- Radon-222 half-life
- Radon-222 has a half-life of 3.82 days and decays by alpha emission to polonium-218. This short half-life allows both short-term and long-term measurement strategies.
- Working level definition
- One working level is any combination of short-lived radon progeny in one liter of air that emits 1.3 × 10^5 MeV of alpha energy. It equals 100 pCi/L radon at 100% equilibrium.
- Working level month
- One WLM is exposure to one working level for 170 hours. It is the standard unit for cumulative radon progeny exposure and occupational dose assessment.
- Equilibrium fraction F
- The ratio of progeny activity concentration to parent radon activity concentration at a given time. Indoors F is typically 0.3 to 0.7 and depends on ventilation and aerosol conditions.
- pCi/L to Bq/m3
- One picocurie per liter equals 37 becquerels per cubic meter. To convert pCi/L to Bq/m³, multiply by 37; to convert Bq/m³ to pCi/L, divide by 37.
- Pressure-driven soil gas entry
- The dominant radon entry mechanism in most buildings. Indoor-outdoor pressure differences caused by stack effect, exhaust fans, and wind draw soil gas containing radon through foundation cracks and openings.
- Diffusion entry
- Radon moves from soil into buildings by molecular diffusion along a concentration gradient. It is generally a minor entry pathway compared with pressure-driven flow but matters in highly permeable soils.
- Emanation
- The release of radon atoms from solid grains into the surrounding pore space. Emanation coefficient depends on radium distribution, grain size, and moisture content of the material.
- Secular equilibrium time
- Short-lived radon progeny reach secular equilibrium with radon after about 3 to 4 hours in a closed environment. This timing is critical when using progeny measurement methods.
- Alpha track detector
- A passive radon measurement device using a plastic film that records alpha particle tracks. Tracks are chemically etched and counted to determine integrated radon concentration over deployment periods of one to twelve months.
- Electret ion chamber
- A passive radon monitor using a charged electret whose voltage decreases as radon decay products ionize the chamber air. Voltage drop is proportional to integrated radon concentration.
- Charcoal canister
- A short-term passive radon device using activated charcoal to adsorb radon. It is deployed for two to seven days and analyzed by gamma spectroscopy; results are sensitive to humidity and temperature.
- Continuous radon monitor
- An active electronic instrument that measures radon concentration at intervals and records a time series. It can detect diurnal variation, tampering, and abnormal events during short-term tests.
- Closed-house test conditions
- For short-term radon tests, all exterior doors and windows are kept closed and fans or other air-moving devices are not operated for at least 12 hours before and during the test, except for normal entry and exit.
- Test placement height
- Detectors are placed in the lowest lived-in level of the home, at least 20 inches above the floor, away from exterior walls, drafts, heat sources, and direct sunlight.
- Duplicate and blank detectors
- Quality control in radon measurement includes duplicate detectors at a rate of at least 10 percent and field blanks at least 5 percent to assess precision and contamination.
- Spike measurement
- A known radon concentration is added to a detector or chamber to verify accuracy. Spikes are part of quality assurance programs and help confirm calibration and analysis bias.
- Radon in water measurement
- Waterborne radon is measured by liquid scintillation counting or gamma spectroscopy after careful sample collection. It contributes to indoor radon through household water use, especially showers.
- Radon in soil gas
- Soil gas radon is sampled with probes inserted into the ground and analyzed for concentration and permeability. It informs sub-slab depressurization design and radon potential assessments.
- Radon potential
- An estimate of the indoor radon concentration likely in a building at a location, based on geology, soil gas radon, and building characteristics. It guides testing and mitigation decisions.
- Short-term test duration
- Short-term radon tests last from two to ninety days depending on the device. Charcoal canisters are typically two to seven days, while alpha track detectors can be deployed for months.
- Long-term test duration
- Long-term radon tests last more than ninety days, typically three to twelve months. They provide a more representative annual average because they capture seasonal variation.
- Radon action level
- The U.S. EPA recommends mitigation when a long-term test average is 4 pCi/L or higher. The World Health Organization recommends a reference level of 100 Bq/m³.
- Radon measurement plan
- A written document describing sampling design, device placement, chain of custody, quality control, and reporting for a radon measurement project. It ensures consistency and defensibility.
- Chain of custody
- A documented record tracking radon detectors from deployment through retrieval, shipping, and laboratory analysis. It preserves sample integrity and supports data defensibility.
- Detector deployment log
- A field record noting detector identification, location, placement height, start and end times, and environmental conditions. It supports quality assurance and data interpretation.
- Radon entry through crawl spaces
- Crawl spaces can act as collection plenums for soil gas. Radon can move from the crawl space into living areas through pressure-driven flow and openings in the floor.
- Sub-slab depressurization
- A mitigation technique that uses a fan and piping to create negative pressure beneath the slab, preventing soil gas from entering the building. It is the most common radon reduction method.
- Radon progeny plate-out
- The deposition of charged radon decay products onto surfaces such as walls and furniture. Plate-out reduces the airborne progeny concentration and lowers the equilibrium fraction.
- Radon measurement uncertainty
- The combined uncertainty from detector calibration, counting statistics, and environmental variation. It is reported with results and used to decide whether a result exceeds an action level.
- Radon chamber calibration
- Detectors are exposed to a known radon concentration in a controlled chamber to determine calibration factors. Chambers are traceable to national standards and are part of quality assurance.
- Radon test interference
- Events such as opening windows, operating exhaust fans, or unusual weather can bias short-term radon results. Monitors and field logs help identify interference during the test.