Certified Passive House Designer / Consultant flashcards
Certified Passive House Designer / Consultant · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Heating demand limit
- Maximum allowed annual heating demand for Passive House certification is 15 kWh per square meter of treated floor area per year, calculated using the PHPP method.
- Primary energy limit
- Passive House certification requires primary energy demand not exceeding 60 kWh per square meter of treated floor area per year, including all energy uses.
- Airtightness criterion
- The building envelope must achieve an n50 value of 0.6 air changes per hour or less at 50 Pa pressure difference, verified by a pressurization test.
- Thermal comfort criterion
- Operative temperature must not exceed 25 degrees Celsius for more than 10 percent of hours during the cooling season, as verified in PHPP.
- U-value formula
- U-value equals the reciprocal of the sum of internal surface resistance, layer resistances (thickness divided by thermal conductivity), and external surface resistance.
- Thermal bridge penalty
- The additional heat loss due to thermal bridges is calculated as the linear thermal transmittance multiplied by the length of the bridge divided by the area.
- Airtightness layer continuity
- The airtight layer must be continuous and seal all penetrations, including cables and pipes, using gaskets and membranes to avoid leaks.
- Insulation thickness for U-0.15
- To achieve a U-value of 0.15 watts per square meter kelvin, typical insulation thickness is 20 to 30 centimeters for thermal conductivity 0.035 to 0.040.
- Window U-value formula
- Window U-value is calculated as the area-weighted average of glazing and frame U-values plus the linear thermal bridge at the glazing edge, divided by total area.
- Triple glazing requirements
- For Passive House certification, glazing U-value should be 0.8 watts per square meter kelvin or lower, with a frame U-value of 1.0 or lower.
- Solar heat gain coefficient
- The solar heat gain coefficient (g-value) indicates the fraction of solar radiation admitted through glazing; it should be high for passive heating and low for cooling.
- Window installation position
- Windows should be installed within the insulation layer, with airtight connections and thermal breaks at the frame to minimize thermal bridging.
- Ventilation rate
- Minimum ventilation rate for Passive House is typically 0.3 air changes per hour based on occupancy, ensuring indoor air quality while minimizing heat loss.
- Heat recovery efficiency
- Passive House ventilation systems require a heat recovery efficiency of at least 75 percent, achieved with a counterflow heat exchanger.
- Duct design pressure drop
- Ventilation ducts should be designed for low pressure drops, typically below 100 pascals, using smooth ducts and avoiding sharp bends to reduce fan energy.
- Summer comfort strategy
- To avoid overheating, use external shading, night ventilation, and high thermal mass; PHPP verifies that overheating hours remain below 10 percent.
- Heating load limit
- The maximum heating load for Passive House certification is 10 watts per square meter of treated floor area, ensuring minimal heating system size.
- Domestic hot water demand
- Typical domestic hot water demand is 30 to 60 liters per person per day at 60 degrees Celsius, often met by solar thermal or heat pumps.
- Heat pump COP
- For Passive House, heat pumps should have a coefficient of performance of at least 3.5 to ensure efficient heating and domestic hot water generation.
- Renewable energy integration
- Renewable energy sources such as solar thermal and photovoltaics can reduce primary energy demand and are accounted for in the PHPP calculation.
- Heating demand formula
- Annual heating demand is the sum of transmission losses, ventilation losses, minus solar gains and internal gains, calculated monthly in PHPP.
- Primary energy factor
- Primary energy factor converts final energy to primary energy; for grid electricity it is typically 1.8 to 2.4, while for renewables it can be near zero.
- PHPP verification criteria
- PHPP verification requires heating demand of 15 kWh per square meter per year or less, primary energy of 60 or less, and airtightness of 0.6 or less.
- Summertime overheating check
- PHPP verifies that the frequency of operative temperatures above 25 degrees Celsius does not exceed 10 percent of hours during the cooling period.
- Life-cycle cost analysis
- Economic assessment of Passive House should consider life-cycle costs, including construction, energy, maintenance, and subsidies, compared to conventional buildings.
- Independent quality assurance
- An independent PHI-certified verifier checks the PHPP, construction documents, and on-site work to ensure compliance with Passive House criteria.
- Construction supervision stages
- On-site inspections should occur at key stages: airtightness layer installation, insulation placement, window installation, and ventilation system commissioning.
- Commissioning airtightness test
- A pressurization test measures the n50 value; a trained technician conducts it and provides a report including leakage locations and the measured value.
- Ventilation commissioning
- Commissioning involves measuring air flows at each terminal, adjusting dampers to design values, and verifying heat recovery efficiency and system balance.
- Certification documentation
- Certification requires submission of PHPP, as-built drawings, airtightness test report, and commissioning report to PHI or an accredited certifier.
- Certification validity
- Passive House certification is valid for five years; re-certification may require updated documentation and verification of continued compliance.
- Thermal bridge avoidance
- Avoid thermal bridges by wrapping insulation continuously around corners and using thermal break elements for balconies and other penetrations.