MELE key terms
MELE · Get comfortable with the vocabulary.
- Antibody screen (indirect antiglobulin test)
- Related: Alloantibody, Antibody titration, Crossmatch
A test that mixes a patient's serum with reagent red cells and anti-human globulin to detect unexpected antibodies against red cell antigens before transfusion or during pregnancy.
- Alloantibody
- Related: Antibody screen (indirect antiglobulin test), Crossmatch, Antibody titration
An antibody formed after exposure to foreign red cell antigens through transfusion or pregnancy, directed against antigens the person lacks; unlike autoantibodies, it reacts with donor cells.
- Crossmatch
- Related: Antibody screen (indirect antiglobulin test), Alloantibody, ABO discrepancy
The compatibility test that mixes recipient serum with donor red cells, with or without anti-human globulin, to confirm no clinically significant incompatibility exists before transfusion.
- ABO discrepancy
- Related: Crossmatch, Antibody titration
A mismatch between forward (cell) and reverse (serum) ABO typing results, caused by weak subgroups, missing antibodies, extra antibodies, or technical error, requiring resolution before transfusion.
- Antibody titration
- Related: Alloantibody, Antibody screen (indirect antiglobulin test)
Serial dilution of serum to measure antibody strength, reported as the highest dilution showing reactivity; used for prenatal anti-D monitoring and for assessing ABO-incompatible transplant risk.
- Direct antiglobulin test (DAT)
- Related: Alloantibody, Antibody screen (indirect antiglobulin test)
A test detecting antibody or complement coating a patient's own red cells in vivo, using anti-human globulin; positive results suggest autoimmune hemolysis, drug-induced hemolysis, or hemolytic disease of the newborn.
- Reference interval
- Related: Analytical sensitivity, Delta check
The central range of results, usually covering the middle 95% of a healthy reference population, against which a patient result is compared to flag possible abnormality.
- Analytical sensitivity
- Related: Reference interval, Interference (assay)
The smallest amount of analyte a method can reliably distinguish from zero, often expressed as the limit of detection; distinct from functional sensitivity and from clinical sensitivity.
- Interference (assay)
- Related: Analytical sensitivity, Delta check
A substance or condition in the sample, such as hemolysis, lipemia, icterus, or a cross-reacting drug, that alters measured analyte concentration and biases the result.
- Delta check
- Related: Reference interval, Interference (assay)
A quality rule that compares a patient's current result with a previous result and flags differences exceeding a set limit, catching specimen mix-ups, mislabeling, and acute changes.
- Anion gap
- Related: Osmolal gap
The calculated difference between measured cations and anions, usually sodium minus chloride and bicarbonate; an elevated value suggests unmeasured anions such as ketoacids, lactate, or toxins.
- Osmolal gap
- Related: Anion gap
The difference between measured osmolality and calculated osmolality; an increased gap indicates unmeasured osmotically active particles such as ethanol, methanol, ethylene glycol, or isopropanol.
- Complete blood count (CBC)
- Related: Mean corpuscular volume (MCV), Reticulocyte count, Peripheral blood smear review
A panel measuring red cell count, hemoglobin, hematocrit, red cell indices, white cell count and differential, and platelet count, used to screen and monitor hematologic and systemic disease.
- Mean corpuscular volume (MCV)
- Related: Complete blood count (CBC), Reticulocyte count
The average volume of a red blood cell, calculated from hematocrit and red cell count; classifies anemia as microcytic, normocytic, or macrocytic and guides further testing.
- Reticulocyte count
- Related: Complete blood count (CBC), Mean corpuscular volume (MCV)
The percentage or absolute number of young red cells still containing RNA, reflecting marrow response; a high count indicates blood loss or hemolysis, a low count suggests production failure.
- Peripheral blood smear review
- Related: Complete blood count (CBC), Reticulocyte count
Microscopic examination of a stained blood film to assess cell morphology, platelet adequacy, and white cell distribution, confirming or explaining automated analyzer findings.
- Minimum inhibitory concentration (MIC)
- Related: Disk diffusion (Kirby-Bauer), Breakpoint
The lowest antimicrobial concentration that visibly inhibits growth of a standardized bacterial inoculum, used to categorize an isolate as susceptible, intermediate, or resistant.
