NRSB RMT key terms
NRSB RMT · Get comfortable with the vocabulary.
- Radon (Rn-222)
- Related: Radium-226, Progeny
A colorless, odorless, radioactive noble gas produced by the decay of radium-226; it seeps from soil and rock into buildings and is the leading environmental cause of lung cancer after smoking.
- Radon progeny
- Related: Radon (Rn-222), Working Level
The short-lived solid decay products formed after radon decays, including polonium-218, lead-214, bismuth-214, and polonium-214; these emit alpha particles and deliver most of the lung dose.
- Radium-226
- Related: Radon (Rn-222), Uranium-238
A radioactive metal in the uranium-238 decay chain with a 1,600-year half-life; it decays into radon gas and is the parent nuclide that supplies radon in soil and building materials.
- Uranium-238
- Related: Radium-226, Radon Potential
The long-lived primordial isotope that begins the decay series leading through radium-226 to radon; its concentration in underlying rock and soil largely determines regional radon potential.
- Half-life
- Related: Decay Constant, Radon (Rn-222)
The time required for half the atoms of a radioactive substance to decay; radon-222's 3.8-day half-life lets it migrate from soil into buildings but limits how far it travels.
- Decay constant
- Related: Half-life, Secular Equilibrium
The probability per unit time that a given radioactive atom will decay, equal to the natural logarithm of two divided by the half-life; used in activity and equilibrium calculations.
- Becquerel (Bq)
- Related: Picocurie per Liter, Activity Concentration
The SI unit of radioactivity equal to one nuclear transformation per second; radon concentrations are often reported in becquerels per cubic meter (Bq/m3).
- Picocurie per liter (pCi/L)
- Related: Becquerel (Bq), Action Level
The customary U.S. unit for radon gas concentration in air, where one picocurie equals 0.037 becquerels; U.S. action and mitigation decisions are usually expressed in this unit.
- Working Level (WL)
- Related: Working Level Month, Potential Alpha Energy
A historical unit describing the concentration of radon progeny that releases a defined amount of potential alpha energy per liter of air; it applies to decay products, not to radon gas itself.
- Working Level Month (WLM)
- Related: Working Level, Occupational Exposure
A cumulative exposure unit equal to breathing air at one Working Level for 170 hours; it combines progeny concentration and time and is used in occupational and epidemiological dose estimates.
- Potential alpha energy
- Related: Working Level, Radon Progeny
The total alpha energy that would be released as a radon progeny mixture decays to long-lived lead-210; it is the physical quantity underlying Working Level measurements.
- Secular equilibrium
- Related: Equilibrium Ratio, Decay Constant
A steady condition in which a parent nuclide's half-life is far longer than its progeny's, so progeny activity equals parent activity; radon and its short-lived progeny approach this state in closed spaces.
- Equilibrium ratio
- Related: Secular Equilibrium, Plate-out
The ratio of measured radon progeny activity to the radon gas activity present; values below one reflect ventilation, plate-out, or dust conditions that shift progeny away from equilibrium.
- Plate-out
- Related: Equilibrium Ratio, Radon Progeny
Deposition of charged radon progeny onto walls, floors, and furniture, removing them from the breathing air; it lowers measured progeny concentrations and affects equilibrium assumptions.
- Action level
- Related: Picocurie per Liter, Mitigation
The radon concentration at which mitigation is recommended; U.S. guidance sets 4 pCi/L for homes and 2 to 4 pCi/L as a range for considering action in schools and workplaces.
- EPA action level
- Related: Action Level, Follow-up Test
The 4 pCi/L indoor radon threshold in U.S. Environmental Protection Agency guidance; results at or above it generally prompt confirmatory testing and consideration of mitigation.
- Radon potential
- Related: Uranium-238, Zone Designation
A prediction of the indoor radon concentration a building could reach based on geology, soil, and construction factors; it is mapped by region and does not replace measurement of an individual building.
- Zone designation
- Related: Radon Potential, Real Estate Transaction Test
A classification of geographic areas by predicted average indoor radon potential, commonly zone 1 (highest), zone 2 (moderate), and zone 3 (low); it guides testing priorities, not individual building conclusions.
- Short-term test
- Related: Long-term Test, Closed-House Conditions
A radon measurement lasting from a few days to about 90 days, typically using charcoal or electret devices; it gives a quick screening result but is more sensitive to weather and seasonal variation.
