PE Nuclear flashcards
PE Nuclear · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Pressurizer
- A PWR vessel holding both steam and water that maintains reactor coolant system pressure using electrical heaters and spray, and provides surge volume to limit pressure swings.
- Steam generator
- A PWR heat exchanger in which hot primary coolant boils secondary water; the tubes are the barrier between radioactive primary fluid and the non-radioactive steam system, so tube leaks are closely monitored.
- ECCS accumulator
- A passive nitrogen-pressurized tank of borated water that injects into the PWR cold legs once reactor coolant pressure drops below its check valve setpoint during a loss-of-coolant accident.
- Main steam isolation valve
- A valve that closes to isolate the main steam line on a safety injection or high-radiation signal, preventing an uncontrolled reactor cooldown that would insert positive reactivity.
- Effective multiplication factor
- The ratio of neutrons produced in one generation to neutrons lost in the preceding generation; k equal to 1 is critical, below 1 subcritical, and above 1 supercritical.
- Delayed neutrons
- Neutrons emitted seconds to minutes after fission from decaying precursors; they constitute about 0.65 percent of U-235 fission neutrons and give the reactor a controllable response time.
- Six-factor formula
- The expression k-infinity equals epsilon times p times f times eta; these four factors account for fast fission, resonance escape, thermal utilization, and neutron reproduction in a thermal lattice.
- Xenon-135
- The strongest fission-product poison in thermal reactors, with a very large thermal absorption cross section; its iodine precursor causes a reactivity peak roughly 8 to 10 hours after shutdown.
- Critical heat flux
- The heat flux at which a boiling surface transitions from efficient nucleate boiling to film boiling, sharply reducing heat transfer and risking cladding overheating or failure.
- Departure from nucleate boiling
- The PWR thermal limit defined by critical heat flux; the ratio of CHF to local heat flux must stay above the design limit to protect fuel cladding.
- Decay heat
- Residual power generated by radioactive decay of fission products after shutdown; about 6.5 percent of full power one second later and still about 1 percent after an hour.
- Reynolds number
- A dimensionless group equal to density times velocity times diameter divided by viscosity; it determines whether pipe flow is laminar or turbulent and guides heat transfer correlation selection.
- Sievert
- The SI unit of equivalent and effective dose, equal to one joule per kilogram weighted for radiation type and tissue; one sievert equals 100 rem.
- ALARA
- The principle of keeping radiation doses as low as reasonably achievable, weighing economics, available technology, and social factors; a written program is required by 10 CFR 20.1101.
- Half-value layer
- The thickness of a shielding material that reduces photon intensity by half; it equals the natural logarithm of two divided by the linear attenuation coefficient.
- Occupational dose limit
- The US annual limit of 50 millisievert total effective dose equivalent under 10 CFR 20.1201, with separate limits for lens dose and extremity dose.
- Separative work unit
- A measure of the effort required to raise uranium enrichment; the amount depends on the feed, product, and tails assays rather than on the mass of uranium processed.
- PUREX process
- A solvent extraction method using tributyl phosphate in an organic diluent to separate uranium and plutonium from fission products in dissolved irradiated fuel.
- Vitrification
- Conversion of high-level radioactive liquid waste into a borosilicate glass matrix, producing a durable, leach-resistant solid suitable for long-term geologic disposal.
- Spent fuel pool
- A water-filled storage basin that removes decay heat through heat exchangers, shields workers from radiation, and uses dissolved boron and geometry to keep fuel subcritical.
- Single failure criterion
- The requirement that a safety system still perform its function assuming the worst single component failure, combined with the design-basis event being analyzed.
- General Design Criteria
- Appendix A to 10 CFR 50, containing criteria that establish minimum design requirements for nuclear power plant structures, systems, and components important to safety.
- LOCA acceptance criteria
- Under 10 CFR 50.46: peak clad temperature no more than 2200 F, clad oxidation no more than 17 percent, hydrogen generation no more than 1 percent, coolable geometry, and long-term cooling.
- Emergency planning zone
- The area around a nuclear plant, typically 10 miles for plume exposure, for which offsite notification, evacuation, sheltering, and protective action planning must be established.
- Limiting condition for operation
- A technical specification requirement defining the minimum equipment and performance needed for safe operation, together with the required actions and completion times if it is not met.
- Surveillance test
- A periodic test that demonstrates a safety-related system or component still meets its technical specification performance requirements, such as response time, flow, or stroke time.
- Refueling outage
- A planned shutdown to replace fuel and perform maintenance; core alterations demand a senior reactor operator, verified boron concentration, and adherence to the criticality checklist.
- Type A leak test
- An integrated containment leak rate test performed at design pressure to confirm that overall containment leakage does not exceed the technical specification acceptance limit.
- Zircaloy
- A zirconium alloy used for fuel cladding because it absorbs few neutrons and resists corrosion; at high temperature it reacts with steam exothermically and releases hydrogen.
- Sensitization
- Chromium carbide precipitation along grain boundaries in austenitic stainless steel after prolonged heating in a critical temperature range, leaving it prone to intergranular stress corrosion cracking.
- Reactor protection system
- Redundant, fail-safe instrumentation and logic that automatically trips the reactor when monitored parameters exceed their trip setpoints, typically using two-out-of-four coincidence.
- Fission chamber
- A neutron detector coated with fissile material that produces measurable ionization from fission fragments, used in source and intermediate range channels with good discrimination against gamma background.