- Disk diffusion (Kirby-Bauer)
- Related: Minimum inhibitory concentration (MIC), Breakpoint
An agar-based susceptibility method in which antibiotic-impregnated disks diffuse into inoculated agar; zone diameters are compared with published breakpoints to categorize susceptibility.
- Breakpoint
- Related: Minimum inhibitory concentration (MIC), Disk diffusion (Kirby-Bauer)
A published concentration or zone-diameter threshold that separates susceptible from resistant organisms for a given drug, organism group, and testing method.
- Selective and differential media
- Related: Colony morphology, Minimum inhibitory concentration (MIC)
Culture media that suppress unwanted organisms and reveal distinguishing biochemical traits, such as MacConkey agar inhibiting gram-positives while differentiating lactose fermenters by colony color.
- Colony morphology
- Related: Selective and differential media
The visible characteristics of a bacterial colony on agar, including size, shape, color, hemolysis, and texture, used with Gram stain to guide identification.
- Enzyme immunoassay (EIA)
- Related: Prozone effect, Seroconversion
A method using an enzyme-linked antibody to detect or quantify antigen or antibody through a color-producing substrate reaction; widely used for screening serology and hormone testing.
- Prozone effect
- Related: Enzyme immunoassay (EIA), Seroconversion
A false-negative or falsely low immunoassay result caused by very high antibody excess, which prevents immune complex lattice formation; resolved by diluting the specimen and retesting.
- Seroconversion
- Related: Enzyme immunoassay (EIA), Prozone effect
The appearance of detectable specific antibody or antigen after infection or vaccination, marked by a change from negative to positive; paired sera showing rising titer support recent infection.
- Specific gravity (urine)
- Related: Urine microscopy, Urinalysis reagent strip
A measure of urine density relative to water, reflecting the kidney's concentrating ability; assessed by refractometry or reagent strip and useful in evaluating hydration and renal function.
- Urine microscopy
- Related: Specific gravity (urine), Urinalysis reagent strip
Examination of urine sediment for cells, casts, crystals, and organisms; findings such as red cell casts localize disease to the kidney and guide diagnosis.
- Urinalysis reagent strip
- Related: Specific gravity (urine), Urine microscopy
A dipstick with reagent pads that change color to screen for pH, protein, glucose, ketones, blood, leukocyte esterase, nitrite, and other analytes; results require confirmation by microscopy.
- Levey-Jennings chart
- Related: Westgard rules, External quality assessment
A control chart plotting quality control values over time with mean and standard deviation limits, making shifts, trends, and random error visible for daily assay monitoring.
- Westgard rules
- Related: Levey-Jennings chart, External quality assessment
Statistical multirule criteria, such as 1-3s, 2-2s, R-4s, and 4-1s, applied to quality control data to decide whether an analytical run should be accepted or rejected.
- External quality assessment
- Related: Levey-Jennings chart, Westgard rules
A program that sends unknown specimens to many laboratories and compares each result with peer or reference values, providing objective evidence of analytical performance.
- Polymerase chain reaction (PCR)
- Related: Cycle threshold (Ct), Contamination control (molecular)
A technique that repeatedly copies a target DNA sequence using primers, nucleotides, and a thermostable polymerase, enabling detection of minute amounts of pathogen or human genetic material.
- Cycle threshold (Ct)
- Related: Polymerase chain reaction (PCR), Contamination control (molecular)
The PCR cycle at which fluorescence first exceeds background; lower values indicate more starting target, while high values near the limit of detection require cautious interpretation.
- Contamination control (molecular)
- Related: Polymerase chain reaction (PCR), Cycle threshold (Ct)
Practices preventing amplicon or specimen carryover from causing false positives, including unidirectional workflow, separate pre- and post-amplification areas, aliquoted reagents, and negative controls.
- Standard precautions
- Related: Biological safety cabinet, Safety data sheet (SDS)
Infection control practices applied to all patients, including hand hygiene, gloves, gowns, masks, and safe sharps handling, based on the assumption that any specimen may carry transmissible agents.
- Biological safety cabinet
- Related: Standard precautions, Safety data sheet (SDS)
A ventilated enclosure using HEPA-filtered airflow to protect workers and the environment, and in some classes the product, when handling infectious aerosols or manipulating cultures.
- Safety data sheet (SDS)
- Related: Standard precautions, Biological safety cabinet
A standardized document supplied with a hazardous chemical that lists hazards, handling precautions, exposure controls, first aid, and spill response, required to be accessible to laboratory staff.