VLE flashcards
VLE · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Backward design sequence
- Start from desired program outcomes, then define acceptable evidence such as assessments, and only then design learning activities and instruction that lead to that evidence.
- Measurable objective components
- A performance stated with an action verb, the conditions under which it occurs, and a criterion such as accuracy or time limit that allows objective judgment of achievement.
- Constructive alignment
- The three-way match among intended learning outcomes, teaching and learning activities, and assessment tasks; misalignment among the three weakens the validity of any claim of competence.
- Criterion-referenced assessment
- Scoring that compares learner performance to a fixed predetermined standard rather than to peers, which is the appropriate model for competency-based laboratory education and certification decisions.
- Item discrimination index
- Computed as the proportion correct in the upper scoring group minus the proportion correct in the lower group; values of 0.30 or higher are generally considered acceptable.
- Formative versus summative
- Formative assessment informs learning and teaching without a grade consequence; summative assessment certifies achievement at the end of instruction. The two serve different decisions.
- Standard precautions scope
- Apply to all blood, body fluids, secretions, excretions, non-intact skin, and mucous membranes regardless of whether infection is suspected or confirmed in the patient.
- Formaldehyde exposure limits
- The eight-hour time-weighted average limit is 0.75 ppm and the short-term exposure limit is 2 ppm; monitoring, labeling, and spill response are required where formaldehyde is used.
- Needlestick immediate actions
- Wash the site with soap and water without squeezing or scrubbing, report immediately, and seek HIV postexposure prophylaxis as soon as possible, ideally within hours of exposure.
- Anemia by MCV
- Microcytic anemia is below 80 fL, normocytic is 80 to 100 fL, and macrocytic exceeds 100 fL; the red cell distribution width helps confirm accompanying anisocytosis.
- Corrected reticulocyte count
- Multiply the reticulocyte percentage by the patient hematocrit divided by the normal hematocrit; this adjusts for anemia severity when judging marrow response.
- EDTA pseudothrombocytopenia
- Platelet clumping caused by EDTA anticoagulant produces a falsely low automated platelet count; repeat in citrate or heparin and examine the stained smear for clumps before reporting.
- PT versus aPTT pathways
- Prothrombin time evaluates the extrinsic and common pathways including factor VII; activated partial thromboplastin time evaluates the intrinsic and common pathways including factors XII, XI, IX, and VIII.
- Beer-Lambert law
- Absorbance equals molar absorptivity times path length times concentration; the relationship is linear only within a limited range, so high results require dilution and reanalysis.
- Anion gap formula
- Sodium minus the sum of chloride and bicarbonate, normally 8 to 12 mmol/L; an elevated gap with metabolic acidosis suggests ketoacidosis, lactic acidosis, renal failure, or toxin.
- Urine nitrite and leukocyte esterase
- A positive nitrite with positive leukocyte esterase at alkaline pH supports urinary tract infection; nitrite-negative results do not exclude infection by organisms that do not reduce nitrate.
- Hyponatremia initial step
- Measure serum osmolality first: low indicates true hypo-osmolar hyponatremia, normal suggests pseudohyponatremia from hyperlipidemia or hyperproteinemia, and high suggests hyperglycemia or mannitol.
- Gram stain mechanism
- Thick peptidoglycan retains the crystal violet-iodine complex after decolorization, giving purple gram-positive cells; the thin layer and outer membrane of gram-negative cells lose it and counterstain pink.
- MacConkey agar interpretation
- Selective for gram-negative bacilli and differential for lactose fermentation; lactose fermenters produce pink colonies, while non-fermenters remain colorless on the medium.
- Coagulase and catalase tests
- Coagulase positivity identifies Staphylococcus aureus among staphylococci; the catalase test separates staphylococci, which are positive, from streptococci, which are negative.
- Ova and parasite collection
- At least three stool specimens collected on separate days are required because parasite shedding is intermittent; preserved specimens retain morphology for later examination.
- Westgard 1-3s rule
- A single control observation exceeding the mean by three standard deviations is rejected; this violation most often indicates random error rather than a systematic shift.
- Westgard 2-2s rule
- Two consecutive control observations exceed the same two-standard-deviation limit, indicating systematic error such as a calibration shift, reagent lot change, or deteriorating control material.
- Coefficient of variation
- Calculated as the standard deviation divided by the mean, multiplied by 100; a lower value indicates better precision of the measurement procedure.
- Sigma metric calculation
- Sigma equals total allowable error minus bias, divided by coefficient of variation; values of six or higher are world class and values below three require corrective action.
- Delta check purpose
- Compares a current patient result with that patient's previous result; a difference exceeding a defined threshold prompts review of specimen identity, integrity, or analytic error before reporting.
- Spectrophotometer light path
- Light travels from source through monochromator or filter, then the cuvette, then the photodetector, and finally the signal processor, which converts transmitted light to absorbance.
- Stray light effect
- Stray light reaching the detector limits absorbance linearity, typically above 2.0 to 2.5 absorbance units, so results beyond that range are unreliable and require dilution.
- Centrifuge balancing rule
- Opposing tubes must be matched by mass, not merely by volume; imbalance causes vibration, rotor damage, and possible release of aerosols from broken tubes.
- HIPAA minimum necessary
- Each use or disclosure of protected health information is limited to the minimum needed for treatment, payment, or operations, except when the patient authorizes broader release.
- Informed consent elements
- Capacity to decide, disclosure of risks and benefits and alternatives, comprehension of that information, and voluntariness; a signed form alone does not establish valid consent.
- SBAR handoff structure
- Situation, Background, Assessment, and Recommendation; the recommendation is stated explicitly and the receiver repeats back critical information to close the communication loop.
- Critical value read-back
- Notify the responsible caregiver within the defined time and document the value, recipient, time, and read-back confirmation; closed-loop communication verifies the message was received accurately.