- Long-term test
- Related: Short-term Test, Alpha-Track Detector
A radon measurement lasting more than 90 days, usually with alpha-track detectors; it averages seasonal swings and better estimates the year-round concentration a occupant actually experiences.
- Closed-house conditions
- Related: Short-term Test, Test Placement
Test protocols requiring exterior doors and windows kept closed and permanent ventilation shut for a set period before and during sampling, so results reflect normal occupied conditions without excess ventilation.
- Follow-up test
- Related: Action Level, Short-term Test
A second measurement made after an initial short-term result at or above the action level, intended to confirm the concentration before a mitigation decision is made.
- Test placement
- Related: Closed-house Conditions, Sampling Protocol
Choosing detector locations that represent breathing-zone conditions, such as the lowest livable level, away from exterior walls, drafts, heat sources, and moisture, while avoiding kitchens and bathrooms.
- Sampling protocol
- Related: Test Placement, Chain of Custody
The documented set of procedures for device deployment, exposure duration, retrieval, and documentation that must be followed so results are valid and defensible.
- Chain of custody
- Related: Sampling Protocol, Quality Assurance Plan
A written record tracking each detector from deployment through shipping, analysis, and reporting, showing who handled it and when so results can be trusted in legal or real estate contexts.
- Quality assurance plan
- Related: Quality Control, Chain of Custody
A written program of procedures, responsibilities, and checks ensuring measurements meet defined accuracy and precision goals; it includes calibration, blanks, spikes, duplicates, and audits.
- Quality control
- Related: Quality Assurance Plan, Duplicate Measurement
The routine operational checks that verify individual measurements, such as blanks, duplicates, spikes, and calibration verification, and flag results that fall outside acceptance criteria.
- Spike (spiked sample)
- Related: Quality Control, Blank (Field Blank)
A detector or sample dosed with a known amount of radon or progeny to verify that the measurement system recovers the expected value within acceptance limits.
- Blank (field blank)
- Related: Spike (spiked Sample), Quality Control
An unexposed detector carried and shipped alongside field devices but not deployed for sampling; its result reveals contamination, handling errors, or background in the measurement process.
- Duplicate measurement
- Related: Quality Control, Precision
Two detectors deployed at the same location for the same period to assess measurement precision by comparing their reported results.
- Precision
- Related: Accuracy, Duplicate Measurement
The degree to which repeated measurements under the same conditions agree with each other; it describes random variability and is distinct from accuracy, which concerns closeness to the true value.
- Accuracy
- Related: Precision, Calibration
How close a measured result is to the true radon concentration, reflecting systematic and random error combined; it is assessed through spikes, calibrations, and reference comparisons.
- Calibration
- Related: Accuracy, Traceability
The process of comparing an instrument or detector response against a known reference standard traceable to a national source, and adjusting or correcting results accordingly.
- Traceability
- Related: Calibration, Quality Assurance Plan
An unbroken documented chain linking a measurement result to recognized national or international standards through successive calibrations, establishing the credibility of reported values.
- Charcoal adsorption detector
- Related: Short-term Test, Electret Ion Chamber
A passive short-term device in which activated charcoal collects radon for days, then laboratory analysis measures the collected activity; exposure timing and moisture strongly affect results.
- Alpha-track detector
- Related: Long-term Test, Electret Ion Chamber
A passive long-term device in which alpha particles from radon and progeny leave microscopic tracks in a plastic film, which is etched and counted to estimate average concentration over months.
- Electret ion chamber
- Related: Charcoal Adsorption Detector, Alpha-Track Detector
A passive device that measures radon through voltage change on a charged electret caused by ionizing radiation inside a chamber; usable for short- or long-term exposures with proper calibration.
- Continuous radon monitor
- Related: Short-term Test, Tamper Indication
An electronic instrument that samples air and reports radon concentration at intervals, providing time-series data useful for detecting tampering, ventilation changes, and diurnal patterns.
- Mitigation
- Related: Action Level, Post-Mitigation Test
Building modifications that reduce indoor radon entry or concentration, such as sub-slab depressurization, sealing, or ventilation; testing verifies whether the chosen approach actually works.
- Post-mitigation test
- Related: Mitigation, Action Level
A measurement performed after a mitigation system is operating, conducted under defined conditions, to confirm that indoor radon has been reduced below the action level.