Total Recordable Incident Rate
Multiply the number of OSHA recordable cases by 200,000 and divide by total employee hours worked. The 200,000 constant equals 100 full-time workers at 40 hours for 50 weeks.
DART Rate Calculation
Days Away, Restricted, or Transferred rate: multiply DART cases by 200,000 and divide by hours worked. It counts only recordable cases with days away, restricted work, or job transfer.
Fatality Reporting Deadline
Under 29 CFR 1904.39 an employer must report a work-related fatality to OSHA within 8 hours of learning of it, by telephone or the online reporting form.
General Duty Clause
OSH Act Section 5(a)(1) requires employers to furnish a workplace free from recognized hazards likely to cause death or serious physical harm, where a feasible means of abatement exists.
Hierarchy of Controls
Ranked from most to least effective: elimination, substitution, engineering controls, administrative controls, and personal protective equipment. PPE ranks last because effectiveness depends on individual behavior and fit.
Leading Indicator
A preventive measure that predicts future safety performance, such as inspections completed, near-miss reports, or training hours. It contrasts with lagging indicators like injury and illness rates.
Plan-Do-Check-Act Cycle
The continual improvement model used in ANSI/ASSP Z10 and ISO 45001 safety management systems: establish objectives, implement controls, evaluate results, and correct deficiencies before repeating the cycle.
TLV Short-Term Exposure Limit
A 15-minute time-weighted average concentration that should not be exceeded at any time during the workday, permitted no more than four times daily with at least 60 minutes between excursions.
Ceiling Exposure Limit
A concentration that must never be exceeded at any point during the work shift, even instantaneously. Ceiling values govern fast-acting substances for which an 8-hour average is inadequate protection.
ppm to mg/m3 Conversion
At 25 degrees Celsius and one atmosphere, mg/m3 equals ppm multiplied by molecular weight and divided by 24.45. At 0 degrees Celsius the molar volume constant is 22.4 instead.
Noise Dose Formula
D equals 100 times the sum of exposure time at each noise level divided by the time allowed at that level. A dose above 100 percent exceeds the permissible exposure limit.
OSHA Noise Exchange Rate
OSHA uses a 5-decibel exchange rate, so each 5 dBA increase halves the permissible exposure time: 90 dBA for 8 hours, 95 dBA for 4 hours. NIOSH uses 3 dB.
Hearing Conservation Action Level
A hearing conservation program is required when noise exposure equals or exceeds the 85 dBA action level as an 8-hour TWA, including monitoring, audiometric testing, hearing protection, and training.
Oxygen Deficient Atmosphere
An atmosphere containing less than 19.5 percent oxygen by volume. Confined space entry requires pre-entry and continuous monitoring; concentrations above 23.5 percent are oxygen enriched.
Permit-Required Confined Space
A space with limited entry and exit, not designed for continuous occupancy, that contains a hazardous atmosphere, engulfment potential, entrapment configuration, or other recognized serious hazard. Entry requires a permit.
Excavation Protective System Threshold
Excavations 5 feet or deeper need a protective system unless a competent person finds no collapse indication. At 4 feet, a means of egress within 25 feet of lateral travel is required.
Fall Protection Trigger Heights
Fall protection is required at 6 feet in construction, 4 feet in general industry, and 10 feet on scaffolds. Guardrails, safety nets, or personal fall arrest systems are acceptable controls.
Lockout Tagout Verification
29 CFR 1910.147 requires the authorized employee to verify de-energization after applying locks and tags, normally by attempting startup or testing for zero energy state.
Job Hazard Analysis Steps
Select the job, break it into sequential steps, identify hazards at each step, and determine controls. Results are documented and communicated to the workers who perform the task.
HAZOP Guide Words
A process hazard method that applies words such as no, more, less, reverse, part of, and as well as to process parameters to systematically find deviations from design intent.
Risk Score Calculation
Risk equals likelihood multiplied by severity. The score is plotted on a risk matrix to rank hazards and set the priority and urgency of control measures.
Fire Tetrahedron
Four elements are needed for combustion: fuel, oxygen, heat, and a self-sustaining chemical chain reaction. Removing any one element extinguishes the fire.
Class C Fire
A fire involving energized electrical equipment. Carbon dioxide and dry chemical extinguishers are used; water must not be applied until the circuit is de-energized.
PASS Technique
Pull the pin, Aim at the base of the fire, Squeeze the handle, Sweep side to side. Portable extinguishers are used only on incipient-stage fires by trained employees.
Class A Extinguisher Distance
OSHA requires Class A extinguishers placed so no employee travels more than 75 feet to reach one. Class B spacing is 30 to 50 feet depending on hazard.
Written EAP Threshold
29 CFR 1910.38 requires a written emergency action plan when 11 or more employees are present at the site. Smaller employers may communicate the plan orally.
Exit Route Dimensions
Exit routes must be at least 28 inches wide at all points and kept unobstructed. Emergency lighting must function during power loss, with NFPA 101 setting a 90-minute minimum.
RCRA Ignitability Characteristic
A hazardous waste characteristic defined by a flash point below 140 degrees Fahrenheit, or by being spontaneously combustible, an ignitable compressed gas, or an oxidizer.
RCRA Corrosivity Characteristic
A hazardous waste characteristic defined by an aqueous pH of 2 or less, or 12.5 or greater, or by the ability to corrode steel faster than 6.35 millimeters per year.
Large Quantity Generator
A RCRA generator producing 1,000 kilograms or more of hazardous waste per month, or more than 1 kilogram of acutely hazardous waste, limited to 90 days on-site accumulation.
CERCLA Reportable Quantity
Under CERCLA, a release of a hazardous substance equal to or greater than its assigned reportable quantity must be reported immediately to the National Response Center.
Tier II Report Deadline
Under EPCRA Section 312, facilities storing hazardous chemicals at or above threshold quantities must submit a Tier II inventory report to state and local agencies by March 1 annually.