OH Journeyman Plumber study materials
OH Journeyman Plumber study resources

OH Journeyman Plumber study plan

OH Journeyman Plumber · Give each week a clear focus.

8 weeks · About 7 hours per week

Week 1

Drainage, Waste, and Venting & Plumbing Systems and Fixtures

  • Map the DWV domain's 20 percent weight into a checklist of fixture-drain, trap, vent, and building-drain subtopics you will drill each week

  • Trace a full DWV path on paper from a water closet flange through the closet bend, branch, stack, and building drain to the sewer, naming each fitting and its purpose

  • Identify the vent types (individual, common, wet, circuit, stack, relief) and state in writing the condition each one protects against

  • List the trap-seal requirements you must memorize, including seal depth, trap-arm distance limits, and prohibited trap configurations

  • Complete 40 practice items on traps and venting and log every miss with the rule you violated

Your checkpoint

A one-page DWV cheat sheet plus a scored 40-item practice log showing at least 75 percent correct

Week 2

Drainage, Waste, and Venting & Plumbing Systems and Fixtures

  • Calculate drain and vent pipe sizing for a worked example using fixture units and developed length, showing every step

  • Explain the difference between a wet vent and a dry vent and identify three field situations where each is used

  • Describe the correct installation sequence for a water closet, lavatory, and floor drain, including rough-in dimensions and flange height

  • Diagnose five written DWV failure scenarios (gurgling trap, sewer odor, slow drain, bubbling fixture, frozen vent) and prescribe the code-compliant fix for each

  • Recite the slope requirements for drain pipe by size and the cleanout spacing rules from memory in writing

Your checkpoint

A worked fixture-unit sizing problem with full calculations and a five-scenario diagnostic write-up

Week 3

Plumbing Systems and Fixtures & Water Supply and Distribution

  • Catalog the common plumbing fixtures and their required flow rates, fixture-unit values, and minimum trap sizes in a comparison table

  • Describe the water supply distribution layout from meter through main, riser, and branch, including the function of each valve and device

  • Explain backflow prevention devices and identify which cross-connection situations require an air gap versus a vacuum breaker versus a reduced-pressure assembly

  • Compute the minimum required number of fixtures for a small commercial occupancy given occupant load and fixture ratios

  • Complete 40 practice items mixing fixtures and water supply and review every missed item against the code text

Your checkpoint

A fixture-and-flow-rate reference table plus a scored 40-item practice log with written corrections for each miss

Week 4

Water Supply and Distribution & Pipe Materials and Fittings

  • Size a water supply system using demand loading and pressure-loss tables, showing the calculation for a two-bath dwelling

  • Compare copper, PEX, CPVC, and galvanized pipe on pressure rating, joining method, freeze behavior, and approved applications, and write a short selection rationale for each

  • Identify the fittings and joining methods for each pipe material and state the code restriction on mixing materials or using dielectric unions

  • Explain thermal expansion control, water hammer arrestors, and pressure-reducing valve placement in a distribution system

  • Complete 30 practice items on pipe materials and fittings and correct each miss in writing

Your checkpoint

A completed water supply sizing calculation for a two-bath dwelling plus a four-material comparison matrix

Week 5

Plumbing Code and Regulations & Pipe Materials and Fittings

  • Outline the permit, inspection, and testing sequence for a residential plumbing rough-in and final, naming the inspection stage at which each test occurs

  • State the hydrostatic and air test pressure and duration requirements for DWV and water supply systems

  • List the code requirements that most often trigger failed inspections, including support spacing, protection of pipe, and prohibited fittings

  • Describe the licensing and code-adoption framework that governs journeyman plumbers in Ohio, including who adopts the code and what the journeyman is responsible for on site

  • Complete 40 practice items on code and regulations and log the code section behind each missed item

Your checkpoint

A rough-in-to-final inspection timeline with test pressures and durations, plus a scored 40-item code practice log

Week 6

Plumbing Safety and Tool Use & Plumbing Math and Measurement

  • Demonstrate the safe setup and use of the core tools (press tool, tubing cutter, soil pipe cutter, auger, torch) and state the hazard each tool presents

  • Explain confined-space, trenching, and soldering-fire safety practices and the personal protective equipment required for each task

  • Compute pipe offsets, travel, and fitting takeoffs for 45-degree and 22.5-degree offsets and verify your answers with a second method

  • Convert between decimal inches, fractions, and metric units and calculate pipe volume, fixture-unit totals, and developed length from a sketch

  • Complete 25 mixed safety and math practice items and rework every missed calculation until correct

Your checkpoint

A tool-hazard and PPE reference sheet plus a set of five solved offset and takeoff calculations checked two ways

Week 7

Plumbing System Design and Installation & Plumbing Systems and Fixtures

  • Design a complete plumbing layout for a two-bath single-family dwelling, showing fixture placement, DWV routing, vent connections, and water supply branches

  • Justify each sizing decision in the layout by citing the fixture-unit and demand-load basis you used

  • Identify the installation details that differ between a slab-on-grade, crawl space, and basement rough-in and adjust your design accordingly

  • Review your layout against a written self-audit checklist covering trap seals, venting, cleanouts, support, and access

  • Present the design in a short written narrative as if explaining it to an inspecting authority

Your checkpoint

A complete two-bath dwelling plumbing layout with sizing justifications and a completed self-audit checklist

Week 8

Drainage, Waste, and Venting & Water Supply and Distribution & Plumbing Code and Regulations

  • Take two full-length timed practice exams under test conditions and record the score by domain

  • Rank your three weakest subtopics from the practice exams and drill 20 targeted items on each

  • Rewrite your DWV, water supply, and code cheat sheets from memory and compare against your originals to find gaps

  • Review every remaining flagged item from weeks 1 through 7 and resolve each one to a confident answer

  • Build a final one-page pre-exam review sheet limited to the facts you most often missed

Your checkpoint

Two scored timed practice exams with a domain breakdown and a final one-page pre-exam review sheet

Milestones

Week 2: Score at least 75 percent on a 25-item DWV quiz covering traps, vents, slope, and cleanouts, and correctly solve one fixture-unit sizing problem without notes

Week 4: Score at least 80 percent on a 30-item mixed quiz on fixtures, water supply, and pipe materials, and complete a two-bath water supply sizing calculation unaided

Week 6: Score at least 80 percent on a 25-item safety and math quiz, and solve three pipe offset problems correctly using two independent methods

Week 8: Score at least 80 percent overall on each of two timed full-length practice exams, with no single domain below 70 percent