Sanitary Engineer Licensure Exam flashcards
Sanitary Engineer Licensure Exam · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Design period
- The assumed service life used to size a facility. Water treatment plants and transmission mains commonly use 10-20 years; distribution networks 20-30 years; pumps and mechanical equipment 5-10 years.
- Peak hour factor
- Ratio of maximum hourly demand to average daily demand, typically 2.5-3.0 for residential areas. Used to size distribution mains and service connections, not treatment plants.
- Maximum day demand
- Highest 24-hour demand in a year, usually 1.5-2.0 times average day demand. It sets treatment plant and transmission capacity, with fire flow added for main sizing.
- Hazen-Williams formula
- Empirical head loss equation for pressurized pipes: hf = 10.67 L Q^1.852 / (C^1.852 D^4.87) in SI units. The C coefficient ranges near 130-140 for new lined pipe.
- Manning equation
- Open-channel flow formula V = (1/n) R^(2/3) S^(1/2), used to size gravity sewers. Roughness n is about 0.013 for concrete and 0.011-0.012 for plastic pipe.
- Self-cleansing velocity
- Minimum flow velocity that keeps solids moving in a sewer, about 0.6 m/s at design flow and 0.75 m/s where heavy solids occur. Prevents deposition and sulfide generation.
- Minimum sewer diameter
- Smallest permitted public sewer size, usually 200 mm for mains and 150 mm for laterals. Larger diameters reduce blockage risk and allow inspection and cleaning equipment.
- Manhole spacing
- Manholes are required at every change in direction, slope, or diameter and at intervals of roughly 90-150 m on straight runs, to permit access for cleaning and inspection.
- Drop manhole
- A manhole with an internal vertical drop pipe, used where the incoming invert is more than about 0.6 m above the outgoing invert, to prevent splashing and erosion.
- BOD5
- Biochemical oxygen demand measured over five days at 20 degrees C, approximating biodegradable organic content. Domestic sewage is typically 200-220 mg/L; first-order decay applies with k near 0.17 per day.
- Standard-strength wastewater
- Typical untreated domestic sewage composition: BOD5 about 200-220 mg/L, suspended solids 200-240 mg/L, total nitrogen 35-45 mg/L, and total phosphorus 6-10 mg/L.
- Grit chamber velocity
- Chambers are designed to hold a horizontal velocity near 0.3 m/s so dense grit settles while lighter organic solids remain suspended and pass to downstream treatment.
- Primary sedimentation overflow rate
- Design surface overflow rate of 30-50 m3/m2·d at average flow, rising to 80-120 m3/m2·d at peak. Detention time is 1.5-2.5 h, removing 50-65% of suspended solids.
- Food-to-microorganism ratio
- F/M ratio expresses kg BOD5 applied per kg MLSS per day. Conventional activated sludge uses 0.2-0.4 per day; extended aeration uses 0.05-0.15 per day.
- Solids retention time
- Average time solids remain in the aeration system, controlling treatment performance. Conventional plants use 5-15 days; nitrifying or extended aeration plants need 20-30 days.
- MLSS
- Mixed liquor suspended solids, the biomass concentration in an aeration basin, normally maintained at 2,000-4,000 mg/L. It sets the solids loading on secondary clarifiers.
- Secondary clarifier solids loading
- Design parameter for activated sludge clarifiers, about 100-150 kg/m2·d at peak flow. Surface overflow rate is typically 16-32 m3/m2·d with 2-4 h detention.
- Return activated sludge ratio
- Flow of settled sludge returned to the aeration basin, expressed as a fraction of influent flow, usually 0.5-1.5. It maintains the desired MLSS concentration.
- Oxygen demand per BOD removed
- Aeration must supply roughly 1.0-1.4 kg of oxygen per kg of BOD5 removed, plus endogenous respiration demand, which increases with longer solids retention time.
- Trickling filter organic loading
- Low-rate filters receive 0.08-0.4 kg BOD per m3 of media per day; high-rate filters receive 0.4-1.0 kg BOD/m3·d with recirculation to improve distribution and nitrification.
- Sludge thickening
- Gravity thickening of waste sludge at 25-35 kg/m2·d raises solids from about 0.5-1.0% to 4-6%, reducing digester volume. Primary sludge starts at 4-6% solids.
- Anaerobic digestion
- Mesophilic digestion at 30-38 degrees C with 15-30 day retention and volatile solids loading of 0.5-1.5 kg VS/m3·d, destroying 40-60% of volatile solids and producing methane.
- Chlorine CT concept
- Disinfection effectiveness depends on residual concentration times contact time. Required CT rises as temperature falls and as pH rises, because hypochlorous acid dissociates.
- UV disinfection dose
- Ultraviolet light dose of about 30-40 mJ/cm2 is applied to secondary effluent for coliform reduction. Effectiveness depends on low turbidity and proper lamp cleaning.
- Nitrification requirements
- Ammonia oxidation needs solids retention time above about 10 days at 20 degrees C, dissolved oxygen above 2 mg/L, and alkalinity near 7.1 mg as CaCO3 per mg ammonia-N.
- Rapid sand filter rate
- Filtration rate of 4-12 m/h through 0.6-0.9 m of sand with effective size 0.45-0.55 mm. Backwash at 12-15 L/m2·s expands the bed about 20-25%.
- Coagulation velocity gradient
- Rapid mix uses a velocity gradient of 300-1,000 per second for 10-60 seconds; flocculation uses 10-75 per second for 15-30 minutes, tapering downward.
- Alum coagulation pH
- Alum doses of 10-50 mg/L perform best at pH 5.5-7.5, where aluminum hydroxide flocs form. Optimum pH shifts with raw water alkalinity and turbidity.
- Service reservoir capacity
- Storage sized at 25-35% of maximum day demand for equalizing flow, or roughly 15-20% of maximum day demand plus dedicated fire storage where fire flow is required.
- Air gap backflow protection
- A physical separation between supply outlet and the fixture's flood level, giving the highest protection against both backpressure and backsiphonage. Reduced pressure zone assemblies are next.
- Trap seal depth
- The water seal in a plumbing trap, normally 50-100 mm deep. It blocks sewer gas while allowing wastewater flow; improper venting causes seal loss by siphonage.
- Septic tank retention
- Household septic tanks provide 24-48 hours retention with 1,000-2,000 L capacity and store sludge and scum for 1-3 years. Effluent goes to a soil absorption field.