device. It better reflects the year-round average because seasonal variation is averaged out.

Related: Short-term test, Alpha track detector, Seasonal variation
Charcoal canister

A passive short-term device containing activated charcoal that adsorbs radon for a set exposure period, then is analyzed in a lab to estimate average concentration.

Related: Short-term test, Exposure period, Electret ion chamber
Electret ion chamber

A passive device that uses a charged electret to collect ions produced by radon decay; the voltage drop is measured to calculate radon concentration over the exposure period.

Related: Charcoal canister, Alpha track detector
Alpha track detector

A passive long-term device with a plastic film that records alpha particle tracks from radon decay. Tracks are counted after processing to determine average radon concentration.

Related: Long-term test, Electret ion chamber
Continuous radon monitor

An electronic device that samples air and reports radon concentration at intervals, often storing hourly data and recording conditions such as temperature and pressure.

Related: Closed-house conditions, Short-term test, Quality assurance
Test placement

Choosing device locations that represent breathing air, such as lowest livable levels, while avoiding bathrooms, kitchens, and areas near drafts, heat, or exterior walls.

Related: Closed-house conditions, Lowest livable level
Lowest livable level

The lowest floor of a building that is used regularly, such as a basement or ground floor. Radon testing is normally performed there because concentrations tend to be highest.

Related: Test placement, Foundation type
Exposure period

The planned duration during which a radon measurement device is exposed to indoor air. It must match the device's design and the test protocol to produce valid results.

Related: Short-term test, Long-term test, Closed-house conditions
Seasonal variation

Changes in indoor radon concentration across the year caused by weather, heating, and ventilation patterns. Long-term tests reduce its effect on reported averages.

Related: Long-term test, Closed-house conditions
Interference

Any condition or activity that can bias a radon measurement, such as opened windows, fans, fireplaces, or unusual weather, which must be documented and avoided.

Related: Closed-house conditions, Quality assurance
Quality assurance (QA)

Planned activities that ensure radon measurements meet defined standards, including calibration, duplicate and blank measurements, audits, and documented procedures.

Related: Quality control, Spike measurement, Duplicate measurement
Quality control (QC)

Routine checks performed during measurement work, such as duplicates, blanks, and calibration verification, to detect errors and confirm that results are reliable.

Related: Quality assurance (QA), Duplicate measurement, Blank measurement
Duplicate measurement

Two devices deployed side by side at the same time and location. Comparing their results helps verify precision and detect handling or analysis problems.

Related: Quality control (QC), Blank measurement, Spike measurement
Blank measurement

A device handled and shipped like a field device but not exposed to the test environment. Its result checks for contamination or lab background during processing.

Related: Duplicate measurement, Quality control (QC)
Spike measurement

A device exposed to a known radon concentration, often in a chamber, to verify that a measurement system reports accurately across its working range.

Related: Quality assurance (QA), Calibration
Calibration

The process of comparing an instrument's response to a known reference standard and adjusting or documenting its accuracy so reported concentrations are traceable.

Related: Spike measurement, Quality assurance (QA)
Chain of custody

Documentation tracking a measurement device from deployment through shipping and laboratory analysis, showing who handled it and when at each step.

Related: Exposure period, Quality assurance (QA)
Mitigation

Building techniques that reduce indoor radon entry or increase ventilation, such as sub-slab depressurization, sealing, or ventilation, applied when test results warrant action.

Related: Sub-slab depressurization, Action level
Sub-slab depressurization

A common mitigation method that uses a fan and piping to draw soil gas from beneath the foundation and vent it outdoors, lowering pressure under the slab.

Related: Soil gas, Mitigation, Stack effect
Post-mitigation test

A radon measurement performed after mitigation is complete to confirm that concentrations have been reduced to acceptable levels and the system is working.

Related: Mitigation, Action level
Foundation type

The construction of a building's base, such as basement, slab-on-grade, or crawlspace. It influences radon entry routes, testing strategy, and mitigation design.

Related: Lowest livable level, Soil gas
Radon potential

An estimate of the likelihood that a building in a given area will have elevated radon, based on geology, soil, and building characteristics. It guides testing priorities.

Related: Soil gas, Foundation type
Attachment fraction

The proportion of radon decay products that attach to airborne particles rather than remaining unattached. It affects where progeny deposit in the respiratory tract.

Related: Radon decay products, Working level (WL)
Real estate measurement

A radon test performed as part of a property transaction, which must follow strict placement, closure, and documentation requirements so results are defensible.

Related: Closed-house conditions, Test placement