OPTE study materials
OPTE study resources

OPTE flashcards

OPTE · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Vergence formula
L = n/l, where n is refractive index and l is distance in meters. Diverging light has negative vergence and converging light positive; this quantity drives thin-lens calculations.
Thin lens equation
U + F = V: object vergence plus lens power equals image vergence. Image distance is n'/V; a positive V forms a real image on the emergent side.
Prism diopter definition
One prism diopter displaces an object 1 cm at 1 m. Deviation δ in prism diopters equals 100 times tan of the deviation angle in degrees.
Corneal endothelial pump
The endothelium actively removes fluid from the stroma, maintaining corneal deturgescence. Human endothelial cells do not regenerate; loss causes edema and reduced clarity.
Aqueous humor outflow pathways
Aqueous leaves the anterior chamber mainly through the trabecular meshwork and Schlemm canal, with a smaller uveoscleral route. Outflow obstruction raises intraocular pressure.
Foveal cone density
The foveola contains the highest cone density, roughly 150,000–200,000 per square millimeter, with no rods and no overlying vessels, supporting maximum acuity.
Spherical equivalent
Sphere plus half the cylinder power. A prescription of −2.00/−1.00×180 has a spherical equivalent of −2.50 diopters, useful for estimating overall refractive error.
Jackson cross-cylinder technique
A cross-cylinder with axes at 45 degrees to the tested meridians refines astigmatism. Flip to compare clarity, adjust axis first, then cylinder power in 0.25 D steps.
Duochrome test principle
Red and green wavelengths focus at different positions due to chromatic aberration. With best sphere, both appear equally clear; red clearer means add minus, green clearer means add plus.
Vertex distance compensation
When the refracting and fitting vertex distances differ, adjust power with Fc = F/(1 − dF). Minus lenses gain plus power as they move closer to the eye.
Prentice's rule
Prism in diopters equals decentration in centimeters multiplied by lens power in diopters. A −4.00 D lens decentered 3 mm induces 1.2 prism diopters.
Abbe value and chromatic aberration
Abbe value measures dispersion; lower values produce more chromatic aberration. High-index materials reduce lens thickness but typically lower Abbe value.
RGP fluorescein pattern
Fluorescein evaluation shows apical clearance, mid-peripheral alignment, and edge lift. Excessive central pooling indicates a steep fit; touch indicates a flat fit.
Dk/t oxygen requirement
Dk/t expresses oxygen transmissibility. Daily wear needs about 24 and extended wear about 87 in standard units; silicone hydrogels exceed these values comfortably.
Toric lens rotation rule
Assess rotation with slit lamp and axis marks, then apply LARS: left add, right subtract. Rotate the prescribed axis in the direction of lens rotation.
Cyclopentolate versus tropicamide
Cyclopentolate 1% gives stronger cycloplegia lasting about 24 hours. Tropicamide 0.5–1% gives shorter mydriasis and weaker cycloplegia, useful for screening.
Fluorescein staining
Sodium fluorescein stains areas of corneal epithelial loss. Cobalt blue excitation makes defects visible; it also assesses tear breakup time and contact lens fit.
Timolol mechanism
Timolol, a topical beta-blocker, lowers intraocular pressure by reducing aqueous production. It is contraindicated in asthma, bradycardia, and heart block.
Hirschberg test
Corneal light reflex decentration estimates deviation: 1 mm equals roughly 7 degrees or 15 prism diopters. The reflex appears displaced opposite the direction of strabismus.
AC/A ratio
Accommodative convergence per diopter of accommodation, normally 4–6 prism diopters per diopter. High ratios suggest convergence excess; low ratios suggest divergence excess.
Alternate cover test
Alternating cover breaks fusion and reveals the total deviation, including latent phoria. The prism alternate cover test measures the magnitude until movement reverses.
Glaucomatous disc signs
Cupping greater than 0.6, rim thinning, disc hemorrhage, and nerve fiber layer loss suggest glaucoma. Correlate with intraocular pressure and visual field defects.
Keratoconus signs
Inferior corneal steepening, irregular astigmatism, Vogt striae, and Fleischer ring indicate keratoconus. Topography confirms and monitors progression for crosslinking decisions.
Anterior uveitis findings
Cells and flare in the anterior chamber, photophobia, ciliary flush, and miosis characterize anterior uveitis. Topical steroids and cycloplegics are standard treatment.
Goldmann applanation principle
A 3.06 mm diameter probe applanates the cornea; force converts directly to pressure. Central corneal thickness affects accuracy, with thinner corneas underestimating pressure.
Pinhole test
A pinhole reduces blur circles from refractive error, improving acuity in uncorrected ametropia. Failure to improve suggests media opacity or retinal or neural disease.
Indirect ophthalmoscopy
A condensing lens with a head-mounted or handheld scope provides a magnified, inverted, stereoscopic view of the peripheral retina, useful for detecting tears and detachments.
Visual field reliability indices
Fixation losses below 20 percent and false positive and negative rates below 33 percent indicate a reliable field. Unreliable fields should be repeated before interpretation.
Informed consent elements
Disclose the diagnosis, proposed procedure, alternatives, material risks, and expected outcome. Document the discussion and the patient's agreement in the record.
Record retention
Retain clinical records for the period required by law, often 7–10 years and longer for minors. Records must be legible, dated, and include advice given.
Scope of practice
Professionals must limit care to procedures permitted by licensure and their training. Refer patients when a condition falls outside that competence.
Patient abandonment
Terminating care without reasonable notice or transfer opportunity constitutes abandonment. Provide records on request and document the transfer arrangement.