- OSHA general duty clause
- Section 5(a)(1) of the OSH Act requires each employer to furnish a workplace free from recognized hazards that are causing or likely to cause death or serious physical harm.
- Fatality reporting time limit
- An employer must report a work-related fatality to OSHA within 8 hours of learning of it, by telephone or online to the nearest OSHA office.
- Hospitalization reporting deadline
- Work-related in-patient hospitalizations, amputations, and losses of an eye must be reported to OSHA within 24 hours of the employer learning of the event.
- OSHA inspection priority order
- OSHA ranks inspections as imminent danger first, then fatality or catastrophe, then valid employee complaints and referrals, then programmed high-hazard inspections, then follow-up and monitoring visits.
- Retaliation complaint filing window
- Under Section 11(c) of the OSH Act, an employee who believes they were retaliated against for exercising safety rights must file a complaint with OSHA within 30 days.
- Injury log entry timeframe
- Employers required to keep OSHA records must enter each recordable injury or illness on the OSHA 300 Log within 7 calendar days of learning of the case.
- OSHA 300A posting period
- The annual summary of work-related injuries and illnesses, OSHA Form 300A, must be posted in a visible location from February 1 through April 30 of the following year.
- Who pays for PPE
- Employers must provide, at no cost to employees, all personal protective equipment required by OSHA standards, with narrow exceptions such as non-specialty safety-toe footwear and prescription safety eyewear worn off the job.
- Citation contest deadline
- An employer who disagrees with an OSHA citation must file a written Notice of Contest with the OSHA area director within 15 working days of receiving the citation.
- Fall protection trigger height
- In construction, conventional fall protection such as guardrails, safety nets, or personal fall arrest is required when employees work 6 feet or more above a lower level.
- Scaffold fall protection threshold
- Employees working on scaffolds more than 10 feet above a lower level must be protected by guardrail systems or personal fall arrest systems under 29 CFR 1926.451.
- Steel erection fall protection height
- During steel erection, fall protection is required at 15 feet above a lower level, with specific exceptions for connectors and deckers under 29 CFR 1926.760.
- Guardrail height requirement
- Top rails of guardrail systems must be 42 inches plus or minus 3 inches above the walking surface, with midrails near 21 inches and toe boards at least 3.5 inches high.
- Fall arrest anchor strength
- Personal fall arrest anchors must support at least 5,000 pounds per employee attached, or be designed under a qualified person's supervision with a safety factor of at least two.
- Maximum free fall distance
- A personal fall arrest system must limit free fall to 6 feet or less and stop the fall within a deceleration distance of 3.5 feet, with a rescue plan ready.
- Hole cover requirements
- Holes 2 inches or more in their least dimension must be covered or guarded; covers must be secured, marked HOLE or COVER, and support twice the intended load.
- Warning line distance from edge
- A warning line system must be erected at least 15 feet from the roof edge, at a height between 34 and 39 inches, using line with at least 500 pounds tensile strength.
- Struck-by hazard categories
- Struck-by injuries are grouped as struck by a flying, falling, swinging, or rolling object; controls include toe boards, debris nets, barricades, hard hats, and staying clear of suspended loads.
- Crane swing radius barricade
- Accessible areas within the swing radius of a crane's rotating superstructure must be barricaded so employees cannot be struck or crushed by the rotating equipment.
- Excavation protective system depth
- Excavations 5 feet or deeper require a protective system such as sloping, benching, shoring, or shielding unless a competent person determines there is no cave-in hazard.
- Trench ladder travel distance
- In trenches 4 feet or deeper, a ladder, stairway, or ramp must be provided so that workers travel no more than 25 feet laterally to reach it.
- Spoil pile setback distance
- Excavated material and equipment must be kept at least 2 feet back from the edge of an excavation to reduce cave-in risk from added loads near the edge.
- Crane power line clearance
- Cranes and derricks must keep at least 20 feet from overhead power lines rated up to 350 kV unless the line is de-energized or an insulating barrier is used.
- GFCI requirement on sites
- Construction 120-volt, single-phase, 15- and 20-ampere receptacles must have ground-fault circuit interrupter protection or be covered by an assured equipment grounding conductor program.
- HazCom safety data sheets
- Employers must obtain or develop a safety data sheet for each hazardous chemical in the workplace and keep it readily accessible to employees on each work shift.
- Extension ladder 4-to-1 rule
- An extension ladder must be set with its base 1 foot out from the wall for every 4 feet of working length to the upper support point.
- Ladder extension above landing
- A ladder used for access must extend at least 3 feet above the upper landing surface, and its top must be secured before the ladder is used.
- Scaffold load capacity
- Scaffolds must be designed to support at least 4 times the maximum intended load without failure, with platforms fully planked and inspected by a competent person before each shift.
- Silica permissible exposure limit
- The respirable crystalline silica PEL in construction is 50 micrograms per cubic meter as an 8-hour time-weighted average, with an action level of 25 micrograms per cubic meter.
- Silica Table 1 controls
- OSHA's Table 1 lists specified wet-cutting, vacuum, or water-fed tools and work practices that comply with the silica standard without requiring separate exposure monitoring.
- Confined space attendant duty
- Under 29 CFR 1926 Subpart AA, an attendant remains outside the permit space, monitors entrants, keeps an accurate count, and summons rescue without entering the space.
- Call 811 before digging
- Excavators must determine the location of underground utility installations before opening an excavation; calling 811 arranges free marking of buried utility lines.